In addition to the general requirements of Article
IV, the requirements of this article apply to all development proposed in special flood hazard areas other than coastal high hazard areas. These areas include Zones A, AE, and AO.
Accessory structures shall meet the requirements of these regulations.
Accessory structures that have a footprint of no more than 200 square
feet may be allowed without requiring elevation or floodproofing,
provided such structures meet all of the following requirements:
A. Usable only for parking or limited storage;
B. Constructed with flood-damage-resistant materials below the base
flood elevation;
C. Constructed and placed to offer the minimum resistance to the flow
of floodwaters;
D. Firmly anchored to prevent flotation, collapse, and lateral movement;
E. Electrical service and mechanical equipment elevated to or above
the level of the base flood elevation; and
F. Equipped with flood openings that meet the requirements of §
71-26B.
G. For guidance, see FEMA Technical Bulletin No. 7 - Wet Floodproofing
Requirements.