[1]
Editor's Note: Former Art. II, Residential Code, was repealed 5-14-2016 by Ord. No. 119 § 1.
[Ord. No. 119 § 2, 5-24-2016; Ord. No. 246, 5-9-2023]
A certain document, two (2) copies of which are on file and are open for public inspection in the office of the City Clerk of the City of Fair Grove, Missouri, being marked and designated as the International Residential Code/2018, including Appendices A, B, C, D, E, G, H, J, K, M, N and Q as published by the International Code Council, be and is hereby adopted as the Residential Code of the City of Fair Grove for regulating the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of one- and two-family dwellings and town houses not more than three (3) stories in height in the City of Fair Grove; and each and all of the regulations, provisions, penalties, conditions and terms of said code are hereby referred to, adopted and made a part hereof, as if fully set out in this Chapter, with the additions, insertions, deletions and changes, if any, prescribed in Section 500.025 of this Chapter.
[Ord. No. 119 § 2, 5-24-2016; Ord. No. 246, 5-9-2023]
A. 
The International Residential Code adopted by Section 500.020 is hereby amended by substituting the following Sections or portions of Sections for those Sections or portions of Sections with corresponding numbers of the International Residential Code/2018 or where there is no corresponding Section in the code, the following Sections shall be enacted as additions to that code:
1. 
Section R101.1 Insert: "The City of Fair Grove."
2. 
Section R103 Department of Building Safety. Delete in its entirety. Insert, in lieu thereof, the following: "Refer to Section 103 of the International Building Code."
3. 
Section R113.4. Add a sentence to the end of the paragraph to read as follows: "The penalties are set forth in Section 500.100 of the Code of Ordinances of the City of Fair Grove."
4. 
Insert the following values in Table R301.2(1):
Ground snow load
20
Wind speed
90
Seismic design category
C
Damage from weathering
Severe
Frost line depth
18 inches
Damage from decay
Moderate/heavy
Winter design temperature
Flood hazard
"as hereinbefore adopted by the City of Fair Grove"
5. 
R501.3.5 Add the following exception: "No protection required when there is no mechanical equipment located in a crawl space."
6. 
Chapter 11 of the 2012 International Residential Code shall be replaced by the 2018 International Residential Code Chapter 11.
7. 
Delete Section P2503.5.2 item 2 in its entirety.
8. 
Delete Section P2503.6.
9. 
Section E3902.2 Add the following exception: "GFCI is not required if garage door opener receptacle is a single dedicated receptacle and not a duplex."
10. 
Delete entire Section E4002.14.