This chapter shall be known as the city of Burlingame "Indoor Water Conservation Ordinance."
(Ord. 1846 § 2, (2010))
Indoor Water Use Efficiency Table | ||
|---|---|---|
Fixture | Residential | Nonresidential |
Toilets | ≤ 1.28 gpf, and ≥ 350 grams | ≤ 1.28 gpf, and ≥ 350 grams |
Urinals | ≤ 0.5 gpf | ≤ 0.5 gpf |
Showers | ≤ 2.0 gpm | ≤ 2.0 gpm |
Bathroom faucets | ≤ 1.5 gpm | ≤ 0.5 gpm |
Kitchen faucets | ≤ 2.2 gpm | ≤ 2.2 gpm |
Clothes washers | ≤ 6.0 water factor | ≤ 6.0 water factor |
Dishwashers | ≤ 6.5 gal/cycle, or energy star qualified | energy star qualified |
Cooling towers | ≥ 5 - 10 cycles, or ≥ 2.5 LSI | ≥ 5 - 10 cycles, or ≥ 2.5 LSI |
Food steamers | -- | Boiler less, or self-contained |
Ice machines | -- | ≤ 25 gal/100 lbs ice, or air-cooled |
Pre-rinse spray valves | -- | ≤ 1.15 gpm |
Automatic vehicle wash facilities | -- | ≥ 50% of water that is recycled on site |
Commercial refrigeration | -- | Closed loop, or air-cooled |
Meters | Submeters for RMF, and separate meter for outdoor if landscape >5000 sq. ft. | Submeters, and separate meter for outdoor if landscape >5000 sq. ft. |