The following land subdivision and development
principles, standards and requirements shall be applied by the Township
Engineer, Planning Commission and Board in evaluating plans for proposed
subdivisions and land developments. These principles, standards and
requirements are the minimum provisions required by the Township for
the promotion of public health, safety, and general welfare.
[Amended 11-13-2019 by Ord. No. 320]
A. Single access streets shall not be approved wherever a through street connecting with other surrounding streets is feasible, unless such a connection is impractical or undesirable per the considerations outlined in §
175-29F.
B. Measurement of length. The length of a single access street shall
be measured along the center line of the street beginning at the center
line of the intersecting street and ending at the center of the cul-de-sac
bulb or the point at which a loop street connects back to itself.
C. A single access street, permanently designed as such, shall not exceed 1,000 feet in length, unless an emergency access is provided. Any required emergency access or fire apparatus access road shall be constructed in accordance with Chapter
90 of the Township Code (Fire Prevention).
D. An emergency access may also be required for a single access street that will not exceed 1,000 feet in length, whether permanently designed as such or as part of a phased development, if so required by the International Fire Code. Any required emergency access or fire apparatus access road shall be constructed in accordance with Chapter
90 of the Township Code (Fire Prevention).
E. Radius. Where permitted, a cul-de-sac shall be provided at the closed
end with a paved turnaround having a minimum radius to the outer pavement
edge or curb line of 50 feet with a minimum right-of-way radius of
60 feet.
F. Design and connection. The Board shall consider the existing or proposed
uses of adjoining lands, topography, drainage and other relevant site
characteristics affecting the design of a single access street or
through street. Unless a through street or future extension of a single
access street is impractical or undesirable based on the foregoing
considerations, or is precluded by the Board, which they shall have
the discretion to do, the right-of-way of a single access street shall
extend to the property line of the development tract and a right-of-way
for the same width as the street shall be carried to the property
line in such a way as to permit future extension of the street into
the adjoining tract. The future street extension shall be clearly
identified with signage.
G. Drainage. Drainage of a single access street shall be directed towards the open end of the cul-de-sac or loop end of the street, subject to the other design criteria specified in this chapter. All stormwater management and street drainage shall be in accordance with Chapter
170 of the Township Code (Stormwater Management).
H. Design. The design of single access streets shall be designed to
local or residential street standards, except that the centerline
grade shall not exceed 8% and the grade of the diameter of the turnaround
area shall not exceed 4%.
I. Temporary cul-de-sac. Where streets are temporarily terminated at
a property line or phase line with a temporary vehicular turnaround,
thus forming a cul-de-sac until such time as the street is extended,
all regulations pertaining to single access streets shall apply, except
that the temporary cartway turnaround need not be curbed unless so
directed by the Township Engineer. At such a time that the temporary
cul-de-sac has been extended and is no longer needed for the purposes
of a turnaround, the additional pavement from its radius shall be
removed and the ground restored to a vegetation condition.
[Amended 11-13-2019 by Ord. No. 320]
A. Streets in floodplains. Streets within a subdivision or land development
located entirely or partially within a designated Flood Hazard District
shall be prohibited unless the proposed street is intended to traverse
the floodplain area as part of an approved stream crossing by the
Pennsylvania Department of Environmental Protection or an appropriate
agency.
B. Obstructions. No fences, hedges, freestanding walls, plantings (except
approved street trees), or other obstructions shall be located or
remain within the right-of-way of a street.
C. Curbing is required for all new streets, regardless of roadway functional
classification.
D. Streetlights. Poles and standards for streetlights with appropriate
shielding and underground parkway cable service lines shall be furnished
and installed by the developer, spaced not more than 500 feet apart
and each providing with 0.2 footcandles of illumination. The Township
Engineer shall direct the type and location of streetlights to be
installed within the right-of-way areas.
E. Street trees. Deciduous street trees shall be planted by the developer within general alignment along the edge of the roadway, staggered along both sides, and spaced according to the type of tree. Street tree planting shall be required along all new or existing streets. Such trees must be properly balled and burlapped in accordance with accepted horticultural practice. This requirement is in addition to the landscaping requirements specified in §
175-41 and Chapter
200 of the Township Code (Zoning, Article
XI regarding buffers) for the zoning district in which the property is located.
(1) Size. Tree caliper at time of planting shall be no less than 2.5
inches (one foot above ground level) in both residential and nonresidential
developments.
(2) Approved street trees. The following tree varieties are approved
for use within street rights-of-way:
(a)
Celtis occidentalis (Hackberry).
(b)
Diospyros virginiana (Common Persimmon).
(c)
Quercus imbricaria (Laurel or Shingle Oak).
(d)
Quercus phellos (Willow Oak).
(f)
Tilia cordata (Liftieleaf Linden).
(g)
Ulmus parviflora (Chinese Elm).
(h)
Zelkova serrata (Japanese Zelkova).
(j)
Gleditsia tricanthos inermis shademaster (Shademaster Locust).
(k)
Prunus yedoenis (Yoshino Cherry).
(l)
Ginkgo biloba (Ginko, male only).
(m)
Quercus acutissima (Sawtooth Oak).
(n)
Acer saccharum (Sugar Maple).
F. Screening. An effective buffer screen in compliance with §
175-41 and Chapter
200 of the Township Code (Zoning, Article
XI regarding buffers) shall be required whenever a development abuts a different zoning use or zoning district. For example, where a residential development abuts a commercial or industrial use or district, or where a commercial or industrial development abuts a residential use or district.
G. Fire hydrants. Where a public water system is reasonably accessible or will serve a proposed development, the developer shall install fire hydrants in accordance with Chapter
90 of the Township Code (Fire Prevention). Unless otherwise dictated therein, fire hydrants shall be located within a 600-foot radius of any house or building within the subdivision or land development. Fire hydrants shall each provide the number of gallons of water per minute at the number of pounds per square inch pressure sufficient, in both cases, to meet the minimum fire flow requirements or standards of Chapter
90 of the Township Code (Fire Prevention).
H. Street names and signs. Street name signs shall be installed at the
intersection of each street with another street, whether public or
private, and shall at a minimum comply with the following specifications:
(1) The sign shall be made of extruded aluminum, white in color, with
four-inch reflectorized black letters, shall measure a minimum of
24 inches in length, and shall be equipped with vandal-proof mounting
hardware.
(2) The post on which the sign shall be mounted shall be galvanized steel,
measuring 2.5 inches in outside diameter, and shall be a minimum of
10 feet in length.
(3) The sign shall be installed two feet from the edge of the pavement
or curb, measured from the edge of pavement or face of the curb to
the nearest edge of the sign.
(4) The sign shall be connected to the top of the post, and shall have
an installed minimum height of seven feet measured from ground line
to the bottom of the sign.
(5) Street names shall be approved by the Board and duplication shall be avoided unless as a continuation of an existing street or projection of same. With respect to a cul-de-sac, the developer shall install at each street intersection nearest the bulb of the cul-de-sac a "dead end" or "no outlet" sign, unless a future extension is envisioned in accordance with §
175-29F.
I. Street dedication. The Board may require the dedication of new streets
within any subdivision or land development as a condition to the approval
of a subdivision or land development plan, however, the Board is not
required to accept new subdivision or land development roadways which
are offered for dedication.
J. Private streets. All private streets shall meet the appropriate East
Whiteland Township public street design and construction standards
based on street type as set forth in the applicable ordinances.
K. Addressing. All street names and street numbering shall be reviewed
and approved by the Township in coordination with Chester County Emergency
Services. Proposed street names shall be labeled on the plans and
all street numbering shall be correlated to lot numbers in a table
shown on the plans. All addressing information shall be contained
on the final plan prior to recording.
[Amended 11-13-2019 by Ord. No. 320]
A. Minimum widths. The minimum widths of street rights-of-way, travel
lanes, shoulders, and parking lanes shall not be less than those widths
of an existing street of which a new street is to be a continuation
or the following designated minimum widths, whichever is greater.
Where a development is proposed along an existing roadway, the applicant
shall be required to improve the existing street to the minimum standards
outlined in this chapter.
(1) Street right-of-way. Minimum street right-of-way shall be based on
the roadway functional classification as designated in the Township's
Roadway Functional Classification Map for existing public and private streets, or as designated
by the Township Engineer for new streets not included therein, according
to the following:
Street Type
|
Minimum Right-of-Way Width
(feet)
|
---|
Major arterial
|
120
|
Minor arterial
|
90
|
Major or minor collector
|
70
|
Distributor
|
60
|
Local or residential street (with on-street parking on both
sides)
|
60
|
Local or residential street (without on-street parking)
|
50
|
(2) Travel lanes. The minimum width of each travel lane shall be based
on the roadway functional classification as designated in the Township's
Roadway Functional Classification Map for existing streets, or as designated by the Township
Engineer for new streets not included therein. Travel lane widths
are dependent on the design of curb and/or on-street parking adjacent
to the travel lane, according to the following:
|
Minimum Travel Lane Width (feet)
|
---|
Street Type
|
Curb without On-Street Parking
|
Curb with On-Street Parking
|
No Curb
|
---|
Major or minor arterial
Major or minor collector distributor
|
14
|
11
|
11
|
Local
|
14
|
11
|
10
|
Residential streets
With average daily traffic (ADT) between 1,000 and 2,000 vehicles/day
|
13
|
11
|
11
|
Residential streets
With average daily traffic (ADT) between 400 and 1,000 vehicles/day
|
13
|
10
|
10
|
Residential streets
With average daily traffic (ADT) less than 400 vehicles/day
|
13
|
9
|
9
|
(3) Shoulders, on-street parking lane, on-road bicycle infrastructure.
The minimum width of a shoulder or parking lane shall be based on
the roadway functional classification as designated in the Township's
Roadway Functional Classification Map for existing streets, or as designated by the Township
Engineer for new streets not included therein. Widths are dependent
on the design of on-street parking and on-road bicycle infrastructure
adjacent to the travel lane, according to the following:
(a)
For existing or proposed streets without a curb, either a shoulder,
on-street parking lane, or on-road bicycle infrastructure shall be
provided adjacent to the outside travel lanes.
(b)
Where on-street parking lanes are not provided, parking restriction
signs shall be required and such restrictions shall be noted on the
plan.
(c)
For existing or proposed streets with a curb, a shoulder is not necessary unless needed to accommodate stormwater drainage or if otherwise required by the Township Engineer for a demonstrable purpose. See §
175-41.2 of this chapter for requirements and provisions related to on-road bicycle infrastructure. The width of a shoulder, on-street parking lane, or on-road bicycle infrastructure shall be designed according to the following:
|
Minimum Shoulder, On-Street Parking Lane, On-Road Bicycle Infrastructure
Width (feet)
|
---|
Street Type
|
Shoulder
|
On-Street Parking
|
On-Road Bicycle Infrastructure
|
---|
Major arterial
|
8
|
Not permitted
|
|
Minor arterial
Major or minor collector
|
4
|
8
|
Distributor
Local
With average daily traffic (ADT) more than 2,000
vehicles/day
|
3
|
8
|
Distributor
Local
Residential streets
With average daily traffic (ADT) less than 2,000
vehicles/day
|
2
|
8
|
B. Additional widths. Additional width for street rights-of-way, travel
lanes, shoulders, and on-street parking lanes widths shall be required
if determined necessary by the Township Engineer due to any of the
following factors:
(1) To promote public safety and convenience or to avoid an otherwise
hazardous condition.
(2) To meet PennDOT requirements for state-owned roadways.
(3) To provide on-street parking or on-road bicycle infrastructure.
(4) To provide off-road bicycle infrastructure, pedestrian infrastructure,
or bus stop infrastructure.
(5) To provide for acceptable turning movements and vehicular circulation.
(6) To accommodate stormwater drainage facilities.
(7) To accommodate special topographic conditions or circumstances which
may result in cut-and-fill slopes extending beyond the standard right-of-way
so as to assure safety and accessibility for maintenance, snow removal
and similar needs.
C. Street construction. Construction of all streets and accessory installations
thereto, including but not limited to curbs, shoulders, bicycle infrastructure,
pedestrian infrastructure, and storm drainage structures, shall conform
to the minimum specifications of this chapter.
D. Exception to minimum widths. Short extensions (not exceeding 100 feet) of existing streets with lesser rights-of-way, travel lanes, shoulders, and/or parking lane widths than prescribed by Subsection
A may be permitted at the sole discretion of the Board; provided, however, that no section of the new right-of-way shall be less than 50 feet in width.
E. Improving existing streets. Where a subdivision or land development
abuts or contains an existing street with a right-of-way, travel lanes,
shoulders, parking lanes, and/or alignment which are insufficient
relative to the anticipated traffic demands of the development and/or
does not otherwise comply with the provisions of this chapter, the
Board shall require that the street be modified to comply with the
applicable sections of the East Whiteland Township ordinances.
[Amended 11-13-2019 by Ord. No. 320]
A. Sight distance. The minimum sight distance, measured along an unobstructed
line of sight within the paved area along all sections of the street
surface, with the height of the driver and the object at 3.5 feet
above the pavement surface, shall be provided in accordance with the
American Association of State Highway and Transportation Officials
standards and not less than 200 feet for distributor, local, and residential
streets.
B. Horizontal curves. Whenever street centerlines are deflected in excess
of 5° for local streets, and one degree for all other streets,
connection shall be made by horizontal curves. Horizontal curves shall
have a minimum centerline radius and superelevation in accordance
with the American Association of State Highway and Transportation
Officials standards and not less than 150 feet for local streets with
a posted speed limit of 25 miles per hour.
C. Tangents. Tangents with a maximum difference in bearing of 5º
may intersect at the center line of intersections with cross streets;
otherwise, such intersections shall not be permitted. Reverse curves
on local streets, and horizontal curves on all other streets shall
be separated by tangents of not less than 100 feet. Superelevation
shall be provided as required by the American Association of State
Highway and Transportation Officials design criteria. Sweeping curves
of comparatively long radius shall be required rather than tangents
connecting curves leading in the same direction.
D. Preclusion. A combination of minimum radius horizontal curve and
maximum grade is not permitted.
E. Vertical curves. Vertical curves shall be used in all changes in
gradient of more than 1% and the length at such changes shall be 25
feet for each 1% change in grade or not less than that required for
a 25 mile per hour design speed for all local and residential streets.
All other streets shall be designed and constructed in accordance
with the American Association of State Highway and Transportation
Officials standards.
F. Street grades.
(1) Centerline grades shall not be not less than 1% and shall not exceed
the following:
Street Type
|
Maximum Grade of Centerline
|
---|
Major or minor arterial
|
6%
|
Major collector
|
8%
|
Minor collector
|
9%
|
Distributor
|
|
Local
|
|
Residential streets
|
10%
|
(2) Where the grade of any proposed or modified street at the approach
to an existing or newly created intersection exceeds 2%, a leveling
area shall be provided having a grade not greater than 2% for a distance
of 60 feet. The length of the required leveling area shall be measured
from the nearest edge of pavement or right-of-way line of the intersecting
street, whichever is greater.
(3) The grades between the curbline or edge of pavement and the street
right-of-way line shall not exceed 2%.
(4) Grades beyond the right-of-way line where cut or fill is necessary
shall be at a maximum of three to one.
(5) All streets shall be graded subject to the criteria of this chapter.
All grades shall be shown on the profile and cross section plan submitted
and approved with the final plan.
G. Roadway drainage. All roadway stormwater facilities shall be designed in accordance with PennDOT Publication 13M "Design Manual Part
2 - Highway Design" and PennDOT Publication 584 "Drainage Manual" and shall be consistent with Chapter
170 (Stormwater Management). This includes inlet spacing, pipe capacity, and all other roadway and roadside drainage requirements.
[Amended 11-13-2019 by Ord. No. 320]
A. Right angles. Streets shall be laid out to intersect as nearly as
possible at right angles 90°. No street intersection shall be
created with an angle of less than 75° or more than 105°.
Right-of-way lines shall intersect at 90°, but in no case less
than 75°, and shall be rounded by a tangential are having a minimum
radius of 30 feet.
B. Multiple intersections prohibited. Multiple intersections involving
the junction of more than two streets shall be prohibited. No waiver
for this provision shall be granted unless acceptable proof is provided
by the developer that natural land features, such as steep slopes,
mature healthy trees, wetlands and similar features will be preserved
and public safety will not be affected by allowance of the waiver.
C. Intersections. Intersections of streets, whether public or private,
with major arterial and minor arterial traffic streets shall be located
not less than 1,000 feet apart, measured from centerline to centerline.
D. Opposing streets. Streets entering from the opposite sides of another
street shall either be directly across from each other or offset by
at least 150 feet for major collector, minor collector, distributor,
and local streets and 300 feet on major arterial and minor arterial
streets, measured from center line to center line.
E. Corner radius. Minimum corner radii at street intersections shall
be 30 feet for intersections involving distributor and local streets,
40 feet for all other intersections, or such greater radius as is
suitable to the specific intersection as usually determined by truck
turning movements, and as determined by the Township Engineer. Public
street right-of-way lines shall be parallel to (concentric with) corner
arcs at intersections. If the corner is curbed, then all curbs and
ramps shall comply with minimum ADA requirements.
F. Grade. The intersection area and corresponding approach areas shall be designed with a level grade not to exceed 2% in any direction. Intersection approach areas shall be designed consistent with §
175-32F(2).
G. Street name signs. Street name signs shall be installed at all street intersections prior to the issuance of the first use and occupancy permit by the designated Township Building Official. The design and placement of such signs and the names of the streets shall be subject to the provisions of §
175-30H.
H. Sight distance at street and driveway intersections.
(1) On any lot, no wall, fence or other obstruction shall be erected,
allowed or maintained; and no hedge, tree, shrub or other growth shall
be planted or exist which dangerously obscures the view of approaching
traffic along streets, driveways, or at intersections.
(2) On a corner lot, nothing shall be erected, placed, or allowed to
grow which obscures the view within a clear sight triangle defined
by the following:
(a)
Above the height of 2.5 feet and below the height of 12 feet
measured from the centerline grades of the intersecting streets.
(b)
Within the area bounded by the centerline of intersecting streets
and a line joining points on these centerlines 75 feet from an intersection
of centerlines of such streets.
(3) All driveway and street intersections shall be designed and maintained
in such a manner that a clear view is obtained for vehicles entering
and exiting the intersection, according to the following:
(a)
The measurement and calculation of required sight distances
shall be in accordance with Pennsylvania Code Title 67, Chapter 441,
Access to and Occupancy of Highways by Driveways and Local Roads.
(b)
The PennDOT desirable sight distance requirements are typically
based on the posted speed limit. However, where the speed of traffic
may create a situation with unsafe sight distance, it may be necessary
to verify the 85th percentile speed of traffic at the recommendation
of the Township Engineer. If it is impossible to achieve the desirable
sight distances, then the minimum safe stopping sight distance values
may be used based on the 85th percentile speed of traffic, if necessary,
and subject to review by the Township Engineer.
(c)
If recommended by the Township Engineer, a sight distance profile
plan shall be prepared by a licensed professional engineer in Pennsylvania
to show at least the following for verification of adequate sight
distance and all associated improvements: existing roadway profile
(spot elevations at fifty-foot increments and twenty-five-foot increments
along vertical curves), proposed roadway profile, all sight line profiles
(six inches or more of sight line clearance above the finished grade),
proposed site grading and temporary grading easements.
[Amended 11-13-2019 by Ord. No. 320]
All materials entering into the construction of public and private
streets and/or roads as hereinbefore defined and the method of construction
and installation shall be in strict accordance with the requirements
of PennDOT Publication 408 "Specifications," and PennDOT Bulletin
15 "Approved Construction Materials."
A. Drainage. All drainage and utility structures, including, but not
limited to, manholes, inlets, pipes, water and electric lines, shall
be installed prior to the final grading and paving of the cartway.
B. Grading. Grading shall be completed to the full width of the right-of-way.
The grading of all banks beyond the road right-of-way shall be sloped
not less than 1 1/2 horizontal to one vertical with top of slopes
rounded.
C. Subgrade. The subgrade within the limits of the proposed cartway
shall be shaped to conform to the line, grade and cross-section of
the proposed cartway and shall be thoroughly compacted as per PennDOT
Publication 408. Before placing the base course, the subgrade shall
be dressed with one inch of fine aggregate.
D. Paving. All streets, public or private, shall be paved in accordance
with this section, or as otherwise specified by the Township regulations,
and when all required improvements have been properly installed.
(1) Subgrade. Whenever possible, the subgrade shall be in cut or undisturbed
subsoil. In no case shall the subgrade consist of filled or undisturbed
topsoil or frozen soils. All deleterious material such as tree roots,
leaves, branches, trash, stones exceeding six inches in diameter and
miscellaneous construction debris shall be removed from the subgrade.
Compaction shall be accomplished by a sheep's-foot, smooth-wheel or
rubber-tired roller, as directed by the Township Engineer. The subgrade
shall be compacted tight and dry and shall not be soft and spongy
when check rolled. Compaction of the subgrade shall extend the full
width of the cartway, including the width to be occupied by shoulders
where applicable. The required road crown shall be built into the
shaped subgrade. No unsuitable material is to be used in any portion
of the roadway construction. Remove any subgrade that cannot be properly
compacted and that is unsuitable material. Undercutting and/or subgrade
stabilization may be required. The subgrade must be approved by a
Township representative prior to placement of subbase. If directed
by the Township Engineer, soil testing or review by a qualified third
party geotechnical professional engineer with experience in road subgrade
remediation shall be required.
(2) Base course. The base course shall be constructed of:
(a)
Coarse material: The coarse material shall be No. 2A, or better
stone, compacted to a depth of no less than six inches, meeting the
requirements of PennDOT Publication 408, Section 703.2 and Table C.
(b)
Superpave asphalt mixture design: WMA base course, PG 64-22,
3.0 to 10.0 million ESALs, 25.0 mm mix, five-inch depth in accordance
with PennDOT Publication 408, Section 409.
(c)
All streets shall be laid out and the base course installed
subsequent to the commencement of construction of any structure, building
or facility.
(3) Binder course. A Superpave asphalt mixture design, WMA binder course,
PG 64-22, 3.0 to 10.0 million ESALs, 25.0 mm mix, three-inch depth
meeting the requirements of PennDOT Publication 408, Section 409,
latest edition, shall be applied over the base course. In no case
shall the binder course be applied over a frozen, saturated or excessively
dirt-laden base course. The binder course shall be applied only when
the temperature is at least 45° F. and rising.
(4) Wearing course. After proper cleaning, repairing and preparation
of the binder course as directed by the Township Engineer, a Superpave
asphalt mixture design, WMA wearing course, PG 64-22, 3.0 to 10.0
million ESALs, 9.5 mm mix, one and five-tenths-inch depth, SRL-H shall
be placed over the binder course. The wearing course shall be applied
only when the temperature is at least 45° F. and rising.
(5) The wearing course shall be applied with a paving machine of sufficient
width to create only one center seam (e.g., a thirty-two-foot-wide
cartway shall be paved with a minimum sixteen-foot-wide paver). The
wearing course shall be compacted with an eight-to-ten ton vibratory
roller.
(6) After application of the wearing course, all curb, inlet, manhole,
etc., joints shall be sealed with PG 64-22 joint seal, applied in
neat lines with a minimum width of six inches in accordance with PennDOT
Publication 408, Section 702.
(7) All Township streets shall have a crown with a cross slope of 2%,
sloping away from the centerline, unless otherwise directed by the
Township Engineer.
All materials entering into the construction
of curbs and/or gutters and the method of construction and installation
shall be in accordance with PADOT Publication 408, as amended. Cement
concrete shall comply with PADOT Class AA cement concrete specifications
and is the minimum required in the construction of both curbs and
sidewalks in the Township.
A. Curb types. Vertical curbs shall be required on all
streets. (See Appendix V.)
[Amended 11-13-2019 by Ord. No. 320]
A. Alleys. Alleys may be permitted in residential developments along
the rear of the property to provide an additional means of circulation
and access.
B. Driveways. Driveways intersecting with street rights-of-way shall
be subject to the following requirements:
(1) Private driveways in residential developments shall be located at
least 60 feet from the point of intersection of the nearest street
right-of-way lines and at least 10 feet from a property line.
(2) Private driveways in all other developments shall be located at least
100 feet from the point of intersection of the nearest street right-of-way
lines and at least 20 feet from a property line.
(3) Where driveways are used jointly by more than one property owner,
they may straddle the property line. The appropriate easement restrictions
shall be noted on the final plan, and cross easements for each lot
shall be recorded.
(4) Construction.
(a)
Grades and paving. In order to provide a safe and convenient
means of access, grades on private driveways shall not exceed 4% for
the first 20 feet from the curbline and for the balance shall not
exceed 10%. Driveways shall be paved for their entire length.
(b)
Material. Residential driveways shall be constructed with the
following pavement section: 1.5 inches of SAMD wearing course over
four inches SAMD base course over six inches subbase No. 2A. Commercial
driveways shall be constructed with the following pavement section:
1.5 inches of SAMD wearing course over 2.5 inches SAMD binder course
over six inches SAMD base course over six inches subbase No. 2A.
(c)
Minimum radius. In order to provide safe and convenient ingress and egress, private residence driveway entrances shall be rounded at a minimum radius of five feet or shall have a flare constructed at the point of intersection with the cartway edge (curbline) that is equivalent to this radius. The corner radii for all other driveways shall be in accordance with §
175-33E.
(d)
Minimum width. The minimum width for private residence driveways
shall be 10 feet, unless additional width is required to accommodate
the traffic anticipated.
(e)
Minimum length. The minimum length for private residence driveways
shall be 20 feet as measured from the roadway edge, if no sidewalk
is present. If sidewalk is present, the driveway length shall be measured
20 feet from the nearest sidewalk edge.
(f)
Sight distance. Sight distance shall be provided in accordance with §
175-33.
[Added 11-9-2015 by Ord.
No. 273-2015; 6-21-2021 by Ord. No. 338-2021]
The design guidelines for the GVR Great Valley Revitalization
Overlay District shall be in accordance with the GVR Great Valley
Revitalization Overlay District Design Guidelines set forth in Appendix
VI.
[Added 11-13-2019 by Ord.
No. 320]
A. General requirements.
(1)
Sidewalks, verge areas, and curbs shall be installed along both
sides of all existing and proposed public and private streets in accordance
with the design standards set forth in this chapter as part of a proposed
subdivision or land development.
(a)
Sidewalks, verge areas, and curbs shall be installed along common
driveways and common parking areas in order to connect buildings,
parking areas, common spaces, and pedestrian infrastructure along
adjacent streets.
(b)
Sidewalks shall be installed to connect streets and/or driveways
to the primary entrances of buildings.
(c)
Installation of sidewalks and curbs shall be in accordance with
minimum construction standards in this chapter.
(2)
Paths, multi-use trails, shared lanes, striped shoulders, or
bicycle lanes shall be installed or improved in accordance with the
design standards set forth in this chapter whenever a subdivision
or land development contains or abuts any bicycle infrastructure and/or
pedestrian infrastructure shown on the East Whiteland Township Multimodal
Transportation Map. The improvements shall be designed to the specific site
conditions and constraints of the property provided that:
(a)
The general alignment and connectivity of the proposed improvements
are consistent with the facilities shown on the Multimodal Transportation
Map.
(b)
For improvements to existing pedestrian infrastructure, points
at which a sidewalk, path, or multi-use trail enters and exits the
tract shall remain unchanged.
(c)
Any proposed alteration will not diminish the design and function
of the existing or proposed improvements.
(3)
Verge area.
(a)
A verge area shall be provided between the curb or edge of street
and any off-road pedestrian infrastructure or bicycle infrastructure.
(b)
Verge areas between pedestrian infrastructure and/or bicycle
infrastructure and the curb may contain street lights, trees, benches,
trash cans, mailboxes, or newspaper boxes. No obstacle in the verge
area may reduce the required width of any pedestrian infrastructure
or bicycle infrastructure, nor shall any object obstruct access to
bus stop infrastructure or prevent access to the front, side, or rear
door for the purposes of loading and unloading.
(c)
Verge areas shall be maintained as a grass strip between the
pedestrian infrastructure and curb. If grass is determined to be impractical
by the Township Engineer, then brick pavers, landscaped vegetation,
or similar surface may be used. If a grass strip is not utilized,
a wider sidewalk may be necessary in place of a verge area to create
a safe pedestrian environment.
(d)
Verge areas may be utilized for stormwater management in accordance with Chapter
170 of the Township Code (Stormwater Management).
(e)
Portions of verge areas may be converted to concrete in areas
designated for curbside pick-up/drop-off or for loading pads associated
with designated bus stops on fixed route public transit services.
(4)
Bicycle infrastructure. All bicycle infrastructure shall be
designed and constructed in accordance with the American Association
of State Highway and Transportation Officials (AASHTO) Guide for the
Development of Bicycle Facilities - 4th Edition, 2012.
(5)
Barriers. A safety barrier may be required adjacent to a sidewalk,
path, or multi-use trail to protect users from steep slopes or other
hazards upon recommendation by the Township Engineer. For the purposes
of this section, a steep slope shall be considered any surface with
greater than 6:1 slope.
(6)
The Board of Supervisors may require, as a condition of final
plan approval, the guarantee of public access and improvement of sidewalks,
paths, and multi-use trails when the site is traversed by or abuts
an existing sidewalk, path, or multi-use trail or when such infrastructure
is proposed in an adopted open space or trail plan of Chester County,
East Whiteland Township, or an adjacent municipality.
B. Sidewalks.
(1)
Minimum design standards.
(a)
Sidewalks shall be a minimum of five feet wide. However, wider
sidewalks may be required if determined necessary by the Township
Engineer for accessibility or pedestrian safety purposes.
(b)
Verge areas along a sidewalk shall be a minimum of four feet
wide.
(2)
Minimum construction standards.
(a)
All sidewalks located at street intersections shall be designated
and constructed in accordance with the Americans with Disabilities
Act of 1990, 42 U.S.C. § 12101 et seq. If determined necessary
by the Township Engineer for accessibility or pedestrian safety purposes,
additional curb ramps may be required.
(b)
Sidewalks shall be constructed of concrete having a minimum
twenty-eight-day strength of 3,500 psi.
(c)
The sidewalk shall be constructed on a minimum six-inch depth
of AASHTO No. 57 (PennDOT 2B) coarse aggregate, and shall have a minimum
width of five feet and a thickness of four inches, except at driveway
crossings, where the sidewalk thickness shall be increased to six
inches and reinforced with six-by-six-inch wire mesh.
(d)
Where a sidewalk abuts the curb, a building, a wall or other
permanent structure, a remolded expansion joint 0.5 inch in thickness
shall be placed between the curb and the sidewalk for the full length
of such permanent structure.
(e)
Sidewalks shall be constructed in separate slabs 24 feet or
30 feet in length, except for closures, and the slab between expansion
joints shall be divided into blocks five feet in length by scoring
transversely.
(f)
All sidewalks shall receive a broom finish.
C. Crosswalks.
(1)
General provisions.
(a)
Crosswalks shall be clearly delineated at all intersections.
(2)
Minimum design standards.
(a)
The minimum width of crosswalks shall match the width of the
largest contributing sidewalk, path, multi-use trail, or striped shoulder.
However, in no case shall a crosswalk width be less than six feet.
(b)
Crosswalks shall be placed in a safe location approved by the
Township Engineer or Traffic Engineer as near as possible to the intersection
and on the opposite side of the stop bar for the associated approach.
(c)
Crosswalks and their transition to adjacent sidewalks, paths,
or multi-use trails shall be designed to facilitate access and use
by persons that are physically disabled. Crosswalks shall be designated
and constructed in accordance with the Americans with Disabilities
Act of 1990, 42 U.S.C. § 12101 et seq.
(d)
Countdown pedestrian signalization and pushbuttons shall be
provided at intersections where traffic signals exist or are proposed,
in accordance with East Whiteland Township's Technical Specifications
for Traffic Control Signalization.
(e)
Optional design considerations. Traffic calming or other pedestrian
safety measures may be required at crosswalk locations if determined
to be necessary by the Township Engineer or Traffic Engineer. The
design of such measures shall be approved by the Township Engineer
or Traffic Engineer.
(3)
Minimum construction standards.
(a)
Crosswalks shall be delineated by two parallel six-inch-wide
white lines. For locations where greater pedestrian activity exists
or is anticipated, a continental crosswalk, delineated by twenty-four-inch
wide perpendicular lines, shall be required.
(b)
Reflective thermoplastic pavement markings shall be utilized
for all marked crosswalks where sidewalks, paths, or multi-use trails
intersect with roads.
D. Paths.
(1)
General provisions.
(a)
When existing developed parcels adjacent to a proposed subdivision
or land development allow for dedicated access through a defined area
for the purpose of connecting to an existing or proposed public use
path, a connection shall be constructed and continued through a dedicated
access way through the proposed subdivision or development.
(b)
All paths shall be constructed before occupancy of residences
and other buildings adjoining the accessible path.
(c)
All paths shall provide adequate access for use by the general
public.
(d)
All shall be protected by a permanent access easement on the
properties on which they are located. The width of the protected area
in which the path is located shall be a minimum of five feet on either
side of the path. The Township Solicitor shall draft any necessary
easement agreements.
(e)
No paths shall be designed with the intent to accommodate motorized
vehicles except for emergency or maintenance access.
(f)
The path should be laid out in such a manner that facility users
are visible to other facility users and vehicles on intersecting roads.
Sharp curves and excessive grade change should also be avoided.
(2)
Minimum design standards. The minimum width for accessible paths
shall be six feet.
(a)
If necessary due to the connectivity or anticipated use of the
infrastructure, wider paths or multi-use trails shall be constructed.
(b)
Verge areas along a path shall be a minimum of four feet wide.
(3)
Minimum construction standards. All paths shall be bituminous
pavement and constructed in accordance with the following standards:
(a)
Superpave asphalt mixture design, WMA wearing course, PG 64-22,
less than 0.3 million ESALS, 9.5 mm mix, one-half-inch depth, SRL-L.
(b)
Superpave asphalt mixture design, WMA base course, PG 64-22,
less than 0.3 million ESALS, 25 mm mix, three-inch depth.
(c)
Four inches of PennDOT 2A stone.
(d)
Where the edge of the paths is above surrounding grade, bituminous
pavement shall be feathered.
E. Multi-use trails.
(1)
General provisions.
(a)
When existing developed parcels adjacent to a proposed subdivision
or land development allow for dedicated access through a defined area
for the purpose of connecting to an existing or proposed public use
multi-use trail, a connection shall be constructed and continued through
a dedicated access way through the proposed development.
(b)
All multi-use trails shall be constructed before occupancy of
residences and other buildings adjoining the multi-use trail.
(c)
When multi-use trails are intended for public use, they shall
be protected by a permanent access easement on the properties on which
they are located. The width of the protected area in which the shared
use path or accessible trail is located shall be a minimum of 20 feet.
The Township Solicitor shall draft any necessary easement agreements.
The land area permanently designated for multi-use trails for public
use may be credited toward any open space requirement as described
in the Township Code of Ordinances.
(d)
Multi-use trails shall have adequate access for use by all the
general public.
(e)
Landscaping, fencing, or other barriers shall be used to delineate
the route of the multi-use trail and screen surrounding properties
from users.
(f)
No multi-use trail shall be designed with the intent to accommodate
motorized vehicles except for emergency or maintenance access.
(g)
The multi-use trail should be laid out in such a manner that
facility users are visible to other facility users and vehicles on
intersecting roads. Sharp curves and excessive grade change should
also be avoided.
(2)
Minimum design standards.
(a)
Width.
[1] Minimum width for multi-use trails shall be eight
feet. If such trails are intended to, or otherwise capable of, providing
regional connections to other multi-use trails, then the minimum width
for such multi-use trails shall be 10 feet to 12 feet.
[2] A two-foot-wide shoulder area shall be provided
on each side of the multi-use trail. The shoulder area for the multi-use
trail may be grass, crushed stone, or bituminous pavement, but must
be level and kept clear of vertical elements or obstructions.
[3] Verge areas between a curb or street edge and a
multi-use trail shall be a minimum of five feet.
(3)
Minimum construction standards.
(a)
All multi-use trails shall be bituminous pavement and constructed
in accordance with the following standards.
[1] Superpave asphalt mixture design, WMA wearing course,
PG 64-22, less than 0.3 million ESALS, 9.5 mm mix, one-half-inch depth,
SRL-L.
[2] Superpave asphalt mixture design, WMA base course,
PG 64-22, less than 0.3 million ESALS, 25 mm mix, three-inch depth.
[3] Four inches of PennDOT 2A stone.
[4] Where the edge of the multi-use trail is above
surrounding grade, bituminous pavement shall be feathered.
F. Bicycle lane.
(1)
Minimum design standards.
(a)
Width.
[1] The minimum width of a bicycle lane shall be five
feet. In cases where on-street parking is present, the minimum width
of a bicycle lane shall be six feet.
(b)
Optional design considerations.
[1] Green-colored bituminous pavement in bicycle lanes
may be required in situations where increased visibility is needed,
as determined by the Township Engineer or Traffic Engineer. The green-colored
pavement may be installed for the entire length of the bicycle lane
or for only a portion (or portions) of the bicycle lane.
(2)
Minimum construction standards.
(a)
The edge of the travel lane adjacent to a bicycle lane shall
be striped by a six-inch reflective thermoplastic solid white line.
[1] A dashed white line may be used to carry bicycle
lanes through intersections, turning lanes, and across driveways.
[2] When a parking lane is present, the outside edge
of the bicycle lane shall be striped with a four-inch-wide solid white
line.
(b)
Bicycle lane symbol and arrow markings (MUTCD 9C-3) shall be
used to define the bike lane and designate that portion of the street
for preferential use by bicyclists. Bicycle lane symbol and arrow
markings shall be placed within a bicycle lane at the beginning of
each block. Bicycle lane symbols and arrow markings shall be placed
within a bicycle lane approximately every 500 feet.
[1] Bicycle lane symbols or arrow markings shall not
be placed within an intersection, turning lane, driveway access, or
any such location that the symbol or arrow would be within a motor
vehicle tread path.
(c)
Bike lane signs (MUTCD R3-17) shall be installed at the beginning
of every block adjacent to the bicycle lane. Additional signs may
be spaced evenly on blocks that are longer than 1,000 linear feet.
(d)
The installation of green pavement shall follow PennDOT Construction
Specifications, Publication 408, Section 962 and MUTCD guidelines.
Before installation, the surface must be clean and free from all loose
material, dirt, grease, and oil. The daytime chromaticity coordinates
for the color used for green-colored pavement shall be as follows:
|
X
|
Y
|
---|
1
|
0.230
|
0.754
|
2
|
0.266
|
0.500
|
3
|
0.367
|
0.5000
|
4
|
0.444
|
0.555
|
(e)
The daytime luminance factor (Y) shall be at least 7, but no
more than 35.
(f)
The nighttime chromaticity coordinates for the color used for
green colored pavement shall be as follows:
|
X
|
Y
|
---|
1
|
0.230
|
0.754
|
2
|
0.336
|
0.540
|
3
|
0.450
|
0.500
|
4
|
0.479
|
0.520
|
G. Shared lane.
(1)
Minimum design standards.
(a)
Shared lane marker symbols (MUTCD 9C-9) shall be placed within
street travel lanes as follows:
[1] On streets with a speed limit of 25 mph or slower,
shared lane marker symbols shall be placed in the center of the travel
lane.
[2] On streets with a speed limit higher than 25 mph:
[a] Shared lane marker symbols shall be placed a minimum
of 11 feet from the curb face.
[b] On streets with on-street parking lanes, shared
lane marker symbols shall be placed within the travel lane three feet
from the inside edge of the parking lane.
[c] Shared lane marker symbols shall not be placed
on roads where the speed limit is higher than 35 mph.
(2)
Minimum construction standards.
(a)
Shared lane marker symbols (MUTCD 9C-9) shall be applied to
the street via high-visibility reflective white thermoplastic.
(b)
Shared lane marker symbols (MUTCD 9C-9) shall be placed at the
beginning and end of each block.
(c)
Shared lane marker symbols (MUTCD 9C-9) shall be placed evenly
at a maximum distance of 500 feet.
(d)
"Bicycle May Use Full Lane" signs (MUTCD R4-11) may be posted.
H. Striped shoulders with buffers.
(1)
Minimum design standards.
(a)
Width.
[1] The minimum width of a striped shoulder shall be
five feet.
[2] The minimum width of a striped buffer shall be
two feet.
[3] If directed by the Township Engineer or Traffic
Engineer due to safety or accessibility concerns, a wider striped
shoulder or buffer area shall be provided.
(b)
Optional design considerations.
[1] If directed by the Township Engineer or Traffic
Engineer due to safety or accessibility concerns, the following optional
design treatments shall be required:
[a] Bicycle route and or other wayfinding signage.
[b] Green-colored bituminous pavement to increase visibility.
(2)
Minimum construction standards.
(a)
Paved shoulders shall be delineated from the travel lane by
a high-visibility, reflective, solid, white line measuring a minimum
of six inches in width.
(b)
The buffer shall consist of two parallel white lines each measuring
four inches in width. The buffer area may contain optional crosshatch
markings.
(c)
If present, bicycle route guide sign (MUTCD D11-1c) shall be
placed alongside the street, unobstructed from motor vehicle operators'
view.
I. Designated school bus and fixed route bus boarding and alighting
areas.
(1)
General provisions.
(a)
In the case of a residential subdivision or land development,
the plan shall provide for adequate school bus stop facilities, including
bus shelters and safe gathering areas for students. Upon request of
the Township, such facilities shall be reviewed by the Great Valley
School District.
(b)
When a proposed subdivision or land development abuts an existing
designated stop along fixed route public transit service, a level
loading pad shall be installed in coordination with SEPTA or the appropriate
transit provider.
(c)
When a proposed subdivision or land development is located within
500 of an existing designated stop along fixed route public transit
service, SEPTA or the appropriate transit provider shall be notified.
(d)
A level loading pad shall be provided at a minimum where the
front doors of a fixed route bus service open to receive and discharge
passengers at a designated bus stop. A second loading pad located
at the rear door of the bus may be required.
(e)
The level loading pad must be connected via an ADA accessible
route to adjacent pedestrian infrastructure, such as a sidewalk, path,
or multi-use trail.
(f)
The location and design of the loading pad shall be coordinated
with SEPTA or the appropriate transit provider and approved by the
Township Engineer or Traffic Engineer.
(g)
Boarding and alighting areas for fixed route bus stops shall
be designed and constructed in accordance with the Section 810 of
the United States Department of Transportation's ADA Standards for
Transportation Facilities, 2006 and SEPTA Bus Stop Design Guidelines,
2012.
(2)
Minimum design standards.
(a)
Dimensions.
[1] The minimum clear width of five feet shall be provided
for the loading pad, measured parallel to the roadway.
[2] The minimum clear length of eight feet shall be
provided for the loading pad, measured perpendicular to the curb or
roadway edge.
[3] If directed by the Township Engineer or Traffic
Engineer due to safety or accessibility concerns, a wider loading
pad or separate bus waiting area shall be provided.
(b)
Slope.
[1] Parallel to the roadway, the slope of the loading
pad shall be the same as the roadway, to the maximum extent practicable.
Perpendicular to the roadway, the slope of the loading pad shall not
be steeper than 1:48.
(3)
Minimum construction standards.
(a)
Bus stop boarding and alighting areas shall have a firm, stable,
and slip-resistant surface, preferably concrete built consistent with
the minimum construction standards for sidewalks contained in this
chapter or asphalt consistent with the minimum construction standards
for paths and multi-use trails contained in this chapter.