The delineation of any identified floodplain area may be revised
by the Board of Supervisors where natural or man-made changes have
occurred and more detailed studies conducted or undertaken by the
United States Army Corps of Engineers, River Basin Commission, or
other qualified agency or person document such changes. Prior to any
such change, approval must be obtained from the Federal Emergency
Management Agency (FEMA). Additionally, as soon as practicable, but
not later than six months after the date such information becomes
available, the Township shall notify FEMA of the changes to the Flood
Hazard District by submitting technical or scientific data.
Should a dispute concerning any identified floodplain boundary
arise, an initial determination shall be made by the Township Engineer,
and any party aggrieved by this decision or determination may appeal
to the Zoning Hearing Board. The burden of proof shall be on the appellant.
Prior to development occurring in areas where annexation or
other corporate boundary changes are proposed or have occurred, the
Township shall review flood hazard data affecting the lands subject
to boundary changes. The Township shall adopt and enforce floodplain
regulations in areas subject to annexation or corporate boundary changes
which meet or exceed those in 44 CFR 60.3.
All structures, tracts of land and water shall hereafter be
used or developed in full compliance with the provisions of this article
and any other ordinances and regulations which apply to uses within
the jurisdiction of this article. Any land-altering activity shall
not commence without first obtaining a zoning permit.
This article supersedes any other conflicting provisions which
may be in effect in identified floodplain Areas. However, any other
ordinance provisions shall remain in full force and effect to the
extent that those provisions are more restrictive. If there is any
conflict between any provisions of this article, the more restrictive
shall apply. This article shall not repeal, abrogate, or impair any
existing easements, covenants, or deed restrictions.
Lawfully existing structures and uses of land within the Flood
Hazard District shall comply with the following regulations regarding
improvements to an existing structure:
A. No expansion or enlargement of an existing structure shall be allowed within any identified floodplain area that would cause any increase in BFE. In A Area(s)/District(s), BFEs are determined using the methodology in §
170-76B(3).
B. Any modification, alteration, reconstruction, or improvement of any
kind to an existing structure to an extent or amount of 50% or more
of its market value shall constitute a substantial improvement and
shall be undertaken only in full compliance with the provisions of
this article.
C. The above activity shall also address the requirements of 34 Pa.
Code, as amended, and the 2009 IBC and the 2009 IRC or most recent
revision thereof as adopted by the Commonwealth of Pennsylvania.
D. Within any Floodway Area/District, no new construction or development
shall be allowed, unless the appropriate permit is obtained from the
Department of Environmental Protection Regional Office.
E. Within any AE Area/District without floodway, no new construction
or development shall be located within the area measured 50 feet landward
from the top-of-bank of any watercourse, unless the appropriate permit
is obtained from the Department of Environmental Protection Regional
Office.
F. Any modification, alteration, reconstruction, or improvement of any
kind to an existing structure, to an extent or amount of less than
50% of its market value, shall be elevated and/or floodproofed to
the greatest extent possible.
G. An existing structure located within the Flood Hazard District shall
not be enlarged or altered more than 50% of its present lot coverage
figure.
H. Any modification, alteration, enlargement or improvement of any kind
to an existing structure in the Flood Hazard District shall be elevated
and/or floodproofed.
The Zoning Hearing Board shall attach the following conditions
to the granting of a special exception or variance where applicable:
A. Any modification, enlargement, alteration or improvement to an existing residential structure shall be elevated not less than 1 1/2 feet above the base flood elevation at the site. Modifications to nonresidential structures shall be elevated not less than 1 1/2 feet above the base flood elevation or shall conform with the waterproofing requirements set forth in §
170-82.
B. Any and all fill materials shall:
(1) Extend laterally at least 15 feet beyond the building line from all
points.
(2) Consist of soil or small rock materials only; sanitary landfills
shall not be permitted.
(3) Be compacted and stabilized to provide the necessary permeability
and resistance to erosion, scouring, or settling.
(4) Be no steeper than one vertical to two horizontal, unless substantiated
data justifying steeper slopes are submitted to, and approved by,
the Floodplain Administrator.
(5) Be used to the extent to which they do not adversely affect adjacent
properties.
C. Drainage facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets and provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
Storm drainage facilities shall be in compliance with the terms of
the Londonderry Township Stormwater Management Ordinance.
D. Sanitary sewer facilities. All sanitary sewer facilities and private
package sewer treatment plants, including all pumping stations and
collector systems, shall be designed to minimize or eliminate infiltration
of floodwaters into the systems and discharges from the systems into
the floodwaters. In addition, they should be located and constructed
to minimize or eliminate flood damage and impairment. No part of any
on-site waste disposal system shall be located within the Flood Hazard
District.
E. Water facilities. All water facilities shall be designed to minimize
or eliminate infiltration of floodwaters into the system and be located
and constructed to minimize or eliminate flood damages.
F. Streets. The finished elevation of proposed new streets shall be
equal to or higher than the base flood elevation.
G. Utilities. All utilities, such as gas lines, electrical and telephone
systems, being placed in the Flood Hazard District shall be located,
elevated (where possible) and constructed to minimize the chance of
impairment during a flood.
H. Storage. All materials that are buoyant, flammable, explosive or
in times of loading or unloading could be injurious to human, animal
or plant life, shall be stored above the base flood elevation and/or
floodproofed to the maximum extent possible.
I. Buildings and structures. All buildings and structures shall be designed,
located, and constructed so as to offer the minimum obstruction to
the flow of water and shall be designed to have a minimum effect upon
the flow and height of floodwater. All buildings and structures within
or adjacent to the Flood Hazard District shall make the following
improvements:
(1) Paints or other finishes used at or below the base flood elevation
shall be of water-resistant quality.
(2) Adhesives used at or below the base flood elevation shall be finished
with water-resistant paint or other finishing material.
(3) All wooden components shall be finished with a water-resistant paint
or other finishing material.
(4) Electric water heaters, furnaces, air-conditioning and ventilating
systems, and other electrical equipment or apparatus shall not be
located below the base flood elevation.
(5) Electrical distribution panels shall be at least three feet above
the base flood elevation.
(6) Separate electrical circuits shall serve lower levels and shall be
dropped from above.
J. Anchoring. All structures shall be firmly anchored in accordance
with accepted engineering practices to prevent flotation, collapse
or lateral movement.
K. The accessibility of the tract to emergency vehicles in times of
flooding shall be ensured.
L. The danger of materials being swept onto lands downstream shall be
removed.
M. Uniform Construction Code coordination. The standards and specifications
contained in 34 Pa. Code, Chapters 401 through 405, as amended, and
not limited to the following provisions, shall apply to the above
and other sections and subsections of this article, to the extent
that they are more restrictive and/or supplement the requirements
of this article.
(1) International Building Code (IBC) 2009 or latest edition thereof:
§§ 801, 1202, 1403, 1603, 1605, 1612, 3402 and Appendix
G.
(2) International Residential Code (IRC) 2009 or latest edition thereof:
§§ R104, R105, R109, R323, Appendix E, Section AE101,
and Appendix J.
N. Fully enclosed and partially enclosed space below the lowest floor
(including basement) is prohibited.
Within any identified floodplain area, any new construction or substantial improvements shall be prohibited with the exception of uses permitted by right and special exception in Section
170-77. If a variance is obtained for new construction or substantial improvements in the Identified Floodplain Area in accordance with the criteria in §
170-79, then the following provisions apply:
A. Residential structures.
(1) In AE, A1-30, and AH Zones, any new construction or substantial improvement
shall have the lowest floor (including basement) elevated up to, or
above, the regulatory flood elevation.
(2) In A Zones, where there are no base flood elevations specified on
the FIRM, any new construction or substantial improvement shall have
the lowest floor (including basement) elevated up to, or above, the
regulatory flood elevation determined in accordance with the terms
of this article.
(3) In AO Zones, any new construction or substantial improvement shall
have the lowest floor (including basement) at or above the highest
adjacent grade at least as high as the depth number specified on the
FIRM.
(4) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC) or the latest edition thereof adopted by the
Commonwealth of Pennsylvania, and ASCE 24 and 34 Pa. Code (Chapters
401 through 405, as amended) shall be utilized, where they are more
restrictive.
B. Nonresidential structures.
(1) In AE, A1-30 and AH Zones, any new construction or substantial improvement
of a nonresidential structure shall have the lowest floor (including
basement) elevated up to, or above, the regulatory flood elevation,
or be designed and constructed so that the space enclosed below the
regulatory flood elevation:
(a)
Is floodproofed so that the structure is watertight with walls
substantially impermeable to the passage of water; and
(b)
Has structural components with the capability of resisting hydrostatic
and hydrodynamic loads and effects of buoyancy.
(2) In A Zones, where no base flood elevations are specified on the FIRM,
any new construction or substantial improvement shall have the lowest
floor (including basement) elevated or completely floodproofed up
to, or above, the regulatory flood elevation determined in accordance
with the terms of this article.
(3) In AO Zones, any new construction or substantial improvement shall
have the lowest floor elevated or completely floodproofed above the
highest adjacent grade to at least as high as the depth number specified
on the FIRM.
(4) Any nonresidential structure, or part thereof, made watertight below
the regulatory flood elevation shall be floodproofed in accordance
with the W1 or W2 space classification standards contained in the
publication entitled "Flood-Proofing Regulations" published by the
United States Army Corps of Engineers (June 1972, as amended March
1992) or with some other equivalent standard. All plans and specifications
for such floodproofing shall be accompanied by a statement certified
by a registered professional engineer or architect which states that
the proposed design and methods of construction are in conformance
with the above-referenced standards. There should be a statement submitted
with the permit application and a statement submitted with the as-built
floodproofing certificate prior to the issuance of the certificate
of occupancy.
(5) Any nonresidential structure that will be floodproofed must submit
the following to the Floodplain Administrator along with the nonresidential
floodproofing certificate and prior to the issuance of the certificate
of occupancy:
(a)
An inspection and maintenance plan detailing the annual maintenance
of floodproofed components, ensuring that all components will operate
properly under flood conditions. Components that must be inspected
include, at a minimum:
[1]
Mechanical equipment such as sump pumps and generators;
[2]
Flood shields and closures;
[3]
Walls and wall penetrations; and
[4]
Levees and berms (as applicable).
(b)
A flood emergency operation plan detailing the procedures to
be followed during a flooding event, and must include information
pertaining to how all components will operate properly under all conditions,
including power failures. The design professional must produce the
plan. An adequate plan must include the following:
[1]
An established chain of command and responsibility with leadership
responsibilities clearly defined for all aspects of the plan.
[2]
A procedure for notification of necessary parties when flooding
threatens and flood warnings are issued. Personnel required to be
at the building should have a planned and safe means of ingress and
should have no other emergency response duties during a flood event.
Alternates should be assigned in the event that the primary persons
responsible are unable to complete their assigned duties under the
plan.
[3]
A list of specific duties assigned to ensure that all responsibilities
are addressed expeditiously. The locations of materials necessary
to properly install all floodproofing components must be included
in the list.
[4]
An evacuation plan for all personnel or occupants, those without
duties for the flood emergency as well as those with duties for implementing
the plan. All possible ingress and egress routes must be identified.
(6) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC) or the latest revision thereof as adopted by
the Commonwealth of Pennsylvania, and ASCE 24 and 34 Pa. Code.
C. Space below lowest floor.
(1) Fully enclosed space below the lowest floor (excluding basements)
which will be used solely for the parking of a vehicle, building access,
or incidental storage in an area other than a basement shall be designed
and constructed to allow for the automatic entry and exit of floodwaters
for the purpose of equalizing hydrostatic forces on exterior walls.
The term "fully enclosed space" also includes crawl spaces.
(2) Designs for meeting this requirement must either be certified by
a registered professional engineer or architect, or meet or exceed
the following minimum criteria:
(a)
A minimum of two openings having a net total area of not less
than one square inch for every square foot of enclosed space installed
on two separate walls.
(b)
The bottom of all openings shall be no higher than one foot
above grade.
(c)
Openings may be equipped with screens, louvers, or other coverings
or devices, provided that they permit the automatic entry and exit
of floodwaters.
D. Historic structures. Historic structures undergoing repair or rehabilitation
that would constitute a substantial improvement, as defined in this
article, must comply with all ordinance requirements that do not preclude
the structure's continued designation as an historic structure.
Documentation that a specific ordinance requirement will cause removal
of the structure from the National Register of Historic Places or
the State Inventory of Historic Places must be obtained from the Secretary
of the Interior or the State Historic Preservation Officer. Any exemption
from ordinance requirements will be the minimum necessary to preserve
the historic character and design of the structure.
E. Accessory structures. Structures accessory to a principal building
need not be elevated or floodproofed to remain dry, but shall comply,
at a minimum, with the following requirements:
(1) The structure shall not be designed or used for human habitation,
but shall be limited to the parking of vehicles, or to the storage
of tools, material, and equipment related to the principal use or
activity.
(2) Floor area shall not exceed 200 square feet.
(3) The structure will have a low damage potential.
(4) The structure will be located on the site so as to cause the least
obstruction to the flow of floodwaters.
(5) Power lines, wiring, and outlets will be elevated to the regulatory
flood elevation.
(6) Permanently affixed utility equipment and appliances such as furnaces,
heaters, washers, dryers, etc., are prohibited.
(7) Sanitary facilities are prohibited.
(8) The structure shall be adequately anchored to prevent flotation,
collapse, and lateral movement and shall be designed to automatically
provide for the entry and exit of floodwater for the purpose of equalizing
hydrostatic forces on the walls. Designs for meeting this requirement
must either be certified by a registered professional engineer or
architect, or meet or exceed the following minimum criteria:
(a)
A minimum of two openings having a net total area of not less
than one square inch for every square foot of enclosed space.
(b)
The bottom of all openings shall be no higher than one foot
above grade.
(c)
Openings may be equipped with screens, louvers, etc., or other
coverings or devices, provided that they permit the automatic entry
and exit of floodwaters.
(9) If a variance is granted, a signed declaration of land restriction
(nonconversion agreement) shall be recorded on the property deed prior
to issuance of the certificate of occupancy.
(10)
The storage of hazardous materials in accessory structures is
prohibited.
All subdivision proposals and land development proposals containing
at least 50 lots or at least five acres, whichever is the lesser,
in identified floodplain areas where base flood elevation data are
not available shall be supported by hydrologic and hydraulic engineering
analyses that determine base flood elevations and floodway information.
The analyses shall be prepared by a licensed professional engineer
in a format required by FEMA for a conditional letter of map revision
(CLOMR) and letter of map revision (LOMR). Submittal requirements
and processing fees shall be the responsibility of the applicant.
Within any identified floodplain area, recreational vehicles
shall be prohibited. If a variance is obtained, then recreational
vehicles in Zones A, A1-30, AH and AE must be:
A. On the site for fewer than 180 consecutive days; and
B. Fully licensed and ready for highway use.
For the purpose of and as used in this article, the following
definitions shall apply:
ACCESSORY USE OR STRUCTURE
A use or structure on the same lot with, and of a nature
customarily incidental and subordinate to, the principal use or structure.
BASE FLOOD
A flood which has a one-percent chance of being equaled or
exceeded in any given year (also called the "one-percent-annual-chance
flood").
BASE FLOOD DISCHARGE
The volume of water resulting from a base flood as it passes
a given location within a given time, usually expressed in cubic feet
per second (cfs).
BASE FLOOD ELEVATION (BFE)
The elevation shown on the Flood Insurance Rate Map (FIRM)
for Zones AE, AH, and A1-30 that indicates the water surface elevation
resulting from a flood that has a one-percent or greater chance of
being equaled or exceeded in any given year.
BASEMENT
Any area of the building having its floor below ground level
on all sides.
BUILDING
A combination of materials to form a permanent structure
having walls and a roof. Included shall be all manufactured homes
and trailers to be used for human habitation.
DECLARATION OF LAND RESTRICTION (NONCONVERSION AGREEMENT)
A form signed by the property owner to agree not to convert
or modify, in any manner that is inconsistent with the terms of the
permit and these regulations, certain enclosures below the lowest
floor of elevated buildings and certain accessory structures. The
form requires the owner to record it on the property deed to inform
future owners of the restrictions.
DEVELOPMENT
Any man-made change to improved or unimproved real estate,
including but not limited to the construction, reconstruction, renovation,
repair, expansion, or alteration of buildings or other structures;
the placement of manufactured homes; streets and other paving; utilities;
filling, grading and excavation; mining; dredging; drilling operations;
storage of equipment or materials; and the subdivision of land.
EXISTING MANUFACTURED HOME PARK OR SUBDIVISION
A manufactured home park or subdivision for which the construction
of facilities for servicing the lots on which the manufactured homes
are to be affixed (including, at a minimum, the installation of utilities,
the construction of streets, and either final site grading or the
pouring of concrete pads) is completed before the effective date of
the floodplain management regulations adopted by a community.
EXPANSION TO AN EXISTING MANUFACTURED HOME PARK OR SUBDIVISION
The preparation of additional sites by the construction of
facilities for servicing the lots on which the manufactured homes
are to be affixed (including the installation of utilities, the construction
of streets, and either final site grading or the pouring of concrete
pads).
FLOOD
A temporary inundation of normally dry land areas.
FLOOD INSURANCE RATE MAP (FIRM)
The official map on which the Federal Emergency Management
Agency has delineated both the areas of special flood hazards and
the risk premium zones applicable to the community.
FLOOD INSURANCE STUDY (FIS)
The official report provided by the Federal Emergency Management
Agency that includes flood profiles, the Flood Insurance Rate Map,
the Flood Boundary and Floodway Map, and the water surface elevation
of the base flood.
FLOODPLAIN AREA
A relatively flat or low land area which is subject to partial
or complete inundation from an adjoining or nearby stream, river or
watercourse; and/or any area subject to the unusual and rapid accumulation
of surface waters from any source.
FLOODPROOFING
Any combination of structural and nonstructural additions,
changes, or adjustments to structures which reduce or eliminate flood
damage to real estate or improved real property, water and sanitary
facilities, structures and their contents.
FLOODWAY
The channel of a river or other watercourse and the adjacent
land areas that must be reserved in order to discharge the base flood
without cumulatively increasing the water surface elevation more than
one foot.
HIGHEST ADJACENT GRADE
The highest natural elevation of the ground surface prior
to construction next to the proposed walls of a structure.
HISTORIC STRUCTURES
Any structure that is:
A.
Listed individually in the National Register of Historic Places
(a listing maintained by the Department of the Interior) or preliminarily
determined by the Secretary of the Interior as meeting the requirements
for individual listing on the National Register;
B.
Certified or preliminarily determined by the Secretary of the
Interior as contributing to the historical significance of a registered
historic district or a district preliminarily determined by the Secretary
to qualify as a registered historic district;
C.
Individually listed on a state inventory of historic places
in states which have been approved by the Secretary of the Interior;
or
D.
Individually listed on a local inventory of historic places
in communities with historic preservation that have been certified
either:
(1)
By an approved state program as determined by the Secretary
of the Interior; or
(2)
Directly by the Secretary of the Interior in states without
approved programs.
IDENTIFIED FLOODPLAIN AREA
This term is an umbrella term that includes all of the areas
within which the community has selected to enforce floodplain regulations.
It will always include the area identified as the special flood hazard
area on the Flood Insurance Rate Maps and Flood Insurance Study, but
may include additional areas identified by the community.
LOWEST FLOOR
The lowest floor of the lowest fully enclosed area (including
basement). An unfinished, flood-resistant partially enclosed area,
used solely for parking of vehicles, building access, and incidental
storage, in an area other than a basement area is not considered the
lowest floor of a building, provided that such space is not designed
and built so that the structure is in violation of the applicable
nonelevation design requirements of this article.
MANUFACTURED HOME
A structure, transportable in one or more sections, which
is built on a permanent chassis, and is designed for use with or without
a permanent foundation when attached to the required utilities. The
term includes park trailers, travel trailers, recreational vehicles
and other similar vehicles which are placed on a site for more than
180 consecutive days.
NEW CONSTRUCTION
Structures for which the start of construction commenced
on or after the effective start date of this floodplain management
article, and includes any subsequent improvements to such structures.
Any construction started after September 24, 1984, and before the
effective start date of this floodplain management article is subject
to the ordinance in effect at the time the permit was issued, provided
the start of construction was within 180 days of permit issuance.
NEW MANUFACTURED HOME PARK OR SUBDIVISION
A manufactured home park or subdivision for which the construction
of facilities for servicing the lots on which the manufactured homes
are to be affixed (including, at a minimum, the installation of utilities,
the construction of streets, and either final site grading or the
pouring of concrete pads) is completed on or after the effective date
of floodplain management regulations adopted by a community.
PERSON
An individual, partnership, public or private association
or corporation, firm, trust, estate, municipality, governmental unit,
public utility, or any other legal entity whatsoever, which is recognized
by law as the subject of rights and duties.
POST-FIRM STRUCTURE
A structure for which construction or substantial improvement
occurred after December 31, 1974, or on or after the community's
initial Flood Insurance Rate Map (FIRM) dated September 24, 1984,
whichever is later, and, as such, would be required to be compliant
with the regulations of the National Flood Insurance Program.
PRE-FIRM STRUCTURE
A structure for which construction or substantial improvement
occurred on or before December 31, 1974, or before the community's
initial Flood Insurance Rate Map (FIRM) dated September 24, 1984,
whichever is later, and, as such, would not be required to be compliant
with the regulations of the National Flood Insurance Program.
RECREATIONAL VEHICLE
A vehicle which is:
A.
Built on a single chassis;
B.
Not more than 400 square feet, measured at the largest horizontal
projections;
C.
Designed to be self-propelled or permanently towable by a light-duty
truck;
D.
Not designed for use as a permanent dwelling but as temporary
living quarters for recreational, camping, travel, or seasonal use.
REGULATORY FLOOD ELEVATION
The base flood elevation (BFE) or estimated flood height
as determined using simplified methods plus a freeboard safety factor
of 1 1/2 feet. The freeboard safety factor also applies to utilities
and ductwork.
SPECIAL FLOOD HAZARD AREA (SFHA)
An area in the floodplain subject to a one-percent or greater
chance of flooding in any given year. It is shown on the FIRM as Zone
A, AO, A1-A30, AE, A99, or AH.
START OF CONSTRUCTION
Includes substantial improvement and other proposed new development
and means the date the permit was issued, provided the actual start
of construction, repair, reconstruction, rehabilitation, addition,
placement, or other improvement was within 180 days after the date
of the permit and shall be completed within 12 months after the date
of issuance of the permit unless a time extension is granted, in writing,
by the Floodplain Administrator. The "actual start" means either the
first placement of permanent construction of a structure on a site
such as the pouring of slab or footings, the installation of piles,
the construction of columns, or any work beyond the stage of excavation;
or the placement of a manufactured home on a foundation. Permanent
construction does not include land preparation, such as clearing,
grading, and filling; nor does it include the installation of streets
and walkways; nor does it include excavation for a basement, footings,
piers, or foundations or the erection of temporary forms; nor does
it include the installation on the property of accessory buildings,
such as garages or sheds not occupied as dwelling units or not part
of the main structure. For a substantial improvement, the "actual
start of construction" means the first alteration of any wall, ceiling,
floor, or other structural part of a building, whether or not that
alteration affects the external dimensions of the building.
STRUCTURE
A walled and roofed building, including a gas or liquid storage
tank, that is principally above ground, as well as a manufactured
home.
SUBDIVISION
The division or redivision of a lot, tract, or parcel of
land by any means into two or more lots, tracts, parcels or other
divisions of land, including changes in existing lot lines for the
purpose, whether immediate or future, of lease, partition by the court
for distribution to heirs or devisees, transfer of ownership or building
or lot development; provided, however, that the subdivision by lease
of land for agricultural purposes into parcels of more than 10 acres,
not involving any new street or easement of access or any residential
dwelling, shall be exempted.
SUBSTANTIAL DAMAGE
Damage from any cause sustained by a structure whereby the
cost of restoring the structure to its before-damaged condition would
equal or exceed 50% of the market value of the structure before the
damage occurred.
SUBSTANTIAL IMPROVEMENT
Any reconstruction, rehabilitation, addition, or other improvement
of a structure, of which the cost equals or exceeds 50% of the market
value of the structure before the start of construction of the improvement.
This term includes structures which have incurred substantial damage
regardless of the actual repair work performed. The term does not,
however, include any project for improvement of a structure to correct
existing violations of state or local health, sanitary, or safety
code specifications which have been identified by the local code enforcement
official and which are the minimum necessary to assure safe living
conditions.
UNIFORM CONSTRUCTION CODE (UCC)
The statewide building code adopted by the Pennsylvania General
Assembly in 1999 applicable to new construction in all municipalities,
whether administered by the municipality, a third party or the Department
of Labor and Industry. Applicable to residential and commercial buildings,
the code adopted the International Residential Code (IRC) and the
International Building Code (IBC), by reference, as the construction
standard applicable with the state floodplain construction. For coordination
purposes, references to the above are made specifically to various
sections of the IRC and the IBC.
VARIANCE
A grant of relief by the Zoning Hearing Board from the terms
of a floodplain management regulation.
VIOLATION
The failure of a structure or other development to be fully
compliant with the community's floodplain management regulations.
A structure or other development without the elevation certificate,
other certifications, or other evidence of compliance required in
44 CFR 60.3(b)(5), (c)(4), (c)(10), (d)(3), (e)(2), (e)(4), or (e)(5)
is presumed to be in violation until such time as that documentation
is provided.