The following definitions shall
apply in the interpretation and enforcement of this Article:
AIR-GAP SEPARATION
The unobstructed vertical distance through the free atmosphere
between the lowest opening from any pipe or faucet supplying water
to a tank, plumbing fixture, or other device and the overflow level
rim of the receptacle, and shall be at least double the diameter of
the supply pipe measured vertically above the flood level rim of the
vessel, but in no case less than one (1) inch.
AUXILIARY WATER SUPPLY
Any water source or system, other than the public water supply,
that may be available in the building or premises.
BACKFLOW
The flow other than the intended direction of flow, of any
foreign liquids, gases, or substances into the distribution system
of a public water supply.
CONSUMER
The owner or person in control of any premises supplied by
or in any manner connected to a public water system.
CONTAINMENT
Protection of the public water supply by installing a cross-connection
control device or air-gap separation on the main service line to a
facility.
CONTAMINATION
An impairment of the quality of the water by sewage, process
fluids, or other wastes to a degree which could create an actual hazard
to the public health through poisoning or through spread of disease
by exposure.
CROSS-CONNECTION
ny physical link between a potable water supply and any other
substance, fluid, or source, which makes possible contamination of
the potable water supply due to the reversal of flow of the water
in the piping or distribution system.
HAZARD DEGREE OF
An evaluation of the potential risk to public health and
the adverse effect of the hazard upon the potable water system.
1.
Hazard, Health: Any condition, device, or practice
in the water supply system and its operation which could create or
may create a danger to the health and well-being of the water consumer.
2.
Hazard, Plumbing: A plumbing type cross-connection
in a consumer's potable water system that has not been properly protected
by a vacuum breaker, air-gap separation or backflow prevention device.
3.
Hazard, Pollutional: An actual or potential
threat to the physical properties of the water system or to the potability
of the public or the consumer's potable water system but which would
constitute a nuisance or be aesthetically objectionable or could cause
damage to the system or its appurtenances, but would not be dangerous
to health.
4.
Hazard, System: An actual or potential threat
of severe damage to the physical properties of the public potable
water system or the consumer's potable water system, or of a pollution
or contamination which would have a protracted effect on the quality
of the potable water in the system.
INDUSTRIAL PROCESS SYSTEM
Any system containing a fluid or solution, which may be chemically,
biologically, or otherwise contaminated or polluted in a form or concentration
such as would constitute a health, system, pollutional, or plumbing
hazard if introduced into a potable water supply.
ISOLATION
Protection of a facility service line by installing a cross-connection
control device or air-gap separation on an individual fixture, appurtenance,
or system.
POLLUTION
The presence of any foreign substance (organic, inorganic,
or biological) in water which tends to degrade its quality so as to
constitute a hazard or impair the usefulness of the water to a degree
which does not create an actual hazard to the public health but which
does adversely and unreasonably affect such waters for domestic use.
PUBLIC POTABLE WATER SYSTEM
Any publicly or privately owned water system supplying water
to the general public which is satisfactory for drinking, culinary,
and domestic purposes and meets the requirements of the Missouri Department
of Natural Resources.
SERVICE CONNECTION
The terminal end of a service line from the public water
system. If a meter is installed at the end of the service, then the
service connection means the downstream end of the meter.
WATER PURVEYOR
The owner, operator, or individual in responsible charge
of a public water system.