Table 360-23A: Determination of Clear Sight Triangle
| |
---|---|
Width of Pavement of the Wider Intersecting Street
(feet)
|
Distance Along Center Line From Intersection
(feet)
|
Less than 29
|
30
|
30 to 39
|
40
|
40 to 49
|
50
|
50 to 59
|
60
|
60 to 69
|
70
|
Table 360-25N
| |||||
---|---|---|---|---|---|
Type
|
Maximum Gross Area per Sign
(square feet)
|
Maximum Number per Business or Service
|
Notes
|
Permit Required
| |
Awning
|
Not allowed
| ||||
Freestanding
| |||||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Bulletin or announcement boards
|
20
|
1 per street frontage
|
Yes
| ||
Marquee
|
Not allowed
| ||||
Projecting
|
3
|
1
|
See § 360-25J(4)
|
Yes
| |
Time-limited
|
6
|
2
|
No
| ||
Wall
|
1
| ||||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Bulletin or announcement boards
|
20
|
1 per street frontage
|
Yes
| ||
Shopping, office, or commercial center signs
|
20
|
2 (1 on building sign, 1 near entrance). 1 per business or service
near entrance
|
See § 360-25I(6)
|
Yes
| |
All other uses
|
3
|
1
|
Yes
| ||
Window
|
Not allowed (except for political signs and for sale/rent signs)
|
Table 360-25O
| |||||
---|---|---|---|---|---|
Type
|
Maximum Gross Area per Sign
(square feet)
|
Maximum Number per Business or Service
|
Notes
|
Permit Required
| |
Awning
|
1 per linear foot of business or service frontage
|
Clearance of 6 feet, 9 inches
|
Yes
| ||
Freestanding
| |||||
Address and/or nameplate
|
2
|
1
|
See § 360-25I(1)
|
No
| |
One use
|
2
|
1
|
Maximum height: 9 feet above finish grade to top of sign
|
Yes
| |
Two or more distinct and separate uses
|
4
|
1
|
Yes
| ||
Marquee
|
1 per linear foot of business or service frontage
|
See § 360-25J(3)
|
Yes
| ||
Projecting
|
9
|
See § 360-25J(4)
|
Yes
| ||
Time-limited
|
6
|
2
|
See § 360-25J(4)
|
No
| |
Wall
|
1 per linear foot of business or service frontage
|
1
|
See § 360-25J(5)
|
Yes
| |
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Shopping, office, or commercial center signs
|
1 per building listing businesses, 1 per business or service
near entrance
|
2 (1 on building sign, 1 near entrance)
|
See § 360-25I(6)
|
Yes
| |
Bed-and-breakfast
|
2
|
1
|
Yes
| ||
Bulletin or announcement boards
|
20
|
1 per street frontage
|
Yes
| ||
Home occupation
|
2
|
1
|
Yes
| ||
Window
|
30% of glass area
|
See § 360-25J(6)
|
Yes
|
Table 360-25P
| |||||
---|---|---|---|---|---|
Type
|
Maximum Gross Area per Sign
(square feet)
|
Maximum Number per Business or Service
|
Notes
|
Permit Required
| |
Awning
|
1 per linear foot of business or service frontage
|
1
|
Clearance of 6 feet, 9 inches
|
Yes
| |
Freestanding
| |||||
Address
|
Not allowed
| ||||
One use
|
2
|
1
|
Maximum height: 9 feet above finish grade to top of sign
|
Yes
| |
Two or more distinct and separate uses
|
4
|
1
|
Yes
| ||
Sidewalk
|
2 feet by 3.5 feet high when opened
|
1
|
No more than one foot from building. On-site only
|
Yes
| |
Marquee
|
1 per linear foot of business or service frontage
|
1
|
See § 360-25I(5)
|
Yes
| |
Projecting
|
9
|
1
|
See § 360-25I(7)
|
Yes
| |
Time-limited
|
6
|
2
|
See § 360-25J(4)
|
No
| |
Wall
|
1 per linear foot of business or service frontage
|
1
|
See § 360-25I(9)
|
Yes
| |
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Bed-and-breakfast
|
2
|
1
|
Yes
| ||
Bulletin or announcement boards
|
20
|
1 per street frontage
|
Yes
| ||
Home occupation
|
2
|
1
|
Yes
| ||
Window
|
30% of glass area
|
See § 360-25I(10)
|
Yes
|
Table 360-25Q
| |||||
---|---|---|---|---|---|
Type
|
Maximum Gross Area per Sign
(square feet)
|
Maximum Number per Business or Service
|
Notes
|
Permit Required
| |
Awning
|
1 per linear foot of business or service frontage
|
Clearance of 6 feet, 9 inches
|
Yes
| ||
Freestanding
| |||||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
One or two distinct and separate uses
|
30
|
1
|
Maximum height: 9 feet above finish grade to top of sign
|
Yes
| |
Three or more distinct and separate uses
|
60
|
1
|
Maximum height: 15 feet above finish grade to top of sign
|
Yes
| |
Marquee
|
2 per linear foot of business or service frontage
|
See § 360-25I(5)
|
Yes
| ||
Projecting
|
9
|
See § 360-25I(7)
|
Yes
| ||
Time-limited
|
6
|
2
|
No
| ||
Wall
|
2 per linear foot of business or service frontage
|
Yes
| |||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Shopping, office, or commercial center signs
|
1 per building listing businesses, 1 per business or service
near entrance
|
2 (1 on building sign, 1 near entrance)
|
See § 360-25I(6)
|
Yes
| |
Window
|
30% of glass area
|
See § 360-25I(10)
|
No
|
Table 360-25R
| |||||
---|---|---|---|---|---|
Type
|
Maximum Gross Area per Sign
(square feet)
|
Maximum Number per Business or Service
|
Notes
|
Permit Required
| |
Awning
|
1 per linear foot of business or service frontage
|
Clearance of 6 feet, 9 inches
|
Yes
| ||
Freestanding
| |||||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
One or two distinct and separate uses
|
15
|
1
|
Maximum height: 9 feet above finish grade to top of sign
|
Yes
| |
Three or more distinct and separate uses
|
24
|
1
| |||
Marquee
|
1 per linear foot of business or service frontage
|
See § 360-25I(5)
|
Yes
| ||
Projecting
|
9
|
See § 360-25I(7)
|
Yes
| ||
Time-limited
|
6
|
2
|
No
| ||
Wall
|
1 per linear foot of business or service frontage
|
Yes
| |||
Address
|
2
|
1
|
See § 360-25I(1)
|
No
| |
Window
|
30% of glass area
|
See § 360-25I(10)
|
No
|
Table 360-26B(2)
Handicapped Parking Requirements
| |||
---|---|---|---|
Total Parking Spaces Provided
|
Minimum Number of Accessible Spaces
|
Minimum Number of Van-Accessible Spaces
|
Minimum Number of Car-Accessible Spaces
|
6 through 12
|
1
|
1
|
0
|
13 through 35
|
2
|
1
|
1
|
36 through 50
|
3
|
1
|
2
|
51 through 75
|
4
|
1
|
3
|
76 through 100
|
5
|
1
|
4
|
101 through 150
|
6
|
1
|
5
|
151 through 200
|
7
|
1
|
6
|
201 through 300
|
8
|
2
|
6
|
301 through 400
|
9
|
2
|
7
|
401 through 500
|
10
|
2
|
8
|
Table 360-26F(1) - Stacking Requirements
| ||
---|---|---|
Activity Type
|
Minimum Stacking Spaces
|
Measured From
|
Bank teller lane
|
4
|
Teller or window
|
Automated teller machine
|
3
|
Teller machine
|
Restaurant drive-through
|
6
|
Order box
|
Restaurant drive-through
|
4
|
Order box to pickup window
|
Car wash stall, automatic
|
6
|
Entrance
|
Car wash stall, self-service
|
3
|
Entrance
|
Gasoline pump island
|
2
|
Pump island
|
Other (as determined by Borough)
|
Determined by parking study supplied by applicant
|
Table 360-26G — Loading Space Requirements
| |
---|---|
Type of Use
|
Number of Loading Spaces per Square Foot of Total Floor
Area
|
Commercial, including warehouses
|
1 space per 10,000 square feet GFA* or fraction thereof
|
Industrial, transportation
|
1 space per 20,000 square feet GFA* or fraction thereof
|
Public and recreational uses**
|
1 space per 40,000 square feet GFA* or fraction thereof (unless
under 10,000 square feet GFA in which case no loading space is required)
|
NOTES:
| |
---|---|
*
|
See Article II, Definitions: Floor Area, Gross (GFA)
|
**
|
In calculating the number of spaces required for public and
recreational spaces the square footage of roofed structures, not of
open fields, needs to be considered.
|
Table 360-29A - Outdoor Area Lighting Standards
| |||
---|---|---|---|
Zoning District
|
Maximum Permitted Illumination at the Property Line
(footcandles)
|
Maintain Minimum Illumination in Parking and Pedestrian
Areas
(footcandles)
|
Maximum Permitted Height of Luminaire
(feet)
|
Highway Commercial (HC)
|
0.5 (0.1 where adjoining a private property line in a residential
district)
|
0.2
|
20
|
Downtown Commercial (DC)
|
0.5 (0.1 where adjoining a private property line in a residential
district)
|
0.2
|
20
|
RS, RT1, RT2, RT3
|
0.1
|
0.2 (commercial parking areas only)
|
12 feet
|
Bucknell University District (BU)
|
0.5 (0.1 where adjoining a noncampus residential property)
|
0.2
|
12
|
Mixed Use District (MU)
|
0.5 (0.1 where adjoining a private property line in a residential
district)
|
0.2
|
20
|
Open Space (OS)
|
0.5 (0.1 where adjoining a private property line in a residential
district)
|
0.2 (in parking areas only)
|
At the discretion of Borough Council
|
NOTES:
| |
---|---|
1
|
The maximum permitted illumination is measured in footcandles
at the property lines at ground level.
|
2
|
Light illuminating the living space of balconies of multistory
buildings shall not be subject to the twelve-foot height limitation.
Such lighting shall not include flood, spot or directional lighting
and shall be shielded so that neither light trespass nor glare occurs.
|