With central water and central sewer: T - (W+F+S+I) x 0.40 =
OS
|
With private wells and/or septic: T - (W+F+S+I) x 0.50 = OS
|
Where:
| ||
T
|
=
|
Total land area (acres) inside the boundary lines of the project
parcel.
|
W
|
=
|
Total land area (acres) inside the boundary lines of the project
parcel and within a NYSDEC or USACOE regulated wetland (exclusive
of any buffer area).
|
F
|
=
|
Total land area (acres) inside the boundary lines of the project
parcel and within the 100-year floodplain area where the base elevations
and flood hazard are determined exclusive of any flood area within
a regulated state or federal wetland.
|
S
|
=
|
Total land area (acres) inside the boundary lines of the project
parcel and containing slopes of 15% or greater.
|
I
|
=
|
The total acreage of required public improvements (i.e., roads,
sidewalks, stormwater management facilities, utility easements).
|
OS
|
=
|
Minimum land area (acres) required for open space.
|