[Amended 12-13-1995 by L.L. No. 9-1995]
A. 
The intent of this article is to provide criteria to be followed when applying to install upon or to develop a parcel of land and/or construct or modify a building under the rules specified in the Town of Ogden Code, Chapter 254, entitled "Subdivision of Land," and/or Chapter 273, entitled "Towers and Antennas," and in relation to those applications to be proposed and/or presented to any Board of the Town of Ogden: Town, Planning, Zoning and/or Conservation.
B. 
Prior to scheduling a Planning Board and/or a public meeting, drawings, sketches, specification, etc., shall be presented to the Secretary of the Planning Board for review of adequacy of documentation in accordance with this chapter.
C. 
The Secretary of the Planning Board, upon determination that drawings and specifications meet code requirements, will schedule a Planning Board and/or public meeting.
D. 
Prior to scheduling subsequent meetings on previously tabled applications, the Planning Board secretary shall determine that the new drawings have been revised and submitted in accordance with the Planning Board notice of decision and that the responses from Monroe County Planning, Town Engineer and the Town Conservation Board have been received by the Planning Board Secretary. The Planning Board Secretary may reschedule a subsequent meeting awaiting Town Engineer response.
E. 
Specifics. See design criteria adopted from time to time.
The following shall be shown on the drawing:
A. 
Location of proposed house, driveway, water supply, structure or addition, leach field location and public road center line elevation.
(1) 
General notes shall include the following statements:
(a) 
Elevation at the front of the building (finished grade) shall be at least 15 inches above the center line of the road.
(b) 
The house must be located on the lot so that a two-car garage may be built without infringing on any lot's side setback line.
(c) 
The basement floor must be above mineral deposits, unless the developer's engineer and the Town Engineer agree to a viable alternative that lowers the water table level.
(d) 
Any change in the house and/or leach field location from an approved plan must be resubmitted to the Planning Board for reapproval.
(e) 
The developer shall set lot monumentation posts at all corners and angles.
(f) 
When special districts (water, lighting, drainage, sidewalk and/or playground and park) are to be established by the Town Board, a general note stating the type of district and date of Town Board approval shall be included on the drawing.
(2) 
A change in house location not exceeding 10 feet from the approved plan and not in violation of any existing code and not affecting the leach field may be approved by the Building Inspector in the field.
(3) 
House elevation shall show both pad elevation (finished grade) and first floor elevation. The pad elevation shall be enclosed within a block located at each front house corner.
(4) 
The Planning Board has the option to request a deep hole test in the basement area when in its judgment the soil and rock conditions warrant. In every case where mineral deposits are found in the deep hole test in the septic system area, a deep hole shall be dug in the basement area and soil conditions noted. These deep hole tests are to be witnessed by Monroe County Health Department or Town Engineer and results noted.
B. 
All existing structures, abandoned foundations, wooded areas, streams, floodplains, hydrants, telephone poles with identification numbers and other significant features which are in the proposed subdivision and within 200 feet of the subdivision, including septic systems and wells on adjacent properties.
C. 
Owners' name and tax account numbers and house numbers of all adjacent property owners that border on the proposed subdivision.
D. 
Topographic contours, both existing and proposed, to be shown at intervals of one foot, except in instances of a steep grade of 6% or more; then intervals are to be every five feet. Contour lines are to extend 200 feet on all sides of the proposed subdivision.
E. 
The proposed pattern of layout of lots, with dimensions and bearings and angles, driveways, streets, recreation and green areas, drainage systems, septic systems and water supply within the proposed subdivision.
F. 
The proposed and existing buildings and all setback lines and dimensions, front, side and rear, as defined in this Code.
G. 
An actual field survey of the boundary lines of the tract, giving complete descriptive data by bearing and distances, made and certified to by a licensed land surveyor. The corners of the tract shall also be indicated on the ground and marked by monuments as approved by the Town Engineer and shall be referenced and shown on the plan.[1]
[1]
Editor's Note: Original Art. IV, Design Standards, and Art. V, Construction Standards, of the 1972 Code, which immediately followed this section, were repealed 12-13-1995 by L.L. No. 9-1995. The current Town Design Criteria and Construction Standards are on file in the Town offices.