[Ord. No. 11.009 §1, 11-9-2016[1]]
A. 
Adoption. The International Building Code®, 2012 Edition, as published by the International Code Council, Inc., including:
Appendix Chapter C: Group U - Agricultural Buildings.
Appendix Chapter G: Flood-Resistant Construction.
Appendix Chapter I: Patio Covers.
Appendix Chapter J: Grading.
is hereby enacted and made part of this Section by reference except as to portions hereinafter specifically deleted, clarified or amended.
B. 
If any conflict should exist between the International Building Code and the Zoning Regulations Code of the City of Weston, Missouri, the provisions of the Zoning Regulations Code shall control. If any conflict should exist between the International Building Code and any other ordinance of the City of Weston, Missouri, the International Building Code provisions shall control and the portion of the ordinance in conflict with the International Building Code provision shall be repealed. Such repeal will affect only that portion of any ordinance which is in conflict with the International Building Code and shall not affect any other portions of the ordinance.
C. 
The following changes shall be made in the International Building Code:
1. 
Amend Subsection 101.1, "Title" by adding the following: "City of Weston, Missouri."
2. 
Amend Subsection 107.1, "General" by deleting the following: ". . . where required by the statutes of the jurisdiction in which the project is to be constructed."
3. 
Delete Subsection 109.6, "Refunds" in its entirety.
4. 
Delete Subsection 113, "Board of Appeals" in its entirety.
5. 
Amend Subsection 406.3.4, "Separation" by deleting item 1 and replacing it with the following: "The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than five-eighths (5/8) inch thick applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a five-eighths (5/8) inch Type X gypsum board or equivalent and five-eighths (5/8) inch Type X gypsum board applied to structures supporting the separation from habitable rooms above the garage. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or honeycomb or solid core steel doors not less than one and three-eighths (1 3/8) inches in thickness or doors in compliance with Section 716.5.3 with a fire protection rating of not less than twenty (20) minutes. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Doors shall be self-closing and self-latching."
6. 
Add a new Subsection 1016.4, "Roof Vent Increase" to read as follows: "Roof vent increase. In buildings that are one (1) story in height, equipped with automatic heat and smoke roof vents complying with Section 910 and equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum exit access travel distance shall be four hundred (400) feet (122m) for occupancies in Group F-1 or S-1."
7. 
Amend Subsection 1612.3, "Establishment of Flood Hazard Areas" by inserting the following: "City of Weston, Missouri" and "April 2, 2015."
8. 
Amend Subsection 2901.1, "Scope" by deleting the last sentence: "Private sewage disposal systems shall conform to the International Private Sewage Disposal Code."
9. 
Amend Subsection 3412.2, "Applicability" by inserting the following: "June 12, 2015."
[1]
Editor's Note: Former Chapter 500, Building Codes and Building Regulations, comprised of Sections 500.010 through 500.070, derived from Ord. No. 11.005 §§1 — 7, 11-13-2007, Ord. No. 11.006 §§1 — 2, 6-14-2010 and Ord. No. 11.008 §§1 — 3, 6-12-2015, was repealed 11-9-2015 by Ord. No. 11.009.