Table 17.130.050-1 of Section 17.130.050 Specific to Zones
| |||||||||
---|---|---|---|---|---|---|---|---|---|
Table 17.130.050-1 Required Build-to-Line,
Height, and Frontage Area.
| |||||||||
Standard [1]
|
Form-Based Zones
| ||||||||
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| ||
DENSITY AND INTENSITY (MAX.)[4]
| |||||||||
Dwelling Units per Acre
(Du/ac) (min./max.)
|
0/8
|
0/24
|
0/30
|
18/30
|
24/42
|
24/42
|
36/60
|
40/100
20/50 in subzone
| |
Floor Area Ratio (FAR)
(min./max.) [2]
|
0/0.4
|
0.4/0.6
0.2/0.4 in subzone
|
0.2/1
|
0.6/2.0
|
0.4/2.0
|
0.4/1.0
|
0.6/1.5
|
1.0/2.0
0.2/0.4 in subzone
| |
BUILD-TO LINES
| |||||||||
A
|
Primary Build-to Line
(max./min.)
|
40 ft./NA
|
5 ft./15 ft.
|
0 ft./10 ft.
|
5 ft./20 ft.
|
5 ft./15 ft.
|
0 ft./15 ft.
|
0 ft./15 ft.
|
0 ft./10 ft.
|
B
|
Secondary Build-to Line
(max./min.)
|
30 ft./NA
|
5 ft./15 ft.
|
0 ft./10 ft.
|
5 ft./20 ft.
|
5 ft./15 ft.
|
0 ft./15 ft.
|
0 ft./15 ft.
|
0 ft./10 ft.
|
BUILDING PLACEMENT WITHIN PRIVATE
FRONTAGE AREAS
| |||||||||
C
— x 100
D
|
Minimum Built Percentage of Primary
Frontage Width
|
NA
|
65% of primary frontage width
|
80% of primary frontage width
|
70% of primary frontage width
|
75% of primary frontage width
|
80% of primary frontage width
|
85% of primary frontage width
|
90% of primary frontage width
|
E
— x 100
F
|
Minimum Built Percentage of Secondary
Frontage Width
|
NA
|
30% of secondary frontage width
|
30% of secondary frontage width
|
30% of secondary frontage width
|
30% of secondary frontage width
|
30% of secondary frontage width
|
30% of secondary frontage width
|
40% of secondary frontage width
|
HEIGHT
| |||||||||
G
|
Ground Floor Residential Use (min.)
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
G
|
Ground Floor Nonresidential Use (min.)
|
12 ft.
|
12 ft.
|
15 ft.
|
12 ft.
|
12 ft.
|
15 ft.
|
15 ft.
|
15 ft.
|
H
|
Upper Floor Nonresidential Height
(min.)
|
9 ft.
|
9 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
9 ft.
|
9 ft.
|
9 ft.
|
I
|
Residential Finish Floor Elevation
above Grade at Max. Build-to Line (min.)
|
0 in. 36 in. max.
|
30 in.
|
30 in.
|
30 in.
|
30 in.
|
30 in.
|
30 in.
|
30 in.
|
I
|
Nonresidential Finish Floor Elevation
above Grade at Max. Build-to Line (max.)
|
18 in.
|
18 in.
|
18 in.
|
12 in.
|
12 in.
|
12 in.
|
12 in.
|
12 in.
|
J
|
Total Stories (max.)[3]
|
3 stories
|
3 stories
|
4 stories
|
5 stories
|
4 stories
|
4 stories
|
5 stories
| |
If located within a community activity
node, fronting Foothill Blvd or Haven Ave., or as approved consistent
with chapter 17. 138 (Large Site Development)
|
5 stories
|
5 stories
|
7 stories
|
no maximum
| |||||
PARKING SETBACKS (MIN.)
| |||||||||
K
|
Surface Parking, Front, or Street
Side if located on a Transit Priority Street
|
25 ft. from building facade
|
30 ft.
|
50 ft.
|
40 ft.
|
40 ft.
|
40 ft.
|
40 ft.
|
50 ft.
|
L
|
Surface Parking, Street Side (if
not located on a Transit Priority Street)
|
25 ft. from building facade
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
10 ft.
|
Notes:
| |
---|---|
1.
|
The maximums allowed by zone may not be attainable due to limitations
from other standards (e.g., building and design standards) or unique
site characteristics, such as lot size, trees, waterways, and steep
slopes.
|
2.
|
FAR applies to nonresidential portion of the development only,
including nonresidential portions of mixed-use development.
|
3.
|
Maximum height in feet determined by building type, see section 17.130.060. For properties within the Ontario Airport Land Use Compatibility Plan (OALCP), the maximum height is established in the OALCP. The OALCP standard supersedes the maximum height allowed in this article.
|
4.
|
Density and FAR are calculated individually. When there are
multiple development sites on a single property, individual development
sites may deviate from minimum or maximum standards so long as the
total site average FAR and Du/AC are within established limits
|
TABLE 17.130.060-1 ALLOWED BUILDING TYPES BY ZONE
| |||||||||
---|---|---|---|---|---|---|---|---|---|
Building Type
|
Section
|
Form-Based Zones
| |||||||
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| ||
Fourplex
|
17.130.060(A)
|
A
|
A
| ||||||
Attached Flex
|
17.130.060(B)
|
A
|
A
|
A
| |||||
Main Street
|
17.130.060(C)
|
A
|
A
|
A
|
A
|
A
|
A
|
A
|
A
|
Rowhouse
|
17.130.060(D)
|
A
|
A
|
A
|
A
| ||||
Courtyard Building
|
17.130.060(E)
|
A
|
A
|
A
|
A
|
A
|
A
| ||
Multiplex
|
17.130.060(F)
|
A
|
A
|
A
|
A
|
A
|
A
| ||
Mid-Rise Building
|
17.130.060(G)
|
A
|
A
|
A
|
A
|
A
| |||
High-Rise Building
|
17.130.060(H)
|
A
| |||||||
Estate
|
17.130.060(I)
|
A
| |||||||
Extra Large House
|
17.130.060(J)
|
A
| |||||||
Large House
|
17.130.060(K)
|
A
|
Note:
| |||||||||
---|---|---|---|---|---|---|---|---|---|
A = Building Type Allowed
|
ZONES PERMITTED: NG3, CE1
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 60 ft, Max. 100 ft
| ||||||
B
|
Depth
|
Min. 90 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building (All Attached Units)
| ||||||||
Build-To Lines
|
See Table 17.130.050-1
| |||||||
C
|
Interior Side Yard Setback
|
Min. 10% of lot width
| ||||||
Rear Yard Setback
|
None
| |||||||
Accessory Structures
| ||||||||
D
|
Interior Side Setback
|
Min. 3 ft
| ||||||
Rear Setback
|
None
| |||||||
Building Separation
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
Primary Building (All Attached Units)
| ||||||||
To Eave/Top of Parapet
|
Max. 22 ft
| |||||||
Overall
|
Max. 30 ft
| |||||||
Accessory Structures
| ||||||||
Overall
|
Max. 1-story
| |||||||
BUILDING MASSING
| ||||||||
Primary Building (All Attached Units)
| ||||||||
E
|
Width
|
Max. 60 ft
| ||||||
F
|
Depth
|
Max. 50 ft
| ||||||
Detached Garage
| ||||||||
Area
|
Max. 800 sq ft total for detached garages
| |||||||
G
|
Maximum Dimension (in any direction)
|
40 ft
| ||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Individual Entrances
|
Must face the primary frontage area
| |||||||
Shared Entrances
|
Must face a private frontage area or a walkway leading directly
to a private frontage area
| |||||||
Rear Lane
|
Required where possible
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
50% of site
| |||||||
OPEN SPACE
| ||||||||
H
|
Common Usable Open Space, Area
|
Min. 300 sq ft
| ||||||
I
|
Common Usable Open Space, Minimum Dimension ( in any direction)
|
15 ft
|
ZONES PERMITTED: NG3, CE1, ME1
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 25 ft, 32 ft on corner lots; Max. 100 ft
| ||||||
B
|
Depth
|
Min. 75 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building (All Attached Units)
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
C
|
Interior Side Yard Setback
|
0 ft, Min. 5 ft at end of row of attached buildings
| ||||||
Rear Yard Setback
|
Min. 5 ft
| |||||||
Accessory Structures
| ||||||||
D
|
Interior Side Setback
|
None
| ||||||
Rear Setback
|
None
| |||||||
Building Separation
|
Min 8 ft
| |||||||
BUILDING HEIGHT
| ||||||||
Primary Building (All Attached Units)
| ||||||||
To eave/top of parapet
|
Max. 35 ft
| |||||||
Overall
|
Max. 42 ft
| |||||||
Accessory Structures
| ||||||||
Overall
|
Max. 1-story
| |||||||
BUILDING MASSING
| ||||||||
Primary Building (All Attached Units)
| ||||||||
E
|
Width
|
Max. 100 ft; max. 50 ft per attached unit
| ||||||
F
|
Depth
|
Max. 60 ft
| ||||||
Detached Garages
| ||||||||
G
|
Width
|
Max. Width of unit
| ||||||
H
|
Depth
|
Max. 24 ft
| ||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Nonresidential Entrances
|
Must face the private frontage area
| |||||||
Residential Entrances, Shared or Individual
|
Must face a private frontage area or a walkway leading directly
to a private frontage area
| |||||||
Rear Lane
|
Required where possible
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
75% of site
| |||||||
OPEN SPACE
| ||||||||
I
|
Common Usable Open Space, Area
|
Min. 100 sq ft per unit
| ||||||
J
|
Common Usable Open Space, Minimum Dimension (in any direction)
|
10 ft
|
ZONES PERMITTED: NG3, CE1, ME1, ME2, CO1, CO2, CE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 25 ft, Max. 180 ft
| ||||||
B
|
Depth
|
Min. 65 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
Interior Side Yard Setback
|
None
| |||||||
Rear Yard Setback
|
Min. 5 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 35 ft
| |||||||
Overall
|
Max. 40 ft
| |||||||
BUILDING MASSING
| ||||||||
C
|
Width
|
Max. 180 ft
| ||||||
D
|
Depth
|
Max. 100 ft
| ||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Entrances
|
Must face the private frontage area
| |||||||
Required Paseos
|
Main Street frontages exceeding 150 ft in width must be interrupted
by a paseo that connects the frontage area to the parking area.
|
ZONES PERMITTED: NG3, CE1, ME2, CO1
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 60 ft, Max. 250 ft
| ||||||
B
|
Depth
|
Min. 60 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building (All Attached Units)
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
C
|
Interior Side Yard Setback
|
Min. 5 ft at end of row of attached units
| ||||||
Rear Yard Setback
|
Min. 5 ft
| |||||||
Accessory Structures
| ||||||||
Interior Side Setback
|
None
| |||||||
Rear Setback
|
None
| |||||||
Building Separation
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
Primary Building (Row of Attached Units)
| ||||||||
To Eave/Top of Parapet
|
MAX. 32 FT
| |||||||
Overall
|
Max. 40 ft
| |||||||
Accessory Structure
| ||||||||
Overall
|
Max. 1-story
| |||||||
BUILDING MASSING
| ||||||||
Primary Building (Row of Attached Units)
| ||||||||
D
|
Width
|
Max. 240 ft
| ||||||
E
|
Depth
|
Max. 50 ft
| ||||||
Unit
| ||||||||
F
|
Width
|
Max. 30 ft
| ||||||
Detached Garages
| ||||||||
Width
|
Width of unit
| |||||||
Depth
|
Max. 24 feet
| |||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Individual Entrances
|
Must face the private frontage area
| |||||||
Rear Lane or Shared Driveway
|
Required where possible
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
75% of site
| |||||||
OPEN SPACE
| ||||||||
Private Open Space, Area
|
Min. 100 sq ft per unit
| |||||||
Private Usable Open Space, Minimum Dimension (in any direction)
|
8 ft
|
ZONES PERMITTED: CE1, ME1, CO1, CO2, CE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 80 ft, Max. 136 ft
| ||||||
B
|
Depth
|
Min. 60 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
C
|
Interior Side Yard Setback
|
Min. 8 ft
| ||||||
Rear Yard Setback
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 42 ft
| |||||||
Overall
|
Max. 52 ft
| |||||||
BUILDING MASSING
| ||||||||
D
|
Width
|
Max. 140 ft
| ||||||
E
|
Depth
|
Max. 120 ft
| ||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Entrances
|
Residential entrances must face courtyard or private frontage
area
| |||||||
OPEN SPACE/COURTYARD
| ||||||||
F
|
Width
|
Min. 25 ft, Max. 50 ft
| ||||||
G
|
Depth
|
Min. 25 ft, Max. 75 ft
| ||||||
A courtyard may satisfy the open space requirement if the courtyard is open and accessible to the public and is consistent with the applicable requirements in chapter 17.134 (Public Open Space).
|
ZONES PERMITTED: NG3, CE1, ME1, CO1, CO2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 60 ft, Max. 176 ft
| ||||||
B
|
Depth
|
Min. 60 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
C
|
Interior Side Yard Setback
|
Min. 8 ft
| ||||||
Rear Yard Setback
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 42 ft
| |||||||
Overall
|
Max. 52 ft
| |||||||
BUILDING MASSING
| ||||||||
Primary Building (All Attached Units)
| ||||||||
D
|
Width
|
Max. 160 ft
| ||||||
E
|
Depth
|
Max. 80 ft
| ||||||
BUILDING ENTRANCES AND ACCESS
| ||||||||
Entrances
|
Must face the private frontage area
| |||||||
Rear Lane
|
Required where possible
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
75% of site
| |||||||
COMMON OPEN SPACE
| ||||||||
F
|
Common Usable Open Space, Area
|
Min. 300 sq. ft
| ||||||
G
|
Common Usable Open Space, Minimum Dimension (in any direction)
|
15 ft
|
ZONES PERMITTED: ME1, ME2, CO1, CO2, CE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 150 ft, Max. 400 ft
| ||||||
B
|
Depth
|
Min. 150 ft, Max. 400 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
Interior Side Yard Setback
|
None
| |||||||
Rear Yard Setback
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 80 ft
| |||||||
Overall
|
Max. 92 ft
| |||||||
BUILDING MASSING
| ||||||||
C
|
Width
|
Max. 400 ft
| ||||||
D
|
Depth
|
Max. 390 ft
| ||||||
OPEN SPACE
| ||||||||
E
|
Common Usable Open Space, Area
|
Min. 30 sq. ft. per unit
| ||||||
F
|
Common Usable Open Space, Minimum Dimension (in any direction)
|
20 ft
|
ZONES PERMITTED: CE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 150 ft, Max. 400 ft
| ||||||
B
|
Depth
|
Min. 150 ft, Max. 400 ft
| ||||||
BUILDING SETBACKS
| ||||||||
Build-To Line
|
See Table 17.130.050-1
| |||||||
Interior Side Yard Setback
|
None
| |||||||
Rear Yard Setback
|
Min. 10 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 120 ft
| |||||||
Overall
|
Max. 132 ft
| |||||||
BUILDING MASSING
| ||||||||
C
|
Width
|
Max. 400 ft
| ||||||
D
|
Depth
|
Max. 390 ft
| ||||||
OPEN SPACE
| ||||||||
E
|
Common Usable Open Space, Area
|
Min. 30 sq. ft. per unit
| ||||||
F
|
Common Usable Open Space, Minimum Dimension (in any direction)
|
20 ft
|
ZONES PERMITTED: NE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 100 ft (corner lots add 15 ft to min.)
| ||||||
B
|
Depth
|
Min. 120 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building
| ||||||||
C
|
Build-To Line
|
See Table 17.130.050-1
| ||||||
D
|
Interior Side Yard Setback
|
Min. 15% of lot width
| ||||||
E
|
Rear Yard Setback
|
Min. 30 ft
| ||||||
Secondary Building
| ||||||||
Primary/Secondary
|
Behind Primary building
| |||||||
F
|
Interior Side Yard Setback
|
Min. 10 ft
| ||||||
G
|
Rear Yard Setback
|
Min. 5 ft w/rear lane
Min. 10 ft w/o rear lane
| ||||||
Distance Between Buildings
|
Min. 20 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 24 ft
| |||||||
Overall
|
Max. 36 ft
| |||||||
BUILDING MASSING
| ||||||||
Primary Mass
| ||||||||
Width
|
Max. 40 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Wing(s)
| ||||||||
Width
|
Max. 20 ft
| |||||||
Depth (front wing)
|
Max. 20 ft
| |||||||
Secondary Building(s)
| ||||||||
Width
|
Max. 30 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Depth
|
Max. 36 ft
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
25% of site
| |||||||
OPEN SPACE
| ||||||||
Private Usable Open Space, Area
|
Min. 25% of the site
| |||||||
Private Usable Open Space, Minimum Dimension (in any direction)
|
30 ft
|
ZONES PERMITTED: NE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 80 ft, Max. 100 ft
| ||||||
B
|
Depth
|
Min. 120 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building
| ||||||||
C
|
Build-To Line
|
See Table 17.130.050-1
| ||||||
D
|
Interior Side Yard Setback
|
Min. 15% of lot width
| ||||||
E
|
Rear Yard Setback
|
Min. 30 ft
| ||||||
Secondary Building
| ||||||||
Primary/Secondary
|
Behind Primary building
| |||||||
F
|
Interior Side Yard Setback
|
Min. 10 ft
| ||||||
G
|
Rear Yard Setback
|
Min. 5 ft w/rear lane
Min. 10 ft w/o rear lane
| ||||||
Distance Between Buildings
|
Min. 20 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 24 ft
| |||||||
Overall
|
Max. 36 ft
| |||||||
BUILDING MASSING
| ||||||||
Primary Mass
| ||||||||
Width
|
Max. 40 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Wing(s)
| ||||||||
Width
|
Max. 20 ft
| |||||||
Depth (front wing)
|
Max. 20 ft
| |||||||
Secondary Building(s)
| ||||||||
Width
|
Max. 30 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Depth
|
Max. 36 ft
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
30% of site
| |||||||
OPEN SPACE
| ||||||||
Private Usable Open Space, Area
|
Min. 25% of the site
| |||||||
Private Usable Open Space, Minimum Dimension (in any direction)
|
30 ft
|
ZONES PERMITTED: NE2
| ||||||||
---|---|---|---|---|---|---|---|---|
NE2
|
NG3
|
CE1
|
ME1
|
ME2
|
CO1
|
CO2
|
CE2
| |
DEVELOPMENT SITE SIZE
| ||||||||
A
|
Width
|
Min. 60 ft, Max. 80 ft
| ||||||
B
|
Depth
|
Min. 110 ft
| ||||||
BUILDING PLACEMENT
| ||||||||
Primary Building
| ||||||||
C
|
Build-To Line
|
See Table 17.130.050-1
| ||||||
D
|
Interior Side Yard Setback
|
Min. 15% of lot width or 10 ft.
| ||||||
E
|
Rear Yard Setback
|
Min. 30 ft
| ||||||
Secondary Building
| ||||||||
Primary/Secondary
|
Behind Primary building
| |||||||
F
|
Interior Side Yard Setback
|
Min. 5 ft
| ||||||
G
|
Rear Yard Setback
|
Min. 5 ft w/rear lane
Min. 10 ft w/o rear lane
| ||||||
Distance Between Buildings
|
Min. 20 ft
| |||||||
BUILDING HEIGHT
| ||||||||
To Eave/Top of Parapet
|
Max. 24 ft
| |||||||
Overall
|
Max. 36 ft
| |||||||
BUILDING MASSING
| ||||||||
Primary Mass
| ||||||||
Width
|
Max. 40 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Wing(s)
| ||||||||
Width
|
Max. 20 ft
| |||||||
Depth (front wing)
|
Max. 15 ft
| |||||||
Secondary Building(s)
| ||||||||
Width
|
Max. 30 ft
| |||||||
Depth
|
Max. 30 ft
| |||||||
Height
|
Max. 36 ft
| |||||||
LOT COVERAGE
| ||||||||
Maximum
|
35% of site
| |||||||
OPEN SPACE
| ||||||||
Private Usable Open Space, Area
|
Min. 25% of the site
| |||||||
Private Usable Open Space, Minimum Dimension (in any direction)
|
25 ft
|