No unauthorized person shall uncover, make any
connection with or opening into, use, alter or disturb any public
sewer or appurtenance thereof without first obtaining a written permit
from the Superintendent.
No person shall discharge or cause to be discharged
any stormwater, surface water, groundwater, roof runoff, subsurface
drainage, cooling water or unpolluted industrial waters to any sanitary
sewer. Swimming pool drains shall not be connected to any sanitary
sewer.
Existing building laterals may be used in connection
with new buildings only when they are found, on examination by the
Superintendent, to meet all requirements of this chapter.
Whenever possible, the building lateral shall
be brought to the building at an elevation below the basement floor.
Building laterals laid parallel to a bearing wall shall not be installed
closer than three feet to such wall. The building lateral shall be
laid at uniform grade and in straight alignment insofar as possible.
Changes in direction shall be made only with properly curved pipe
and fittings. Changes of direction of 90° or greater shall be
made with a cleanout which extends to grade, terminating in a terminal
box set in concrete. Said cleanouts shall be provided in building
laterals every 75 feet minimum. The ends of all building or street
laterals which are not connected to the interior plumbing of the building
for any reason shall be sealed against infiltration by a suitable
stopper or plug or by other approved means.
In all buildings in which any building drain
is too low to permit gravity flow to the public sewer, wastewater
carried by such drain shall be lifted by mechanical means and discharged
to the building lateral, on approval of the Superintendent.
All excavations required for the installation
of a building or street lateral shall be open trench work unless otherwise
approved by the Superintendent. Pipe laying and backfilling, regardless
of pipe material used, shall be performed in general accordance with
Paragraphs 3 through 6 of ASTM Specification C-12, except that trench
width, measured at the top of the installed pipe, shall not exceed
the outside pipe diameter, plus 14 inches, and except that no backfill
shall be placed until the work has been inspected. The depth of cover
over the pipe shall be sufficient to afford protection from frost,
but in no case shall such depth be less than four feet.
The street lateral, building lateral or the
combined lateral shall be tested for infiltration/exfiltration by:
A. Any full pipe method described in §
125-27; or
B. A suitable joint method, with the prior written approval
of the Superintendent.
All excavations for constructing building laterals
shall be adequately protected with barricades and lights so as to
protect the public from hazard. Streets, sidewalks, parkways and other
public property disturbed in the course of the work shall be restored
in a manner satisfactory to the Superintendent.
All costs associated with the provisions of
this Article shall be borne by the property owner unless specifically
stated or agreed to be a cost borne by the Village. The property owner
shall indemnify the Village from any loss or damage that may be directly
or indirectly occasioned by the installation of the building and street
laterals and connections and appurtenances.