Exciting enhancements are coming soon to eCode360! Learn more 🡪
City of Nashua, NH
Hillsborough County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
This article shall be known as and may be cited as the "Plumbing Code of the City of Nashua, New Hampshire."
[Amended 3-9-2021 by Ord. No. O-21-045]
A certain document and referenced code on file in the Department of Building Safety of the City of Nashua, New Hampshire, being marked and designated as the "International Plumbing Code," adopted as per the New Hampshire State Building Code per RSA 155-A and as published by the International Code Council, Inc., and any amendments adopted thereto, is hereby adopted as the Plumbing Code of the City of Nashua, in the State of New Hampshire, for the control of buildings and building systems; and the regulations, provisions, penalties, conditions and terms of said code are hereby referred to, adopted and made part hereof as if fully set out in this chapter, with any amendments prescribed in this article.
A. 
Amend Section 101.1 by inserting: the City of Nashua.
B. 
Amend Section 106.6.2 by changing it to read:
106.6.2. Fee schedule. The fees for plumbing work shall be as provided for by this chapter.
C. 
Delete Section 106.6.3.
D. 
Amend Sections 108.4 and 108.5 by adding the following statement:
[Amended 3-9-2021 by Ord. No. O-21-045]
In place of the insertions in the model code text, it shall be clearly understood that all violations of the adopted codes of the City of Nashua shall be subject to the provisions of NRO Chapter 74 and RSA 676:15-17-b, without limitation of any remedy available to the City of Nashua at law or equity.
E. 
Amend Section 305.4.1 by inserting in the places provided, in the order of appearance, the following:
[Amended 3-9-2021 by Ord. No. O-21-045]
36 inches (914.4 mm)
Pertains to building sewers serving septic systems
48 inches (1,219.2 mm)
Pertains to other building sewers
F. 
Also amend Section 305.4.1 at the end of the section by adding the following:
[Amended 3-9-2021 by Ord. No. O-21-045]
Where insulated, the Code Official may accept lesser depths of building sewer placement.
G. 
Delete Section 501.6 and replace with the following:
501.6. Water temperature control in piping from tankless water heaters. The temperature of water from tankless water heaters intended for domestic or personal hygiene use shall be a maximum of 130° F. (55° C.). A tempering device conforming to ASSE 1017 shall be installed to control the water temperature. This provision shall not supersede the requirements for protective shower valves in accordance with Section 424.4.
H. 
Amend Section 501.8 by adding the following sentence to the end of the section:
Water temperatures supplying faucets for domestic or personal hygiene use shall be limited to a maximum of 130° F. (55° C.).
I. 
Amend Section 501 by inserting the following new subsection:
[Amended 3-9-2021 by Ord. No. O-21-045]
501.9. Minimum water heater temperatures.Water heaters and indirect-fired hot-water storage tanks shall be maintained at a minimum temperature of 140° F. (60° C.) and shall be equipped with a temperature-controlling device conforming to ASSE 1017 to provide for maximum hot-water temperatures to faucets in accordance with Section 501.8.
J. 
Amend Section 904.1 by inserting in the place provided: 18 inches; 305 mm.[1]
[Amended 3-9-2021 by Ord. No. O-21-045]
[1]
Editor's Note: Former Subsection K, regarding an amendment to Section 1003.3.1, which immediately followed this subsection, was repealed 3-9-2021 by Ord. No. O-21-045.