Where a building or structure is being served by an existing private sewer system, the property owner or his agent shall select one of the following options:
A.
Connect to the existing building sewer line at a point five feet from the building line of the building or structure.
B.
Connect to the existing building sewer line at any point between five feet from the building line and the private sewage disposal system; provided, the existing building sewer is exposed to determine its conformance to the State Plumbing Code; and provided, the portion of existing building sewer which is retained is tested for leakage in conformance with this chapter. All deficiencies of the existing building sewer shall be corrected and made to conform to the State Plumbing Code and to this chapter.
C.
Extend the building sewer to a point five feet from the building line and install new building sewer plumbing into from the building, thereby not using the existing building sewer line.
(Ord. 88-O-430 Art. IX § 1)