[Ord. No. 2005-73]
A. 
Only fixtures used for personal hygiene shall be installed in a rest room.
B. 
Commercial. Hand washing lavatory shall be installed in the same room as the water closet.
C. 
Mop sink, service sink and similar fixtures shall not be located next to or in the same room used for a gas fired furnace, boiler, or water heater.
[Ord. No. 2005-73]
A. 
It is required that grease interceptors (traps) be located outside the building and shall be accessible for maintenance purposes. See illustrations in the Illinois State Plumbing Code.
(1) 
Exception. When property restrictions prevent a grease interceptor to be located outside of an existing building, i.e., downtown buildings, strip and shopping malls, Plumbing Drainage Institute (PDI) approved grease interceptor may be allowed in lieu of the required outside grease interceptor. Such interceptor shall be installed with an approved solid interceptor located before the grease interceptor.
B. 
All restaurants which require a grease interceptor as per the Illinois State Plumbing Code shall install a minimum 1,000 gallon outside interceptor. Sandwich bars and carryout services which only prepare (not cooked foods) cold sandwiches shall install a minimum 250 gallon grease interceptor or as described in above code section.
C. 
Any business or individual which causes the City's sewer to become laden or plugged with fats, oils, grease, or other substance will be required to reimburse a minimum of $2,500 (first offense) or actual cost whichever is greater to the City of Bloomington for any cost related to cleaning of said sewer. Fines will double for every reoccurrence of this violation.
[Ord. No. 2013-03]
[Ord. No. 2005-73; 10-12-2020 by Ord. No. 2020-67]
All piping related to the proper operation of a swimming pool, spas, or the like are part of plumbing work and must comply with the State of Illinois State Plumbing Code and this chapter including necessary permits required.