In every commercial or multifamily building and structure
there shall be provided a permanent means of access to the attic or roof.
B.Â
All attics and roofs of commercial and multifamily buildings
and structures shall be accessible by means of a stairway or scuttle. If the
scuttle opening in the attic floor is provided in lieu of a stairway, the
same shall be located in a public hallway situated below the attic floor and
shall be provided with an approved fixed ladder or balanced stairway to such
opening, securely anchored in place.
C.Â
Roof and ceiling scuttles of commercial and multifamily
buildings and structures shall be at least two feet by three feet, and roof
scuttles shall be located immediately above the attic stairway or ceiling
scuttle or in a location approved by the Fire Department or the Building Inspector.
The roof scuttle cover shall be covered with noncombustible material and shall
be held in place by means approved by the Fire Department or the Building
Inspector.