Utility and Miscellaneous Group U, as defined in the building code, includes buildings and structures that are accessory in character and miscellaneous structures not classified in any specific occupancy in the building code, including, but not limited to, agricultural buildings, aircraft hangars (accessory to a one- or two-family residence), barns, carports, fences more than six feet high, grain silos (accessory to a residential occupancy), greenhouses, livestock shelters, private garages, retaining walls, sheds, stables, and towers.
(A) Utility and Miscellaneous Group U structures, when proposed to be located within any flood hazard area, including substantial improvement of such accessory structures, shall:
(1) Be located outside of the flood hazard area when a buildable portion of the property exists outside of the flood hazard area.
(2) Be anchored to prevent flotation, collapse or lateral movement resulting from hydrostatic loads, including the effects of buoyancy, during conditions of the base flood.
(3) Have electric service and/or mechanical equipment two feet above the base flood elevation, except that minimum electric service required to address life safety and electric code requirements for parking of vehicles and storage is allowed below the base flood elevation if designed to prevent water from entering or accumulating.
(4) Use flood damage-resistant materials below the base flood elevation.
(5) If built in flood hazard areas other than coastal high hazard areas, have flood openings in compliance with the residential code to allow for the automatic entry and exit of floodwaters.
(6) If built in coastal high hazard areas, be less than 100 square feet in area and constructed with breakaway walls.
(Ord. 5350 § 1, 2020)