Town of Warwick, NY
Orange County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
[Amended 6-23-1988 by L.L. No. 1-1988]
This chapter shall apply to all water districts of the Town of Warwick now or hereafter established and to the customers thereof. No water service connections or facilities shall be made or installed except in conformity with the provisions of this chapter.
As used in this chapter, unless the context or subject matter otherwise requires, the following terms shall have the meanings indicated:
COMMERCIAL PROPERTY
Any property which shall not come within the definition of "residence property."
CONSUMER
The owner or owners of premises supplied with water from the system.
DISTRICT
One of the water districts duly established by the Town Board pursuant to Article 12 of the Town Law.
OPERATOR
The person, company or agency designated by the Town Board to provide hands-on operation of the district system, inspect and supervise the installation of connections to the system, provide meter readings, perform routine maintenance and perform housekeeping and laboratory work.
RESIDENCE PROPERTY
A house, apartment, cabin, cottage or any other dwelling unit occupied or capable of being occupied as unrelated eating and sleeping quarters for one or more persons.
SYSTEM
The wells, pumping apparatus, reservoirs and reservoir sites, water mains, infiltration galleries, pipes and all appurtenances of the district water supply and distribution facilities.
A. 
Taps and service pipes. All taps on the mains, whether above or below ground, service connections and service pipes from the main, including the curb valve and box for the same, shall be made, put in and installed at the expense of the consumer. Service pipes will be installed by the district from the main to a point at the property line of the consumer or 12 feet from the edge of the pavement or to any building structure or obstruction constructed by the consumer on the highway, whichever distance shall be the least.
B. 
Connections and tampering with main. No person shall make any tap on the main, either above or below ground, or make any connection with the service pipe extending the main to the curb valve except the operator or employees of the district, nor shall any person tamper with, disturb, destroy or in any manner interfere with any pipes, mains, connections or other property of the district.
C. 
Specifications. All service lines hereafter installed from the curb stop to the building and/or meter shall be of Type K soft copper tubing, and only flare fittings of a type approved by the district are to be used and the same shall be furnished and laid at the expense of the consumer.
D. 
Meter connections. Where meters are installed, no connection shall be made to the service pipe between the curb valve and the meter.
E. 
Depth of service pipes. All service pipes shall be laid and maintained at a depth of not less than four feet below the surface of the ground to within 12 inches inside the cellar foundation and up to the water meter.
F. 
Rock excavation. In case of rock excavation or rocky terrain, a sand ballast of four inches shall be placed below the service line and covered with no less than 12 inches of clean sand. No trench shall be backfilled on any service line until the same has been inspected by the district or its representative and tested for leaks, and no water service will be furnished until the district or its representative has made such inspection.
G. 
Danger of freezing; special requirements. If the district shall determine and decide that there is inadequate heating in any cellar served by year-round service so that there is a possibility that the pipes may freeze, it may, in its discretion, require underground meter installation on the building side of the curb stop, which underground meter shall be installed at the expense of the consumer, and no further service shall be provided until such underground meter is installed.
H. 
Repair of service pipes; leaks. All service pipes from the curb box to the building and/or meter shall be maintained and kept in repair and free from leaks at the expense of the consumer. If a leak is found in the service pipe or in the building, the district shall have the right to discontinue the supply of water and to collect the expense of shutting off the water, and water shall not then be supplied to the premises until all leaks are repaired and the charge for turning off and turning on the water shall be paid in full.
I. 
Curb valve. No person except the operator or employees of the district shall turn off or turn on the water in any service pipe at the curb valve.
J. 
Aboveground service piping. On any aboveground service piping, a supplementary valve shall be installed on the service line as near the building as possible and accessible at all times.
No connection to any other source of supply of water shall be made or maintained to any pipe or plumbing fixtures that may be connected to the system of the district.
A. 
The operator or any employee of the district shall have free access to any premises supplied by water from the system at all reasonable hours of the day for the purpose of inspecting the condition and use of all plumbing and service pipes and of reading the meter, making repairs or replacing meters.
B. 
Final reading fee:
[Added 2-13-2003]
(1) 
Metered: $40.
(2) 
Nonmetered: $25.
No person except the operator or employee of the district or any member of a duly organized fire company shall take water from any fire hydrant or shall operate, use or disturb any hydrant.
A. 
Meters and connections will be furnished and installed by the district, provided that proper openings and fittings, such as valves, etc., have been installed by the consumer at his expense to the satisfaction of the district.
B. 
All meters shall remain the property of the district.
C. 
The consumer shall bear and pay all expenses of repairs to meters occasioned by fire, frost, accident or misuse.
D. 
The consumer shall be liable for the loss of a meter from any cause. Amount of liability will be determined by the cost of the meter at the time of replacement.
E. 
No person other than the operator or employee of the district shall install, remove, interfere or tamper with any meter or any dials thereof. If a meter fails to properly register the water consumption, it will be changed or repaired, and the consumer will be charged according to the consumption during the corresponding period in the previous year. Where a water meter fails to register the correct quantity of water delivered through it or where it otherwise becomes out of order or in need of repair, notice thereof shall be given to the operator and another meter will then be loaned and installed during the time required for testing and repair. The operator will cause the meter to be tested, and if the meter upon testing is found to be registering over 3% more water than actually passes through it, no charge will be made for the test; otherwise, a charge of $35 will be made to the consumer for removal and testing of said meter and resetting the same.
A. 
Seasonal service. Consumers supplied with seasonal service shall be deemed to desire said service supplied in each year unless the consumer shall give notice in writing to the district of his desire not to receive such water service not later than May 15 in each year.
B. 
Furnishing other persons. Consumers shall not furnish other persons with water nor permit anyone to take water without the district's consent.
Any new private water main, permitted only by permission of the Town Board, shall be installed in a manner directed by the district, and all service pipes, connections and other appliances from such private water main, from the time of inception, shall become the property of the district and subject to all provisions hereof.
A. 
Reasonable care and diligence. The district shall use reasonable care and diligence to provide a constant supply of water, but may at any time shut off the water in the mains in case of accident or for the purpose of making connections, alterations or repairs or for any other legitimate purposes and may restrict the use of water to conserve a sufficient supply for fire protection or any other emergency whenever the public welfare may demand it.
B. 
Nonliability. The district shall not be liable for any loss or damage from any excess or deficiency in the pressure, volume or supply of water.
[Amended 10-11-2018 by L.L. No. 6-2018]
Any person desiring to be supplied with water from the system shall make application in writing to the operator upon blanks prescribed and furnished by the district and shall pay all charges applicable to the service applied for at the time of making said application. The Town Supervisor is hereby authorized and designated to receive and collect all charges and other fees payable to the Town pursuant to this chapter.
A. 
Generally. The specifications shall apply to all new construction, additions and improvements to existing water systems and water districts in the Town of Warwick as well as any new water districts to be formed in the future. All new construction, additions and improvements shall be designed and constructed in accordance with the policies of the Recommended Standards For Water Works, 1982 Edition, New York State Health Department Board No. 42. In addition, such installation shall be evaluated for compliance with the Town of Warwick Wellhead Protection Policy as it appears in Chapter 159 herein.
[Amended 12-30-2003 by L.L. No. 7-2003]
B. 
Water main design.
(1) 
Pressure. All water mains, including those not designed to provide fire protection, shall be sized after a hydraulic analysis based on flow demands and pressure requirements. The system shall be designed to maintain a minimum pressure of 20 pounds per square inch at ground level at all points in the distribution system under all conditions of flow. The normal working pressure in the distribution system should be approximately 60 pounds per square inch and not less than 35 pounds per square inch.
(2) 
Diameter. The minimum size of water main for providing fire protection and serving fire hydrants shall be six-inch diameter. Larger size mains will be required if necessary to allow the withdrawal of the required fire flow while maintaining the minimum residual pressure.
(3) 
Fire protection. When fire protection is to be provided, system design should be such that fire flows and facilities are in accordance with the requirements of the State Insurance Services Office.
(4) 
Hydrants. Water mains not designed to carry fire flows shall not have fire hydrants connected to them.
(5) 
Dead ends. Dead ends shall be minimized by looping of all mains whenever practical.
(6) 
Flushing. Where dead-end mains occur, they shall be provided with a fire hydrant if flow and pressure are sufficient or with an approved flushing hydrant or blowoff for flushing purposes. Flushing devices should be sized to provide flows which will give a velocity of at least 2.5 feet per second in the water main being flushed. No flushing device shall be directly connected to any sewer.
C. 
Valves. Sufficient valves shall be provided on water mains so that inconvenience and sanitary hazards will be minimized during repairs. Valves should be located at not more than five-hundred-foot intervals in commercial districts and at not more than one-block or eight-hundred-foot intervals in other districts.
D. 
Hydrants.
(1) 
Location and spacing. Hydrants should be provided at each street intersection and at intermediate points between intersections as recommended by the State Insurance Services Office. Generally, hydrant spacing may range from 350 to 600 feet, depending on the area being served.
(2) 
Valves and nozzles. Fire hydrants should have a bottom valve of at least five inches, one four-and-one-half-inch pumper nozzle and two two-and-one-half-inch nozzles.
(3) 
Hydrant leads. The hydrant lead shall be a minimum of six inches in diameter. Auxiliary valves shall be installed in all hydrant leads.
(4) 
Drainage. Hydrant drains should be plugged. When the drains are plugged, the barrels must be pumped dry. If drains are not plugged, a gravel pocket or dry well shall be provided unless the natural soils will provide adequate drainage. Hydrant drains shall not be connected to or located within 10 feet of sanitary sewers or storm drains.
E. 
Air relief valves; valve, meter and blowoff chambers.
(1) 
Air relief valves. At high points in water mains where air can accumulate, provisions shall be made to remove the air by means of hydrants or air relief valves. Automatic air relief valves shall not be used in situations where flooding of the manhole or chamber may occur.
(2) 
Air relief valve piping. The open end of an air relief pipe from automatic valves shall be extended to at least one foot above grade and provided with a screened, downward-facing elbow. The pipe from a manually operated valve should be extended to the top of the pit.
(3) 
Chamber drainage. Chambers, pits or manholes containing valves, blowoffs, meters or other such appurtenances to a distribution system shall not be connected directly to any storm drain or sanitary sewer, nor shall blowoffs or air relief valves be connected directly to any sewer. Such chambers or pits shall be drained to the surface of the ground where they are not subject to flooding by surface water or to absorption pits underground.
F. 
Installation of mains.
(1) 
Standards. Specifications shall incorporate the provisions of the AWWA standards and/or manufacturer's recommended installation procedures.
(2) 
Bedding. A continuous and uniform bedding shall be provided in the trench for all buried pipe. Backfill material shall be tamped in layers around the pipe and to a sufficient height above the pipe to adequately support and protect the pipe. Stones found in the trench shall be removed for a depth of at least six inches below the bottom of the pipe.
(3) 
Cover. All water mains shall be covered with sufficient earth or other insulation to prevent freezing.
(4) 
Blocking. All tees, bends, plugs and hydrants shall be provided with reaction blocking, tie rods or joints designed to prevent movement.
(5) 
Pressure and leakage testing. All types of installed pipe shall be pressure tested and leakage tested in accordance with the latest edition of AWWA Standard C600.
(6) 
Disinfection. All new, cleaned or repaired water mains shall be disinfected in accordance with the latest edition of AWWA Standard 0601. The tablet method shall not be permitted.
G. 
Separation of water mains, sanitary sewers and storm sewers.
(1) 
Parallel installation. Water mains shall be laid at least 10 feet horizontally from any existing or proposed sewer. The distance shall be measured edge to edge. In cases where it is not practical to maintain a ten-foot separation, the reviewing authority may allow deviation on a case-by-case basis if supported by data from the design engineer. Such deviation may allow installation of the water main closer to a sewer, provided that the water main is laid in a separate trench or on an undisturbed earth shelf located on one side of the sewer and at such an elevation that the bottom of the water main is at least 18 inches above the top of the sewer.
(2) 
Crossings. Water mains crossing sewers shall be laid to provide a minimum vertical distance of 18 inches between the outside of the water main and the outside of the sewer. This shall be the case where the water main is either above or below the sewer. At crossings, one full length of water pipe shall be located so that both joints will be as far from the sewer as possible. Special structural support for the water and sewer pipes may be required.
(3) 
Force mains. There shall be at least a ten-foot horizontal separation between water mains and sanitary sewer force mains. There shall be an eighteen-inch vertical separation at crossings.
(4) 
Sewer manholes. No water pipe shall pass through or come in contact with any part of a sewer manhole.
H. 
Cross-connections and interconnections.
(1) 
Cross-connections. There shall be no connection between the distribution system and any pipes, pumps, hydrants or tanks whereby unsafe water or other contaminating materials may be discharged or drawn into the system.
I. 
Water services and plumbing. Water services and plumbing shall conform to relevant local and/or State Plumbing Codes or to the National Plumbing Code.
J. 
Service meters. Each service connection should be individually metered.