[Ord. No. 41,
§ 260.1, 5-27-1963]
Every habitable room shall have at least one window or skylight
facing directly to the outdoors. The minimum aggregate area available
for unobstructed light shall be not less than 10% of the floor area
of such rooms.
[Ord. No. 41,
§ 260.2, 5-27-1963]
Every stair, hall, cellar and basement located in a structure
used for human habitation shall have either adequate natural or artificial
light available at all times.
[Ord. No. 41,
§ 260.3, 5-27-1963]
Every laundry, furnace room and all similar nonhabitable work
space located in a structure used for human habitation shall have
either adequate natural or artificial lighting available at all times.
[Ord. No. 41,
§ 260.4, 5-27-1963]
Every public hall and common stairway located in a structure
used for human habitation and which is used primarily for ingress
and egress in connection with two or more dwelling units or rooming
units shall be supplied with a proper amount of natural light or lighting
facilities controllable by the occupants of the structure and be available
at all times.
[Ord. No. 41,
§ 260.5, 5-27-1963]
Every habitable room shall have electric outlets properly connected to a source of electric power as required in §
12-69.
[Ord. No. 41,
§ 260.6, 5-27-1963]
Every bathroom, shower room, toilet room or compartment located
in a structure used for human habitation shall have permanently installed
artificial lighting fixtures.
[Ord. No. 41,
§ 260.7, 5-27-1963]
Every habitable room shall be ventilated by either openable
areas equal to 45% of the required window area or by equivalent mechanical
ventilation.
[Ord. No. 41,
§ 260.8, 5-27-1963]
Every bathroom, shower room, toilet room or compartment located
in a structure made for human habitation shall be adequately ventilated.