The
California Building Code Volumes 1 and 2, 2022 Edition,
and Appendices G, H, I published by the International Code Council,
and as modified by the amendments, additions and deletions set forth
hereinafter, is hereby adopted by reference as the California Building
Code of the city of South San Francisco and may be cited as such.
(Ord. 1648 § 3B, 2022)
Set forth below are the amendments, additions and deletions
to the 2022
California Building Code, Volumes 1 and 2. Chapter, section
and table numbers used herein are those of the California Building
Code.
(Ord. 1648 § 3B, 2022)
1907.1.2 Slab on Grade is added to read
as follows:
New concrete slabs supported directly on the ground within the
foundation perimeter and used as a finished floor, or as a base for
other floor finishes shall meet the following requirements:
1. Steel
reinforcement equivalent to no. 3 deformed steel bars at 18 inches
on center each way placed approximately mid-depth within the concrete
slab. Blocks or chairs shall be provided in order to maintain the
reinforcement in the center of the slab.
(Ord. 1648 § 3B, 2022)
1.8.10.3 Moved Buildings is added to
read as follows:
Buildings or structures moved into or within the jurisdiction
shall comply with the provisions of this code for new buildings or
structures. In addition to all other requirements of the building
code relative to the moving of buildings and structures, no permit
for the moving of a building or structure shall be granted until the
applicant has filed with the Chief Building Official the following
items:
1. A performance
bond in favor of the city, of not less than $1,000 nor more than $100,000,
as the Chief Building Official may determine, shall be conditioned
to require the applicant to strictly comply with all conditions and
provisions of this chapter, and of any provision of the municipal
code relating to the moving of buildings or structures, and of any
order, rule or regulation which may be hereafter passed or adopted
by the City Council. The applicant also shall be required to pay any
and all damages to any fence, hedge, tree, pavement, sidewalk, street,
curb, gas, sewer or water pipe, electric wire or pole supporting the
same, or to any public or private property which may result from moving
the building or structure; and
2. An
undertaking to indemnify, defend and hold harmless the city and its
elective officers, agents and employees against all liabilities, claims,
actions, judgments, cost or any expense which may for any reason arise
out of the issuance of said permit or moving of such buildings or
structures.
All removals made under any permit granted for such moving shall
be done over and along only the street or streets designated in such
permit, and at the times therein specified, and shall be done in a
careful manner to the satisfaction of the Chief Building Official,
and the Public Works Director/City Engineer.
|
No person owning or having charge of the removal of any building
or structure being moved over any street, shall permit such building
or structure to be, or stand, on any street within the limits of any
one block for a period of more than 24 hours.
|
No person owning or having charge of the removal of any building
or structure being moved over any street, shall allow or cause injury
to any fence, hedge, tree, pavement, street, sidewalk, curb, gas pipe,
water pipe, sewer pipe, electric wire or pole supporting same, or
any other public or private property by reason of such removal.
|
Temporary structures such as reviewing stands and other miscellaneous
structures, sheds, construction trailers, canopies or fences used
for the protection of the public and/or in conjunction with construction
work may be erected by special permit from the Chief Building Official
for a limited period of time. Such buildings or structures need not
comply with the type of construction or fire-resistive time periods
required by this code. Temporary buildings or structures shall be
completely removed upon the expiration of the time limit stated in
the permit.
|
(Ord. 1648 § 3B, 2022)
R908.7 Spark Arresters Required is added
to read as follows:
Chimneys attached to any appliance or fireplace that burns solid
fuel shall be equipped with an approved spark arrester. The net free
area of the spark arrester shall not be less than four times the net
free area of the outlet of the chimney. The spark arrester screen
shall be heat and corrosion resistant equivalent to 12-gage wire,
19-gage galvanized or 24-gage stainless steel. Openings shall not
permit the passage of spheres having a diameter larger than ½
inch and shall not block the passage of spheres having a diameter
of less than 3/8 inch.
(Ord. 1648 § 3B, 2022)