Table 902(2)
Enclosure Exceptions
| ||
---|---|---|
Building Use Group
|
Exception Conditionsa
| |
Business
|
When connecting not more than two floor levels and less than
3,500 square feet per floor;
When connecting not more than three floor levels and the building
is equipped with an automatic fire-suppression system
| |
Education
|
When connecting not more than two floor levels and the building
is equipped with an automatic fire-suppression system
| |
Factory-industrial storage
|
When connecting not more than two floor levels;
When connecting not more than three floor levels and the building
is equipped with an automatic fire-suppression system
| |
Mercantile
|
When connecting not more than two floor levels and less than
2,000 square feet per floor;
When connecting not more than two floor levels and the building
is equipped with an automatic fire-suppression system
| |
Residential-hotels
|
When connecting not more than two floor levels and the building
is equipped with an automatic fire-suppression system
| |
Residential-apartment
|
When connecting not more than two floor levels with not more
than four dwelling units per floor;
When connecting not more than three floor levels with not more
than four dwelling units per floor and the building is equipped with
an automatic fire-suppression system
| |
Residential one- and two-family dwellings
|
In every case
|
NOTES:
| ||
---|---|---|
Note a:
|
1 square foot = 0.093 m2
|