[Amended 7-15-1985 by L.L. No. 22-1985]
No unauthorized person shall uncover, make any connections with or opening into, use, alter or disturb any public sewer or appurtenance thereof, without first obtaining a written permit from the Village.
[Amended 11-18-1974 by L.L. No. 3-1974; 4-20-1981 by L.L. No. 2-1981; 5-20-1985 by L.L. No. 14-1985; 7-15-1985 by L.L. No. 22-1985]
There will be two classes of building sewer permits: Class A for residential services and Class B for commercial and industrial services. In either case, the owner or his agent shall make application on a special form furnished by the Village. The permit application shall be supplemented by any plans, specifications and other information considered pertinent in the judgment of the Superintendent. The permit fee for the same shall be as provided for in Chapter 137, Article II, of the Code.
All costs and expenses incident to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the Village from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer.
[Amended 7-15-1985 by L.L. No. 22-1985; 4-7-2003 by L.L. No. 1-2003]
A separate and independent building sewer shall be provided for every building, except that:
A. 
Where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer, provided that the Village will not assume any responsibility for damage caused by or resulting from any such single connection; and
B. 
Where the amount of street frontage attributable to up to four adjoining building lots makes the installation of a separate and independent building sewer to each of said lots more difficult and/or costly than the installation of a common building sewer the Superintendent may approve of the construction of a single common eight-inch private building sewer to be accessed by up to four independent lateral sewers provided that:
(1) 
The plans and specifications for the construction of said eight-inch common private building sewer are approved of by the Superintendent;
(2) 
The owner of each building which connects a lateral sewer to the eight-inch common private building sewer in question pays the same tap in and related fees to the Village which would be paid if said building were serviced by a separate and independent building sewer;
(3) 
Each property owner whose improvements are to be serviced by or through any such eight-inch common private building sewer executes an agreement acceptable to the Village in which said owner and any subsequent owner of the properties served by said eight-inch common private building sewer covenants and agrees to indemnify and hold the Village harmless for any and all claims, damages and expenses attributable to the construction, operation and use of said eight-inch common private building sewer;
(4) 
Each eight-inch common private building sewer approved hereunder shall be designed by a licensed professional engineer; and
(5) 
Further, each eight-inch common private building sewer submitted for approval hereunder shall be tested and certified as having no leakage, or if shown to have leakage, certified that such leakage is below the allowable level, prior to the requisite approval by the Department of Public Works Supervisor. Where building sewers are to serve multiple-dwelling structures, there shall be provided at least one separate building sewer for each group of four living units.
[Amended 7-15-1985 by L.L. No. 22-1985]
Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the Superintendent, to meet all requirements of this chapter.
[Amended 7-15-1985 by L.L. No. 22-1985; 12-1-1986 by L.L. No. 27-1986]
The size, slope, alignment, materials of construction of a building sewer and the methods used in excavating, placing of pipe, jointing, testing and backfilling of the trench shall all conform to the requirements of the New York State Uniform Fire Prevention and Building Code. The maximum infiltration rate for all new sanitary sewers shall not exceed 200 gallons per day per inch diameter per mile of pipe.
[Amended 1-22-1990 by L.L. No. 4-1990]
The building sewer shall be brought to the building at an elevation above the basement floor.
No person shall make connection of roof downspouts, exterior foundation drains, areaway drains or other sources of surface runoff or groundwater to a building sewer or building drain which in turn is connected directly or indirectly to a public sanitary sewer.
[Amended 7-15-1985 by L.L. No. 22-1985]
The connection of the building sewer into the public sewer shall conform to the requirements of the New York State Uniform Fire Prevention and Building Code. All such connections shall be made gastight and watertight. Any deviation from the prescribed procedures and materials must be approved by the Village before installation.
[Amended 7-15-1985 by L.L. No. 22-1985]
The applicant for the building permit shall notify the Superintendent, prior to placing backfill, when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Superintendent or his representative.
All excavations for building sewer installations shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of work shall be restored in a manner satisfactory to the Village.
[Added 7-15-1985 by L.L. No. 22-1985]
When any building sewer is to serve a school, hospital or similar institution or public building or is to serve a complex of industrial or commercial buildings or which, in the opinion of the Superintendent, will receive sewage or industrial wastes of such volume or character that frequent maintenance of said building sewer is anticipated, then such building sewer shall be connected to the public sewer through a manhole. The Superintendent shall determine if and where this type of connection to the public sewer is required and recommend procedures for its installation. The new manhole shall then be installed in the public sewer at the owner's expense and the building sewer connection made thereto under the supervision of the Superintendent or his representative.
[Added 7-15-1985 by L.L. No. 22-1985]
The Village reserves the right to perform all construction activity related to public sewers; and building sewers within street rights-of-way or easements. All costs for such activity are to be borne by the owner.
[Added 7-15-1985 by L.L. No. 22-1985]
Building sewers shall be serviced and repaired entirely by the owner of the property being served.
[Added 7-15-1985 by L.L. No. 22-1985]
There shall be an accessible cleanout on the building drain near the junction with the building sewer outside the building or at a wye branch fitting or building tap immediately inside the building.