A. 
Every occupied structure shall be provided with electrical facilities, fixtures, and systems that are compliant with the electrical regulations that were in effect when the structure was built, altered, or repaired, and that shall be maintained in a safe and good operating condition.
B. 
The size and usage of appliances and equipment shall serve as a basis for determining the need for additional facilities in accordance with the provisions of the Uniform Construction Code (N.J.A.C. 5:23). Dwelling units shall be served by a three-wire, 120/240-volt, single-phase electrical service having an ampere rating that is adequate for the intended load, as determined by the Code Enforcement Official.
C. 
Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the defects shall be corrected to eliminate the hazard.
A. 
All electrical equipment, wiring, and appliances shall be properly installed and maintained in a safe and approved manner.
B. 
Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every bathroom shall contain at least one receptacle outlet.
C. 
In the event of a change of occupancy, any kitchen receptacle outlet that serves countertop surfaces, any bathroom receptacle outlet, and/or any receptacle outlet in a laundry area that is within six feet of the edge of a sink that does not currently provide ground-fault circuit interrupter protection shall be upgraded to provide such protection. Any new kitchen receptacle outlet that serves countertop surfaces, any new bathroom receptacle, and/or any new receptacle outlet in a laundry area that is within six feet of the edge of a sink outlet shall provide ground-fault circuit interrupter protection.
D. 
Every public hall, interior stairway, kitchen, toilet room, bathroom, laundry room, boiler room, and furnace room shall contain at least one electric lighting fixture.