[R.O. 1996 § 410.430; Code 1985, § 57.10(1); CC 1990 § 13-151]
An adequate and safe sewerage system shall be provided in all mobile home and travel trailer parks for conveying and disposing of all sewage. Such system shall be designed, constructed and maintained in accordance with State and local laws.
[R.O. 1996 § 410.440; Code 1985, § 57.10(2); CC 1990 § 13-152]
A. 
A sanitary station shall be provided consisting of at least a tapped four-inch sewer riser pipe, connected to the travel trailer parking area sewerage system, surrounded at the inlet end by a concrete apron sloped to the drain, and provided with a suitable hinged cover; and a water outlet with the necessary appurtenances, connected to the parking area water supply system to permit periodic wash down of the immediate adjacent areas.
B. 
Each travel trailer parking area shall be provided with a sanitary station in the ratio of one (1) for every one hundred (100) trailer spaces or fractional part thereof.
C. 
Sanitary stations shall be screened from other activities by visual barriers such as fences, walls or natural growth and shall be separated from any trailer space by a distance of at least fifty (50) feet.
[R.O. 1996 § 410.450; Code 1985, § 57.10(3); CC 1990 § 13-153]
All sewer lines in both mobile home and travel trailer parks shall be located in trenches of sufficient depth to be free of breakage from traffic or other movements and shall be separated from the water supply system at a safe distance. Sewers shall be at a grade which will ensure a velocity of two (2) feet per second when flowing full. All sewer lines shall be constructed of materials approved by the City Engineer, shall be adequately vented and shall have watertight joints.
[R.O. 1996 § 410.460; Code 1985, § 57.10(4); CC 1990 § 13-154]
A. 
Individual sewer connections shall be provided and the following requirements shall apply:
1. 
The sewer riser pipe shall have at least a four-inch diameter, shall be trapped below the ground surface and shall be so located on the trailer space that the sewer connection to the trailer drain outlet will approximate a vertical position.
2. 
The sewer connection (see definition) shall have a nominal inside diameter of at least three (3) inches, and the slope of any portion thereof shall be at least one-fourth (1/4) inch per foot. The sewer connection shall consist of one (1) pipe line only without any branch fittings. All joints shall be watertight.
3. 
All materials used for sewer connections shall be corrosive resistant, non-absorbent and durable. The inner surface shall be smooth.
4. 
Provision shall be made for plugging the sewer riser pipe when a trailer does not occupy the space. Surface drainage shall be diverted away from the riser.
[R.O. 1996 § 410.470; Code 1985, § 57.10(5); CC 1990 § 13-155]
No liquid wastes from sinks shall be charged onto or allowed to accumulate on the ground surface.