Type of Use
|
Minimum Number of Off-Street Parking Spaces
| |
---|---|---|
Residential Uses
| ||
Residential, one-family
|
2 for each dwelling unit
| |
Multiple-family
|
1.5 spaces for each efficiency or 1 bedroom
unit; 2 spaces for each unit containing 2 or more bedrooms; plus 0.5
spaces per unit shall be provided for visitor parking
| |
Mobile home park
|
2 for each mobile home pad and 1 for each employee
of the mobile home park
| |
Family day-care home
|
2 plus 1 for each nonresident employee
| |
Group day-care home
|
2 plus 1 for each employee In addition, a designated
dropoff area is required
| |
Institutional Uses
| ||
Places of worship
|
1 for each 3 seats or 6 feet of pew in the main
area of worship
| |
Convalescent homes and nursing homes
|
1 for every 4 persons in residence plus 1 for
each employee in the largest working shift
| |
Hospitals/health care centers
|
1 for each 1 bed
| |
Nursery schools\day-care centers
|
1 for each 350 square feet of usable floor plus
1 designated off-street loading space for children entering and leaving
the facility
| |
Private clubs, or lodges halls
|
1 per 100 square feet of usable floor area
| |
Private golf clubs, swim clubs,
tennis clubs, or other similar uses
|
1 for every 2 member families or individuals,
plus additional spaces for accessory uses
| |
Golf courses open to the general
public except miniature courses
|
6 for each golf hole and 1 for each employee,
plus spaces required for each accessory use such as a restaurant or
bar
| |
Elementary or junior high schools
|
1 for each 1 teacher, employee, or administrator
plus the requirements for an auditorium or stadium In addition, 5
spaces shall be provided for visitor parking
| |
High schools
|
1 for each teacher, employee or administrator,
and 1 for each 5 students, plus the requirements for an auditorium
or stadium In addition, 10 spaces shall be provided for visitor parking
| |
Stadium or sports arenas or similar
outdoor place of assembly
|
1 for each 3 seats or 6 feet of benches
| |
Theaters and auditoriums
|
1 for each 3 seats plus 1 for every 2 employees
| |
Library or museum
|
1 for each 400 square feet of usable floor space
| |
Veterinary hospitals or clinics
|
1 for each 25 square feet of usable floor space in waiting rooms,
plus 1 for each exam room or similar use area
| |
Commercial Uses
| ||
Amusement arcade
|
1 for each 1 game table and 1 for each amusement
device
| |
Athletic clubs, exercise establishments,
health studios, sauna baths, martial arts studios and other similar
uses
|
1 parking space for each 3 persons allowed within
the maximum occupancy load as established by local, county or state
fire, building or health codes, plus 1 space per employee In those
instances where memberships are provided for, not less than 1 space
per each 5 memberships shall be provided, plus 1 space per employee
| |
Auto repair
|
2 per each service stall, rack or pit and 1 per employee
| |
Auto service stations (self serve)
|
In addition to space provided for vehicles being
fueled, 1 stacking space per fueling station shall be provided. 1
parking space shall be provided for each 50 square feet of usable
floor area in the cashier’s and office areas. In no instance
shall such a facility provide less than 3 parking spaces. In no instance
shall a required parking space or its maneuvering area conflict with
vehicles being fueled or awaiting fuel. In addition, parking for accessory
uses, such as mini-markets, must be provided.
| |
Auto wash (automatic).
|
1 for each 1 employee
| |
Auto wash (self-washing or coin-operated)
|
3 for each stall in addition to the stall itself
| |
Beauty parlor, barbershop, or salon
|
1.5 spaces for each chair or station, plus 1
for each employee
| |
Bowling alleys
|
4 for each bowling lane plus parking for accessory
uses such as restaurants or bars
| |
Dance halls, roller rinks, exhibition
halls and assembly halls without fixed seats
|
1 for each 3 persons allowed within the maximum
occupancy load as established by the fire marshal or health codes
| |
Establishments for sale and consumption
on the premises of beverages, food and refreshment
|
1 for each 3 persons permitted by maximum occupancy
including outdoor seating areas
| |
Funeral home or mortuaries
|
1 for each 50 square feet of usable area of
assembly room and parlors
| |
Furniture and appliance, household
equipment, repair shops, showroom of a plumber, decorator, electrician
or other similar uses
|
1 for each 800 square feet of usable floor area.
(For that floor area used in processing, 1 additional space shall
be provided for each 2 persons employed therein.)
| |
Golf driving range
|
1 space for each driving tee plus 3 spaces for
employees
| |
Hardware stores
|
1 for each 300 square feet of usable floor area
| |
Laundromats and coin-operated dry
cleaners
|
1 for each 2 machines
| |
Miniature golf courses
|
2 spaces per hole plus 5 additional spaces to
accommodate employees
| |
Motel/hotel, bed-and-breakfast
|
1 for each occupancy unit, plus 1 for each employee
| |
Motor vehicle sales establishments
|
1 for each 200 square feet of usable floor area
of sales room, plus 1 for each auto service stall in the service room
if provided
| |
Pool hall or club
|
1 for each 3 persons allowed within the maximum
occupancy load as established by the Fire Marshal
| |
Restaurants, carry-out (with no
eating on premises)
|
1 for each employee and 1 for each 60 square
feet of usable floor area with a minimum of 4 spaces
| |
Restaurants, drive-in
|
1 for each employee and 1 for each 25 square
feet of usable floor area
| |
Retail stores except as otherwise
specified herein
|
1 for each 250 square feet of usable floor area
| |
Self-storage rental
|
1 space for each employee and 1 space for each
50 storage rental units
| |
Shopping centers and super markets
|
1 for each 250 square feet of usable floor area
| |
Mini storage buildings
[Added 10-20-2003 by Ord. No. 281] |
1 space for each 30 units that do not have direct
access from outside the building or directly from a vehicular aisle
within the building, and 3 for the office or residence, and 1 for
each employee
| |
Office Uses
| ||
Banks
|
1 for each 200 square feet of usable floor space
| |
Business or professional offices
|
1 for each 250 square feet of usable floor space
| |
Offices of doctors, dentists, or
similar professions
|
1 for each 25 square feet of usable floor area
in waiting rooms and 1 for each examining room, dentist chair, office,
or similar use area
| |
Governmental offices
|
1 for each 250 square feet of usable floor space
| |
Industrial Uses
| ||
Industrial or research establishments
|
5 plus 1 for every 1 1/2 employees in the largest
working shift. Space shall also be provided for all construction workers
during periods of plant construction.
| |
Wholesale establishments
|
5 plus 1 for every 1 employee in the largest
working shift, or 1 for every 1,700 square feet of usable floor area,
whichever is greater
|
Parking Pattern
(degrees)
|
Aisle Width*
(feet)
|
Parking Space Length
(feet)
|
Parking Space Width
(feet)
|
Total Width of One Tier of Spaces
+ Aisle
(feet)
|
Total Width of Two Tiers of Spaces
+ Aisle
(feet)
|
---|---|---|---|---|---|
0° (parallel)
|
12
|
23
|
8
|
28
|
36
|
30° to 53°
|
12
|
20
|
8.5
|
32
|
52
|
54° to 74°
|
15
|
20
|
8.5
|
36
|
58
|
75° to 90°
|
20
|
20
|
9
|
40
|
60
|
*NOTE: The required aisle width may
be reduced by not more than four feet, provided that the depth of
each parking space shall be increased by a dimension not less than
the reduction of the aisle width for that portion of the parking area
so reduced.
|
Gross Floor Area
(square feet)
|
Number of Loading Spaces Required
| |
---|---|---|
0 to 1,400
|
1 space (9 x 20)
| |
1,401 to 20,000
|
1 space
| |
20,001 to 100,000
|
1 space, plus 1 space for each 20,000 square
feet in excess of 20,001 square feet
| |
100,000 to 500,000
|
5 spaces, plus 1 space for each 40,000 square
feet in excess of 100,001 square feet
|