In preparing the detailed subdivision plans, the subdivider shall divide the project into three major "sets" of plans as follows: subdivision plat record plan; subdivision grading and drainage plan; subdivision utility and street plan. Specifically, the drawings shall include, but not be limited to, the following:
A. Subdivision plat record plan. Unless the County Clerk specifies otherwise, the plat shall be 17 inches by 22 inches or 34 inches by 44 inches in size and shall be drawn at a minimum scale of 50 feet to one inch unless otherwise approved. Where more than one sheet is required to show the entire development, a key map showing all sections shall be provided. The following information shall be clearly shown:
(1) Title of the sheet, including name and address of the subdivider, owner and developer. (Where developer or owner is a corporation, a statement of corporate ownership and officers shall be submitted to the Planning Board, at the preliminary stage.) A signature block shall be provided for all required approvals including the Planning Board Chairman, Town Engineer, Monroe County Health Department, Monroe County Water Authority, as appropriate, as well as any other approvals required by local, county or state law or as required by the Planning Board.
(2) North point, graphic scale and date.
(3) The boundaries of the subdivision and information to show the location of the subdivision in relation to surrounding property and streets, including names of owners of adjacent land or names of adjacent subdivision. In whatever manner that is practical, the subdivision boundary shall be referenced from two directions to establish USC & GS monuments or New York State Plane Coordinate monuments. In the event that such monuments have been obliterated, the subdivision boundary shall be referenced to the nearest highway intersections or at least two previously established monuments of subdivisions of public lands. Any combination of types of reference ties may be accepted which would fulfill the requirement of exact measurements from the subdivision boundary to reference points previously established.
(4) The lines of existing and proposed streets within the subdivision and the lines of existing or approved streets on adjoining properties.
(5) The names of existing and proposed streets.
(6) The lines and dimensions of proposed lots, which shall be numbered and shall have their area in square feet indicated.
(7) The lines and purposes of existing and proposed easements immediately adjoining and within the subdivision.
(8) The lines and dimensions of all property which is offered, or to be offered, for dedication for public use, with the purpose indicated thereon, and of all property that is proposed to be reserved by deed covenant for the common use of the property owners of the subdivision.
(9) The location of monuments to be placed within the subdivision.
(10) The locations of any municipal and zoning boundary lines within the subdivision.
(11) Statements as to:
(a) The zoning of the property within the subdivision.
(b) Compliance of the proposed lots with zoning requirements. If any lots do not comply but are covered by zoning variances, the statement should include reference to such variance.
(12) Certification by a licensed professional engineer and a licensed land surveyor as evidence of professional responsibility for the preparation of the plat and a place for the liber and page where filed.
B. Subdivision grading and drainage plan. This plan shall be on a separate sheet of the same size and scale as the plat and provide the following information:
(1) Contours of existing grade at intervals of not more than five feet. Intervals less than five feet may be required depending on the character of the topography. Contour to extend a minimum of 300 feet beyond property limits.
(2) Location of all buildings proposed.
(4) Final grades and/or contours at intervals of not more than two feet, less intervals may be required depending on topography.
(a) Location of all swales, creeks, ponds, drainage outfall, etc.
(b) All grades shall be established from USC & GS datum.
(5) Location and means of controlling erosion within the project limits.
(6) Slope stabilization details.
(8) Stormwater retention basins and ground recharge facilities.
(9) Certification by a licensed professional land surveyor of the finished grades after completion of grading.
C. Subdivision utility and street plan. This plan shall be on a separate sheet of the same size and scale as the plat and provide the following details:
(1) Complete plans and profiles of all proposed sanitary and storm sewers, including:
(a) Inverts, grades, original and finished ground profiles above these sewers and top of manhole grades.
(b) Elevations of stormwater inlets.
(c) Type, material and class of pipe.
(2) Location and details of all other facilities, including water mains, gas mains, telephone and electric.
(3) Location of all existing utilities in and adjacent to the site to be developed.
(4) A statement as to:
(a) The pressure and flow available in existing water mains.
(b) The proposed number of units and anticipated sanitary sewage flow.
(c) The available stormwater facilities downstream of this project.
(5) Details of erosion and slope stabilization measures where applicable.
(6) Any other details pertinent to site construction.
D. The initial plans shall be modified to reflect as-built conditions.