A.
No unauthorized person shall uncover, make any connections with or opening into, use, alter, or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the Department of Public Works. No property, or portion of a property, located outside the sewer service area shall be allowed to extend or construct a sanitary sewer. There must be sufficient available capacity to accommodate the proposed expansion. Any person proposing a new discharge into the system or a substantial change in the volume or character of pollutants that are being discharged into the system shall notify the Department at least 45 days prior to the proposed change or connection. (See Appendix F, Forms.)
B.
Connection permits. There shall be three classes of building sewer permits: 1) single-family residential, 2) multifamily and commercial, and 3) industrial. In each case, the owner or his agent shall make application on a special form furnished by the Town and shall meet all conditions of said permit as detailed on the form (see Appendix F, Forms). The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the Commissioners. Approval of commercial and industrial permits must be obtained from the Commissioners of either Leominster or Fitchburg, after review and recommendation by the Commission, before a permit can be issued.
C.
Application to connect or reconnect to the sewer must be made in person by the installing contractor representing the property owner. Any application for a sewer connection to a commercial or industrial building must be accompanied by a sewer clearance plan showing the following:
(1)
All invert elevations of proposed connections at building and street.
(2)
Street center line elevation.
(3)
Building sill elevation.
(4)
Plan stamped by a registered professional engineer with Massachusetts certification.
(5)
All connections showing any water, sewer, drainage connections.
(6)
Building location on lot.
(7)
All wetlands shown, if applicable. If not applicable, submit written statement noting that no wetlands exist on lot.
(8)
Building setback distances shown from each lot line.
(9)
Driveway location center-line grades indicating pitch of driveway.
(10)
Scale: one inch equals 40 feet. Plan size 8 1/2 by 11 only.
(11)
Any drainage connections that may be required must be shown. Any perimeter drain is not allowed to transit, by any means, water onto Town streets. It must be shown on the clearance plan where the perimeter drain will discharge.
(12)
Water pressure which will service the building must be designated on the plan.
(13)
Sewer flow calculation must be shown on all commercial and industrial connections based on Title V regulations.
D.
Extensions.
(1)
All sewer extensions to the existing main must be approved by the Commission. Any proposed extension in excess of 1,000 linear feet must be submitted to the DEP for approval.
(2)
Any proposed extension of the sewer main that lies outside the sewer service area entirely or in part requires approval of the Commission as well as a Town Meeting vote to extend the sewer service area and, if applicable, the DEP as described herein.
E.
Sewer connection permits associated with new construction/additions. Permits issued hereunder shall terminate upon expiration of the building permit.