Street Type
|
Right-of-Way
(feet)
|
Cartway
(feet)
|
Sidewalks Required and Width
|
Parking Permitted in Right-of-Way
| |
---|---|---|---|---|---|
Industrial
|
60
|
40
|
No
|
No
| |
Arterial
|
80
|
50
|
Yes (5 feet)
|
No
| |
Collector
|
60
|
40
|
Yes (5 feet)
|
Yes
| |
Minor
|
50
|
34
|
Yes (4 feet)
|
Yes
| |
Internal (see below)*
|
*NOTE: The right-of-way for internal roads and
alleys in multifamily, commercial and industrial developments shall
be determined on an individual basis and shall be subject to approval
by the Planning Board, but in no case shall they be less than 33 feet.
|
Street Type
|
Bituminous Concrete Surface
|
Bituminous Stabilized Base Course
|
Subbase
| |
---|---|---|---|---|
Industrial
|
2-inch FABC-1
|
6-inch
|
(see below)
| |
Arterial
|
2-inch FABC-1
|
6-inch
|
(see below)
| |
Collector
|
2-inch FABC-1
|
6-inch
|
(see below)
| |
Minor
|
2-inch FABC-1
|
5-inch
|
(see below)
|
Lot Type
|
Bituminous Concrete Surface
|
Bituminous Stabilized Base
|
Quarrya Blend
Stone Base
|
Subbase
| |
---|---|---|---|---|---|
Residential
|
2-inch FABC-1
|
---
|
6-inch
|
(see below)
| |
Commercial
|
2-inch FABC-1
|
5-inch or
|
6-inch
|
(see below)
| |
Industrial
|
2-inch FABC-1
|
5-inch
|
(see below)
|
NOTES:
| ||||||
---|---|---|---|---|---|---|
a
|
Quarry blend stone base shall not be NJDOT Type
5A.
| |||||
b
|
Base course as determined by the Board Engineer,
depending upon loading.
|
Horizontal Distance
(feet)
|
Elevation Differential
(inches)
| |
---|---|---|
0 - 10
|
12
| |
11 - 20
|
16
| |
21 - 30
|
20
| |
31 or more
|
24
|
Sand
|
2.000 - 0.050 mm
|
40% - 80%
| |
Silt
|
0.050 - 0.005 mm
|
10% - 30%
| |
Clay
|
0.005 mm and smaller
|
10% - 30%
|
Number of Dwelling Units
|
Playground
|
Tennis, Basketball or Hockey Courts
|
Baseball, Soccer or Football Fields
| |
---|---|---|---|---|
1 - 9
|
--
|
--
|
--
| |
10 - 25
|
1
|
--
|
--
| |
26 - 100
|
1
|
1
|
--
| |
101 - 150
|
1
|
2
|
--
| |
151 - 200
|
1
|
3
|
1
| |
201 - 300
|
2
|
4
|
1
| |
301 - 350
|
2
|
5
|
2
| |
351 - 400
|
3
|
6
|
2
| |
401 or more
|
*
|
*
|
**
|
NOTES:
| ||
---|---|---|
*
|
One additional for every 100 units or fraction
thereof over 400.
| |
**
|
One additional for every 200 units or fraction
thereof over 400.
|
Minimum Container Capacity Requirements for Weekly Recycling
Service
| |||
---|---|---|---|
Dual Stream Collection
|
Fiber
(paper and cardboard)
|
Commingled
(bottles and cans)
| |
Non-age-restricted complex
|
One cubic yard of capacity for every 15 dwelling units
|
0.47 cubic yards (96 gallons) of capacity for every 18 dwelling
units
| |
Age-restricted complex
|
One cubic yard of capacity for every 20 dwelling units
|
0.47 cubic yards (96 gallons) of capacity for every 24 dwelling
units
| |
Single Stream Collection
|
Fiber and Commingled
|
--
| |
Non-age restricted complex
|
2 cubic yards of capacity for every 20 units
|
--
| |
Age-restricted complex
|
1.4 cubic yards of capacity for every 20 units
|
--
|
Common Container Dimensions
| ||||
---|---|---|---|---|
Size
|
Length
(inches)
|
Width
(inches)
|
Height
(inches)
| |
1 cubic yard
|
72
|
24
|
29
| |
2 cubic yards
|
72
|
34
|
45 (rear) / 34 (front)
| |
3 cubic yards
|
72
|
43
|
48 (rear) / 40 (front)
| |
4 cubic yards
|
72
|
51
|
56 (rear) / 46 (front)
| |
6 cubic yards
|
80
|
66
|
71 (rear) / 47 (front)
| |
8 cubic yards
|
80
|
71
|
86 (rear) / 53 (front)
|