4.1.1.
Conformance. No building or structure shall be built nor shall any existing building or structure be enlarged which does not conform to the Table of Dimensional Requirements, except as may be otherwise provided.
District | Max. Floor Area Ratio | Min. Lot Area (sq. ft.) | Min. Lot Area Per D.U. (sq. ft.) | Min. Yard (ft.) | Min. Lot Front-age and Lot Width (ft.) | Green Area Open Space Per D.U. (sq. ft.) | Max. Num-ber Stories | ||
|---|---|---|---|---|---|---|---|---|---|
Front | Side | Rear | |||||||
Res. A | None | 7,650 | 7,650 | 251 | 13 | 20 | 85 | None | 2.5 |
Res .B | |||||||||
1 to 3 units | 0.4 | 6,750 | 3,000 | 25 | 13 | 25 | 75 | 700 | 3 |
4 to 5 units | 0.4 | 6,750 | 4,000 | 25 | 25 | 25 | 75 | 700 | 3 |
6 to 16 units | 0.5 | 6,750 | 4,500 | 25 | 25 | 25 | 75 | 1,000 | 3 |
17 units and up | 0.5 | 6,750 | 4,500 | 25 | 25 | 25 | 75 | 1,000 | 3 |
Res. C | 1 | 14,000 | 2,000 | 1/2 the height of the building but in no case less than 25 | 100 | 400 | 6 | ||
Bus. A2 | 0.75 | 5,000 | None | 15 | 15 | 15 | 40 | None | 3 |
Bus. B2 | 1.5 | 5,000 | None | 153 | 15 | 20 | 60 | None | 4 |
Bus. C2 | 3.5 | 5,000 | None | None | None | 20 | 60 | None | 6 |
Ind. A | 1 | None | None | 253 | 253 | 253 | 50 | None | 4 |
Ind. B | 2 | None | None | 253 | 253 | 253 | 50 | None | 8 |
4.1.2.
Notes to table. The Table of Dimensional Requirements does not contain any requirements for the Open Space, Planned Unit Development, Planned Unit Development 1, and Downtown Districts. See Section 8.0 for these requirements.
1.
In Residence A Districts buildings shall be set back so as to conform to the average alignment of dwellings already erected on the same side of the street within 300 feet on each side of the lot, except that no building shall be set back less than 25 feet and no building shall be set back more than 55 feet.
2.
Multifamily residence and mixed use of a building are permitted within a Business A and B District with the issuance of a special permit in accordance with the standards and procedures of Section 9.4 by the Zoning Board of Appeals. Residential buildings and uses within Business A Districts obtaining special permit, as provided herein, shall conform to all requirements of Residential B Districts. Residential buildings and uses within Business B Districts obtaining special permits, as provided herein, shall conform to all the requirements of Residence C Districts. Multifamily residences and mixed use of a building are permitted within a Business C District with approved site plan from the Planning Board in accordance with Section 9.5, provided that residential buildings and uses within a Business C District have a maximum floor area ratio (FAR) of 3.5, minimum lot size of 42,000 square feet, minimum lot area per dwelling unit of 500 square feet, minimum front, rear and side yards of 1/4 the height of the building, minimum lot frontage and lot width of 100 feet and minimum open space per dwelling unit of 100 square feet. The site plans of a building containing 12 units or more must be reviewed by the Planning Board.
[Amended 6-1-2020 by Order No. 2020-012]
3.
Applies only to buildings hereafter constructed.
4.
Notwithstanding the number of allowable stories, no residential building shall be more than 60 feet above the existing average grade; buildings with commercial uses shall not be more than 80 feet above existing average grade. In no case shall any building exceed six stories. Any commercial building with residential housing will be subject to the six-story above-grade limitation. These amendments shall not apply to any buildings for which a permit to construct a foundation was issued prior to January 1, 1987.
[Amended 6-1-2020 by Order No. 2020-012]
5.
In a Residential A and B District, no residential building, notwithstanding the number of allowable stories, shall exceed 35 feet in height, measured from the highest point of the structure to the average existing finished grade at the footprint of the building, notwithstanding the definition of "height."
[Amended 6-1-2020 by Order No. 2020-012]