6.1.1.
Applicability. No new building designated or intended to be used for any of the uses referred to below shall be constructed in any district unless accessory parking spaces are provided and maintained on the premises in the amount specified below and in accordance with the other requirements of this section.
6.1.2.
Table of Parking Requirements. The following requirements shall apply; provided, however, that in Zoning District B, there shall be no off-street parking required for permitted uses in existing buildings which are remodeled but not substantially expanded, as defined in Section 9.5.2:
Principal Use | Parking Space Requirement |
|---|---|
Dwelling unit, except as otherwise provided in this bylaw | 2 parking spaces |
Lodging house | 1 parking space for each 2 guests |
Hotel, motel or overnight cabin | 1 parking space for each sleeping room |
Hospital | 1 parking space for each bed |
Nursing or convalescent home | 1 parking space for each 3 beds, plus 2 spaces for each 3 employees serving on the shift having the greatest number of employees |
Retail and/or wholesale sales and service establishment | 1 space for each 200 square feet of net usable floor area |
Offices, banks and other financial institutions or professional buildings (other than medical or dental) | 1 space for each 300 square feet of net usable floor area |
Professional offices, medical, dental or similar use | 5 spaces for each professional occupant in building |
Restaurant | 1 space for each 3 seats |
Theaters and other places of assembly | 1 space for each 4 seats |
Industrial uses | 1 parking space for each 2 employees, computed on the basis of the estimated maximum number of employees at any one time |
Mixed uses | The sum of the requirements for the individual uses; when other provisions specify fewer parking spaces for specific uses, the less restrictive shall apply |
6.1.3.
Location. Any parking area of more than five spaces providing off-street parking under the provisions of this bylaw for any nonresidential use in a residence district shall not be located in the required front yard and shall be at least 10 feet from any side or rear lot line. If a nonresidential use in a residence district is located on a corner lot, no parking area of more than five spaces shall be located within the designated front yard nor closer to the street line than twice the required setback for residences within that district in side and rear yards. In the B2 Zone, no parking spaces provided for new or replacement structures shall be located between the structure and the front lot line.
6.1.4.
Size of parking space. The net area of each parking space, exclusive of access and maneuvering area, shall not be less than 180 square feet and the width of each parking berth shall not be less than nine feet, and shall be delineated on site. Up to 20% of the required parking spaces may be designed as compact car spaces. Any compact car spaces must be clearly designated as such on the site plan, and appropriate markings and signage must be installed on-site. Handicap parking spaces must meet Commonwealth of Massachusetts and American Disabilities Act requirements.
6.1.5.
Interpretation of fractional space. When the application of a unit of measurement for parking spaces to a particular use or structure results in a fractional space, any fraction under 1/2 shall be disregarded, and fractions of 1/2 or over shall be counted as one parking space.
6.1.6.
Table of Loading Requirements. No new building designed or intended to be used for any of the uses referred to below shall be constructed in any district unless accessory loading space is provided in accordance with the following requirements:
Principal Use | Loading Requirement |
|---|---|
Any retail or service establishment, office building or hotel with 5,000 to 8,000 square feet of gross floor area devoted to any such uses | 1 loading space |
Same, with 8,000 to 20,000 square feet gross floor area devoted to any such uses | 2 loading spaces |
Same, each additional 20,000 square feet of gross floor area devoted to any such uses | 1 additional loading space |
Any manufacturing, industrial or storage establishment with over 5,000 square feet of gross floor area | Loading space adequate, in the opinion of the Inspector of Buildings, to accommodate the normal demands incidental to the proposed use of the premises |
6.1.7.
Size of loading berth. The area of each loading berth shall be not less than 200 square feet, and it shall have a minimum clear height, including access to it from a street, of 14 feet.
6.1.8.
Joint facilities. Accessory parking spaces or loading spaces for commercial and manufacturing uses may be provided in facilities designed to serve jointly two or more buildings or uses, provided that the number of berths in such joint facilities shall not be less than the total required under the provisions of this section.
6.1.9.
Special permit. The Planning Board may, by special permit pursuant to Section 10.4, authorize a deviation from any parking or loading requirement set forth in this Section 6.1. In instances where an application is pending before a different special permit granting authority, that body may, in accord with a finding by the Planning Board, authorize the deviation from the requirements of Section 6.1.