A. 
All Class III dischargers shall file with the Patterson Township Municipal Authority wastewater information deemed necessary by the Manager for determination of compliance with this Part 2, the NPDES permit conditions of those treatment facilities utilized by the Patterson Township Municipal Authority and state and federal law. Such information shall be provided by completion of a questionnaire designed and supplied by the Manager and by supplements thereto as may be necessary. Information requested in the questionnaire and designated by the discharger as confidential is subject to the conditions of confidentiality as set out in Subsection C.
B. 
Where a person owns, operates or occupies properties designated as a Class III discharger at more than one location, separate information submittals shall be made for each location as may be required by the Manager.
C. 
The Manager shall implement measures to ensure the confidentiality of information provided by a Class III discharger pursuant to this Part 2. In no event shall the Manager delegate this responsibility or disclose any claimed confidential information to any person without prior notice, in writing, to the owner and without providing the owner with the opportunity to protect such confidential information, including the right to seek judicial relief.
A. 
When required by the Manager, the owner of any property serviced by a building sewer carrying Class III wastewater discharges shall provide suitable access and such necessary meters and other appurtenances in the building sewer to facilitate observation, sampling and measurement of the wastewater. Such access shall be in a readily and safely accessible location and shall be provided in accordance with plans approved by the Manager. The access shall be provided and maintained at the owner's expense so as to be safe and accessible at reasonable times.
B. 
The Manager shall consider such factors as the volume and strength of discharge, rate of discharge, quantities of toxic materials in the discharge, wastewater treatment facility removal capabilities and cost effectiveness in determining whether or not access and equipment for monitoring Class III wastewater discharges shall be required.
C. 
Where the Manager determines access and equipment for monitoring or measuring Class III wastewater discharges is not practicable, reliable or cost-effective, the Manager may specify alternate methods of determining the characteristics of the wastewater discharge which will, in the Manager's judgment, provide an equitable measurement of such characteristics.
A. 
Measurements, tests and analyses of the characteristics of wastewater to which reference is made in this Part 2 shall be determined in accordance with the latest edition of Standard Methods for the Examination of Water and Wastewater, published by the American Public Health Association, or such alternate methods approved by the Manager and which comply with state and federal law. Sampling methods, locations, times, durations and frequencies are to be determined on an individual basis, subject to approval by the Manager. The discharger shall have the option to use, at his own expense, more complete sampling methods, locations, times, durations and frequencies than specified by the Manager.
B. 
Measurements, tests and analyses of the characteristics of wastewater required by this Part 2 shall be performed by a qualified laboratory. When such analyses are required of a discharger, the discharger may, in lieu of using the Patterson Township Municipal Authority's laboratory, make arrangement with any qualified laboratory, including that of the discharger, to perform such analysis.
C. 
Monitoring of wastewater characteristics necessary for determination of compliance with applicable pretreatment standards shall be conducted on the basis of the following schedule, unless more frequent monitoring is required by authority other than this Part 2, or if the Manager, in his judgment, determines that the characteristics of the specific discharge warrant a different frequency monitoring:
Average Actual Daily User Discharge
(gallons per day)
Monitoring Frequency
Less than 100,000
Semiannually
100,000 to 999,999
Quarterly
More than 999,999
Monthly
D. 
Monitoring of wastewater characteristics for any purpose other than the determination of compliance with pretreatment standards shall be conducted on a frequency deemed necessary by the Manager.
E. 
Upon demonstration by any person that the characteristics of the wastewater discharged by that person are consistent, the Manager may reduce the frequency as may be required by authority other than this Part 2, except in no case shall the frequency of monitoring be less than semiannual for the determination of compliance with pretreatment standards.
F. 
In determining the discharge characteristic factors, such as continuous or batch operation and seasonal operation, the information requirements of other provisions of this Part 2 shall be considered by the Manager. The Manager may obtain wastewater samples as required to verify the consistency of discharge characteristics.
G. 
Fees for any given measurement, test or analysis of wastewater required by this Part 2 and performed by the Patterson Township Municipal Authority shall be the same for all classes of dischargers, regardless of the quantity or quality of the discharge, and shall reflect only direct cost. Costs of analyses performed by an independent laboratory at the option of the discharger shall be borne directly by the discharger.
If the drainage or discharge from any establishment causes a deposit, obstruction or damage to any of the Patterson Township Municipal Authority's wastewater facilities, the Manager shall cause the deposit or obstruction to be promptly removed or cause the damage to be promptly repaired. The cost for such work, including materials, labor and supervision, shall be borne by the person causing such deposit, obstruction or damage.