On any corner lot, no wall, fence or other structure shall be erected or altered and no hedge, tree, shrub or other growth shall be maintained which may cause danger to traffic on a street by obscuring the view.
No fence or wall (except a retaining wall or a wall of a building permitted under the terms of this chapter) over five feet in height shall be erected within any of the open space required by this chapter unless that portion of the fence or wall which exceeds five feet in height shall contain openings wherein equal to 50% or more of the area of said portion of the fence or wall.
In the case of any use other than a single-family or two-family dwelling, all trash, rubbish and debris of every kind and nature shall be stored in properly closed verminproof containers within an enclosure until such time as it shall be scheduled for collection and disposal and shall be collected and disposed of as often as may be necessary under the particular circumstances.
An indicated in the regulations for certain multiple-family residential, commercial and industrial zoning districts, general requirements for protection from such catastrophes as fire, explosion or their results are given below.
A. 
Water supply.
(1) 
The site must be in an approved fire-protected district (the definition for which states the required adequacy of the water supply and water storage facility in terms of rate of flow and water pressure). See § 210-4.
(2) 
The submitted plan shall show existing mains and water supplies in the immediate area, together with proposed mains and water supplies to provide adequate fire protection to the proposed site.
(3) 
No structure needing fire protection shall be located more than 600 feet from a duly dedicated, accessible and improved public street.
B. 
Fire lanes.
(1) 
Fire lane. No structure to be protected shall be located more than 150 feet from a duly improved and accessible fire lane.
(2) 
Fire lanes shall consist of an all-weather and well-drained surface cartway and shall conform to Township prescribed standards and specifications for new road construction in residential zoning districts except that the cartway must be 20 feet, but does not have to have rolled gutters.
(3) 
The extension of fire lanes shall begin from one or more existing and improved public streets.
(4) 
Fire lanes which curve, turn or change directions shall have a minimum radius of 55 feet at the inside edge of pavement. Fire lanes containing reverse curves shall have a minimum center line tangent length of 50 feet between curves.
(5) 
Dead-end fire lanes shall be terminated with an unobstructed vehicular turnaround or cul-de-sac with a minimum right-of-way radius of 45 feet and shall have a minimum surfaced radius of 35 feet. Dead-end fire lanes shall have a maximum length of 400 feet.
(6) 
The location of fire lanes shall conform to plans for the extension of street, sanitary sewers, water mains, storm sewers and other drainage facilities and public utilities as contained in this chapter and other ordinances of Concord Township and shall provide adequate access to buildings by firemen and other emergency services.