Where there is electrical service available to a structure, every habitable room of a dwelling unit and every guest room shall contain at least two separate and remote outlets, one of which may be a ceiling- or wall-type electric light fixture. In a kitchen, three separate and remote wall-type electric convenience outlets or two such convenience outlets and one ceiling- or wall-type electric light fixtures shall be provided. Every public hall, water closet compartment, bathroom, laundry or furnace room shall contain at least one electric light fixture. In addition to the electric light fixture in every bathroom and laundry room, there shall be provided at least one electric outlet.
All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner in accordance with all applicable laws. All electrical equipment shall be of an approved type.
Where it is found, in the opinion of the Building Inspector, that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the Building Inspector shall require the defects to be corrected to eliminate the hazard.