Exciting enhancements are coming soon to eCode360! Learn more 🡪
Township of Whitpain, PA
Montgomery County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
The requirements of § A167-6 shall be deemed to be fulfilled to the minimum extent when a drilled well has been installed in conformity with the applicable construction set forth in Table 1.[1]
A. 
Well-casing pipe. The minimum standard of quality for casing shall be new steel or wrought iron equivalent to full-weight standard pipe in sizes eight inches and over, and pipe for sizes under eight inches, full-weight standard.
B. 
All connections to a well casing and all joints in the casing itself must be assembled pressure-tight, made up of correctly mated threaded pipe fittings, welded connections, sanitary well seals or other approved connections.
C. 
Well-casing pipe shall be driven or installed so that no injury affecting the safety of the water supply results.
D. 
Upon completion of drilling, the well shall be equipped with a suitable watertight cap or plug to protect the well from tampering or from the entrance of foreign matter.
E. 
(Also see § A167-12.) Provision for sounding water levels and water level indicating device.
(1) 
A well used for domestic purposes shall be equipped with an access opening extending at least to ground level to permit sounding of water level in the well. This opening shall be three-eighths-inch or larger pipe, properly sealed with a watertight cap or plug to prevent access of surface water. This access pipe may be a part of the well venting system.
(2) 
A well used for commercial or industrial purposes shall, in addition to the above, be equipped with an approved water level indicating device.
The construction of flowing wells shall comply with the minimum requirements of § A167-9.
A. 
Every practicable effort shall be made to extend the watertight (cased and cement-grouted) construction into the upper confining bed of the artesian basin.
B. 
When it is impractical to extend the watertight construction indicated in Subsection A, an adequate packer shall be set and maintained in the confining bed with a flow pipe extending therefrom to a point at least one foot above the established grade.
A. 
Bored-type wells. Construction of this type well shall be subject to regulations specified by the Whitpain Township Board of Supervisors at the time of application.
B. 
Driven-point wells. Construction of this type well shall be subject to regulations specified by the Whitpain Township Board at the time application is made.
C. 
Dug-type wells. Construction of this type well shall be subject to regulations specified by the Whitpain Township Board at the time of application.
D. 
Conversion of dug-type wells. Construction of this type well shall be subject to regulations specified by the Whitpain Township Board at the time of application and in this subsection:
(1) 
Preparation for deepening. Any sediment or debris in the bottom of the dug well shall be removed. The bottom shall be disinfected by distributing a chlorine solution over the bottom or adding such solution to water in the well. A concentration of 200 parts per million of chlorine should be attained for disinfection.
(2) 
Applicability to drilled-type construction. Deepening construction done by drilling methods shall conform to applicable conditions of § A167-9. Existing dug- and drilled-type wells shall be effectively protected against entrance of surface and near-surface water by extending the casing pipe of the drilled part of the well to the surface and filling the dug part of the well with puddled clay or equally impermeable material.