Automobile courts and motels | 1 per sleeping unit or DU |
Banks | 1 per 200 sq. ft. gfa |
Business offices, such as public utility, commercial, insurance agencies, real estate sales | 1 per 300 sq. ft. gfa |
Bowling alleys | 4 per alley |
Churches | 1 per 6 fixed seats of assembly area, or 1 per 150 sq. ft. of assembly area if no fixed seats |
Dwellings, single-family or two-family (attached or detached) | |
Dwellings, multiple (more than two families) | 2 per DU, shall be enclosed 0.20 guest spaces per DU – permitted as open parking spaces; Section 11.33.090 |
Establishment for the sale and consumption on the premises of food and beverages: |
– having less than 4,000 sq. ft. of floor area | 1 per 100 sq. ft. gfa |
– having 4,000 sq. ft. of floor area or more | 40, plus 1 per 50 sq. ft. over 4,000 sq. ft. |
Furniture and appliances, hardware, household equipment, service shops, clothing or shoe repair, or personal services such as barber and beauty shops | 1 per 300 sq. ft. gfa |
Hospitals | 2 per bed |
Hotels | 1 per bedroom |
Industrial uses, except as otherwise specified herein | 1 per 3 employees on max. shift; or 1 per 450 sq. ft. gfa, whichever is greater |
Institutional | 1 per 400 sq. ft. gfa, plus 1 per 2 employees |
Laboratories, biochemical, X-ray, dental, and research and testing | 1 per 300 sq. ft. gfa |
Libraries | 1 per 250 sq. ft. gfa |
Manufacturing uses, such as creameries, bottling establishments, bakeries, canneries, and printing and engraving shops | 1 per 3 employees on max. shift; or 1 per 300 sq. ft. gfa, whichever is greater |
Mini-warehouse buildings | 1 per 25 storage cubicles (1) |
Mortuaries | 1 per 25 sq. ft. assembly room floor area |
Motor vehicle sales, machinery sales, or wholesale stores | 1 per 400 sq. ft. gfa |
Museums | 1 per 500 sq. ft. gfa |
Pharmacies, drugstores | 1 per 150 sq. ft. gfa |
Professional offices: |
– attorneys, accountants, engineers, architects | 1 per 200 sq. ft. gfa |
– medical, dental, optometrist, chiropractors, oculists, opticians | 1 per 150 sq. ft. gfa |
Public utilities facilities not having business offices on the premises | 1 per vehicle operated or kept on site; minimum 2 spaces |
Retail stores, except as otherwise specified herein: |
– having not more than 5,000 sq. ft. of floor area | 1 per 200 sq. ft. gfa |
– having more than 5,000 sq. ft. of floor area | 25, plus 1 per 150 sq. ft. over 5,000 sq. ft. |
Rooming houses, lodging houses, clubs, fraternity houses having sleeping rooms | 1 per sleeping room |
Rest homes and homes for older adults | 1 per 4 beds |
Sanitariums, children's homes, asylums, nursing homes | 1 per bed |
Schools | 1 per employee |
Stadiums, sports arenas, auditoriums (including school auditoriums), and other places of public assembly, and clubs and lodges having no sleeping quarters | 1 per 3 fixed seats for all assembly areas; or 1 per 100 sq. ft. floor area used for assembly |
Theaters | 1 per 3 seats up to 800 seats, plus 1 per 5 seats over 800 seats |
Trade and/or vocational schools | 3, plus 1 per student capacity; or 1 sq. ft. per 1 sq. ft. building gfa, whichever is greater |
Transportation and trucking terminal facilities | Adequate number as determined by the planning commission |
Uses specific to children, older adults, community assembly or people with disabilities | 1 per every 8 persons, plus 2 loading and unloading spaces |
Warehouses and storage buildings | 1 per 1,000 sq. ft. gfa, plus 1 per 200 sq. ft. office or sales area |