Habitable space shall meet the following light
and ventilation requirements:
A. All habitable space must be provided with natural
light through one or more windows, skylights, transparent or translucent
panels, or any combination thereof, that face directly on legal open
spaces at least six inches above the adjoining finished grade or area
above any roofline. The amount of light shall be equivalent to that
transmitted through clear glass equal in area to 10% of the floor
area of the habitable space.
B. Habitable space shall be provided with artificial
light.
C. Habitable space shall be provided with natural ventilation
through openable parts of windows or other openings in exterior walls
that face legal open spaces above the adjoining finished grade or
above a roof, or through openable parts of skylights, providing total
clear ventilation area equal to not less than 5% of the total floor
area of each habitable space.
D. Habitable space may also be provided with mechanical
ventilation, in addition to natural ventilation.