Exciting enhancements are coming soon to eCode360! Learn more 🡪
Town of Westfield, NJ
Union County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
The exterior of a structure and all necessary structures shall be maintained in good repair, structurally sound and sanitary manner so as not to constitute a public nuisance or blighted condition, or otherwise pose a threat to the health, safety or welfare of the occupants of the premises or the public. The application and enforcement of each of the other sections of this Article VIII shall be in accordance with the foregoing standards.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All supporting structural members of all structures shall be kept structurally sound, free of deterioration and maintained capable of safely bearing the dead and live loads imposed upon them.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All foundation walls shall be maintained so as to carry the safe design and operating dead and live loads and shall be maintained free from open cracks and breaks, so as not to constitute a public nuisance, blighted condition or otherwise be detrimental to public safety and welfare.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All exterior walls shall be free of holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness inside the walls. All exterior walls shall be free of loose peeling paint that constitutes a blighted condition. All exterior surface materials, including wood, composition or metal siding, shall be maintained weatherproof and shall be properly surface-coated when required to prevent deterioration. All fences shall be maintained structurally sound and free of rot.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018; 11-1-2016 by G.O. No. 2072]
All roofs shall be structurally sound, tight and not have defects which might admit rain. Roof drainage shall be adequate to prevent rainwater from causing dampness or deterioration of, or entering, the structure. Roof water shall not be discharged in a manner that creates a nuisance to owners or occupants of adjacent premises or that creates a public nuisance. Discharge of roof drains shall be to the roadway storm sewer system or on the ground; provided, however, in connection with new construction projects, roof drain discharge shall be connected to the storm sewer, if feasible; otherwise, discharge shall be routed to the roadway. No roof drainage shall be connected to the sanitary sewer.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All canopies, marquees, signs, metal awnings, stairways, fire escapes, standpipes, exhaust ducts and similar overhang extensions shall be maintained in good repair and be properly anchored so as to be kept in a safe and sound condition.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All chimneys, cooling towers, smoke stacks and similar appurtenances shall be maintained structurally safe, sound and in good repair.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
(a) 
Every stair, porch, fire escape or balcony and all appurtenances attached thereto shall be so constructed as to be safe to use and capable of supporting the anticipated loads and shall be maintained in sound condition and good repair. Every stair, porch and fire escape shall be maintained free of hazardous conditions such as snow, ice, mud and rubbish.
(b) 
Every flight of stairs which is four or more risers high and which is appurtenant to a structure which contains more than one dwelling unit or is used for commercial purposes shall have a handrail on at least one side of the stair, and every open portion of a stair fire escape, porch, landing or balcony which is more than 30 inches above the grade below shall have guardrails. Handrails shall be not less than 30 inches nor more than 34 inches, measured vertically above the nosing of the treads. Guardrails shall be not less than 30 inches high above the floor of the porch, landing or balcony. Every handrail and guardrail shall be firmly fastened and capable of bearing normally imposed loads and shall be maintained in good condition.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All window sashes shall be glazed with glass which is free from holes and cracks so as to exclude wind, rain or snow from entering the structure.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
During the period from April 1 to December 1, every door and window or other outside opening used for ventilation purposes serving any building containing more than one dwelling unit, and any building used for commercial purposes containing food preparation areas, food service areas or any areas where products used in food for human consumption are processed, manufactured, packaged or stored, shall be supplied with approved tight-fitting screens of not less than 16 mesh per inch, and every swinging screen door shall have a self-closing device in good working condition.
[G.O. No. 1694, § I; amended 6-3-2014 by G.O. No. 2018]
All basement hatchways and windows shall be maintained as to prevent the entrance of vermin, rain and surface drainage water into the structures.