All uses in all districts shall conform in operation, location, and construction to the performance standards hereinafter specified.
(1995 Code, ch. 9, art. 19, intro; Ordinance 2024-03-00998 adopted 3/21/2024)
Octave Band | Maximum Permitted Sound Pressure Level |
|---|---|
Cycles per Second | Decibels |
20-75 | 97 |
75-150 | 76 |
150-300 | 70 |
300-600 | 65 |
600-1,200 | 63 |
1,200-2,400 | 58 |
2,400-4,800 | 55 |
4,800-10,000 | 53 |
Type of Operation or Character of Noise | Correction in Decibels |
|---|---|
Noise source operates less than 20% of any one-hour period | Plus 5* |
Noise source operates less than 5% of any one-hour period | Plus 10* |
Noise source operates less than 1% of any one-hour period | Plus 15* |
Noise of impulsive character (hammering, etc.) | Minus 5 |
Noise of periodic character (hum, screech, etc.) | Minus 5 |
Noise present at night | Minus 7 |
* | Apply one correction only |
Frequency Cycles per Second | Displacement (Inches) |
|---|---|
0 to 10 | .0010 |
10 to 20 | .0008 |
20 to 30 | .0005 |
30 to 40 | .0004 |
40 and over | .0003 |