Pennants
| ||||||
---|---|---|---|---|---|---|
Registered Boat Length
(feet)
|
Mushroom Anchor
(pounds)
|
Bottom Chain
|
Top Chain
|
Nylon/ Dacron Line
(inches)
|
Chain
(inches)
|
Stainless Steel Wire
(inches)
|
Under 16
|
75
|
5/16-inch galvan-ized
|
1/2
|
5/16
|
1/4
| |
16 to 18
|
100
|
5/16-inch galvan-ized
|
1/2
|
5/16
|
1/4
| |
19 to 22
|
150
|
3/8-inch galvan-ized, 20 feet
|
5/8
|
5/16
|
1/4
| |
23 to 26
|
200
|
3/8-inch galvan-ized, 20 feet
|
5/8
|
5/16
|
1/4
| |
27 to 30
|
250
|
1/2-inch galvan-ized, galvan-ized, 20 feet
|
3/8-inch galvan-ized
|
3/4
|
3/8
|
1/4
|
31 to 34
|
300
|
1/2-inch galvan-ized, 20 feet
|
3/4
|
3/8
|
1/4
| |
35 to 37
|
350
|
1/2-inch galvan-ized, 20 feet
|
3/4
|
3/8
|
1/4
| |
38 to 40
|
400
|
1/2-inch galvan-ized, 30 feet
|
3/4
|
3/8
|
1/4
| |
41 to 50
|
500
|
5/8-inch galvan-ized, 30 feet
|
1/2-inch galvan-ized
|
1 1/2
|
3/8
| |
51 to 60
|
600
|
5/8-inch galvan-ized, 30 feet
|
1 1/2
|
3/8
| ||
61 to 75
|
750
|
3/4-inch galvan-ized, 30 feet
|
1 1/2
|
3/8
| ||
76 to 100
|
1,000
|
3/4-inch galvan-ized, 30 feet
|
1 1/2
|
3/8
|
CAUTION
| |
1.
|
Keep container valves closed when boat is unattended. Close
them immediately in an emergency.
|
2.
|
Be sure all appliance valves are closed before opening container
valve.
|
3.
|
Always apply lit match or other flame to burner before opening
burner valve.
|
4.
|
Close master valve on appliance whenever appliance is not in
use.
|
5.
|
Test system for leakage at least once every two weeks and after
any emergency in accordance with the following procedure. No leakage,
even of a seeping character, is permissible: With appliance valves
closed, with the master shutoff valve on the appliance open and with
one container valve open, note pressure on the gauge. Close container
valve. If the pressure drops, locate leakage by application of liquid
detergent or soapy water solution at all connections. Repeat test
for each container in a multicontainer system.
|
NEVER USE FLAME TO TEST FOR LEAKS
|