A hydraulic design report shall be prepared by an
engineer licensed in the State of New York. The report shall contain
design information for all highway or public easement drainage structures,
storm sewers and channels, and shall be approved by the Highway Superintendent
and the Town Engineer. The report should contain the basic design
data required to arrive at each drainage structure size, such as design
year storm, flow rate, grade, velocity, and method used to determine
the waterway size. A consideration should also be given to anticipated
(if any) future development and any urbanization of the area. The
report must address "before" and "after" development drainage conditions
and assess the downstream effects, if any, caused by the development.
The design year storm shall be a twenty-four-hour, twenty-five-year
event for the piping system, and one-hundred-year for all holding,
retention or detention facilities and stream crossings.