R-1
|
R-2
|
R-3
|
RR
|
P-1
| |
---|---|---|---|---|---|
Maximum lot coverage
|
35%
|
35%
|
40%
|
40%
| |
Maximum building height
(feet)
|
30
|
30
|
40
|
30
|
|
Minimum lot width (a)
1-family
2-family
Multifamily
Other
|
*
80
|
*
60
75(b)
|
*
60
75(b)
70(c)
|
*
80
|
*
389680
60
|
Minimum setbacks (feet)
Front yard
Rear yard
Side yard
|
25
25
10
|
20
20
8
|
20
20
8
|
25
25
10
|
20
20
8
|
Minimum lot size
(square feet)
1-family
2-family
Multifamily
Other
|
*
10,000
|
*
7,500
10,000
|
*
7,500
10,000
10,000
|
*
32,670
|
*
7,500
|
(a)
|
At the required front setback line.
|
(b)
|
Zero lot line (2-family dwelling): minimum lot width 37.5. See
Article IV, § 4.06 for additional requirements.
|
(c)
|
Except townhouses. See Article IV, § 4.05 for additional
requirements.
|
*- These standard regulations apply to lots with community water
and sewer services.
| |
- Lots with community water and individual septic tanks must
comply with fifty-foot lot width and a lot size minimum of 15,000
square feet if in existence prior to January 2013. For new lots the
minimum lot size is 3/4 of an acre for single-family dwellings and
1/2 an acre per dwelling unit for multifamily development.
| |
- Lots with individual well and septic tank must comply with
Kentucky Green River Health Department regulations.
| |
- Manufactured homes/mobile homes with community water and individual
septic tanks must comply with minimum lot size on community water
and sewer; mobile home with community water and individual septic
tanks must comply with the minimum lot size per single-family development
for placement on lots.
|
C-1
|
C-2
|
H-C
|
M-1
|
M-2
|
AG
| |
---|---|---|---|---|---|---|
Maximum lot coverage
| ||||||
Maximum building height
(feet)
|
30
|
30
|
30
|
30
|
160
| |
Minimum lot width (a)
1-family
2-family
Multifamily
Other
|
*
80
| |||||
Minimum setbacks
(feet)
Front yard
Rear yard
Side yard
|
25
|
25
|
30
20
10
|
50
25
25
|
50
25
25
|
25
25
10
|
Minimum lot size (square feet)
1-family
2-family
Multifamily
Other
|
*
|
(a)
|
At the required front setback line.
|
*- These standard regulations apply to lots with community water
and sewer services.
| |
- Lots with community water and individual septic tanks must
comply with fifty-foot lot width and a lot size minimum of 15,000
square feet if in existence prior to January 2013. For new lots the
minimum lot size is 3/4 of an acre for single-family dwellings and
1/2 an acre per dwelling unit for multifamily development.
| |
- Lots with individual well and septic tank must comply with
Kentucky Green River Health Department regulations.
| |
- Manufactured homes/mobile homes with community water and individual
septic tanks must comply with minimum lot size on community water
and sewer; mobile home with community water and individual septic
tanks must comply with the minimum lot size per single family development
for placement on lots.
|