No person shall install, or permit to be installed, an interconnection
between a drinking water supply and any equipment or connection of
any kind, class, or description which may contain water or any liquid
or substance unfit for human or domestic consumption. The director
shall make, or cause to be made, inspections to determine if such
conditions exist, and, if such interconnections are discovered, the
director shall require the purveyor of water to discontinue water
service unless the condition is abated within a reasonable period
of time fixed by the director. No device shall be sold in the city
which provides such an interconnection as a means of operation, unless
the water supply is adequately protected.
(Prior code § 68.360)
No opening shall be provided in any drainage system or in any
septic tank, settling tank, seepage pit, cesspool or other subsurface
disposal unit or system for the purpose of receiving the surface drainage
from any yard or building.
(Prior code § 68.361)
No person shall cover, or cause to be covered, any septic tank,
settling tank, seepage pit, cesspool, subsurface tile line system,
or other subsurface disposal system or unit prior to its approval
by the director as provided in this chapter.
(Prior code § 68.362)
It is unlawful for any person to connect any house sewer line
or other plumbing to a septic tank, settling tank, cesspool, seepage
pit or other subsurface sewage disposal unit or system hereafter installed,
constructed or reconstructed, unless such septic tank, settling tank,
cesspool, seepage pit or other subsurface sewage disposal unit or
system has been approved by the director, as provided in this chapter.
(Prior code § 68.363)
No privy vault, privy, cesspool, or water closet shall be allowed
by the owner or other person in charge of the premises, upon which
the same may be situated, to become foul or offensive; and when, in
the opinion of the director, any such privy, vault, or closet or cesspool
needs cleaning or disinfecting, it shall be the duty of the director
to notify such owner or other person having control to abate the same
by such disinfecting or cleaning as in the judgment of the director
may be necessary, or, in the case of a defective or offensive cesspool,
the owner, if deemed necessary by the director, shall connect the
premises to an available public sewer or construct a new sewage disposal
system that meets the requirements of this chapter.
(Prior code § 68.364)