Title (Points)
|
Severe (5)
|
Moderate (2)
|
Minor (1)
|
None (0)
|
---|---|---|---|---|
Ceiling -Deteriorated/missing ceiling plaster/drywall/sheetrock
|
X
| |||
Ceiling-Deteriorated/missing tile(s)/panel(s)
|
X
| |||
Ceiling-Improper ceiling covering
|
X
| |||
Ceiling-Interior missing/deteriorated/peeling paint
|
X
| |||
Cellar Hatch-Deteriorated cellar hatch walls
|
X
| |||
Cellar Hatch-Deteriorated/missing cellar hatch step(s)
|
X
| |||
Cellar Hatch-Deteriorated/missing/improper cover
|
X
| |||
Chimney-Deteriorated
|
X
| |||
Chimney-Deteriorated/missing clean-out cover
|
X
| |||
Chimney-Deteriorated/missing mortar
|
X
| |||
Chimney-Improperly installed
|
X
| |||
Chimney-Missing/defective cap
|
X
| |||
Doors - frame(s) deteriorated
| ||||
Doors - not weather-tight
|
X
| |||
Doors-window pane(s) broken/missing
|
X
| |||
Doors-Broken/missing storm door glass/pane(s)
|
X
| |||
Doors - Deteriorated storm door(s)
|
X
| |||
Doors-Deteriorated/missing hinge(s)
|
X
| |||
Doors-Deteriorated/missing knob/latch
|
X
| |||
Doors-Deteriorated/missing lock(s)
|
X
| |||
Doors-Deteriorated/missing storm door/patio door screen
|
X
| |||
Doors-Entry door(s) not smoke/draft tight
|
X
| |||
Doors-Improper lock/latch
|
X
| |||
Doors-Lack of a tight-fitting/latch-able bathroom door
|
X
| |||
Doors-Missing/deteriorated
|
X
| |||
Electrical-Antiquated electrical system
|
X
| |||
Electrical-Condition of the electrical system is questionable
|
X
| |||
Electrical-Deteriorated electrical system component(s)
| ||||
Electrical-Deteriorated/improper outdoor electrical device(s)
|
X
| |||
Electrical-Deteriorated/improperly used extension cord(s)
|
X
| |||
Electrical-Deteriorated/inoperable electrical receptacle(s)
|
X
| |||
Electrical-Deteriorated/inoperable fixture(s)
|
X
| |||
Electrical-Deteriorated/inoperable/improperly installed switch(s)
|
X
| |||
Electrical-Deteriorated/loose electric service entrance mast
|
X
| |||
Electrical-Deteriorated/missing electric service entrance wire(s)
protective covering
|
X
| |||
Electrical-Exposed electrical wiring
|
X
| |||
Electrical-Hazardous electrical fixture(s)-Metal pull chain
|
X
| |||
Electrical-Improper/deteriorated meter socket/enclosure
|
X
| |||
Electrical-Improper/missing electrical service grounding
|
X
| |||
Electrical-Improperly installed wiring
|
X
| |||
Electrical-Improperly installed electrical receptacle(s)
|
X
| |||
Electrical-Improperly installed fixture(s)
|
X
| |||
Electrical-Improperly installed/unapproved wiring
|
X
| |||
Electrical-Improperly located electrical service/entrance
|
X
| |||
Electrical-Inadequate number of receptacle(s)/fixture(s)
|
X
| |||
Electrical-Lack of electric service
|
X
| |||
Electrical-Lack of water meter jump wire
|
X
| |||
Electrical-Lack of/improper hallway illumination
|
X
| |||
Electrical-Missing/deteriorated coverplate(s)
|
X
| |||
Electrical-Missing/deteriorated/imp roper service panel cover
|
X
| |||
Electrical-Missing/improper service panel knockout plug(s)
|
X
| |||
Electrical-Missing/improper/deteriorated electrical junction
box cover(s)
|
X
| |||
Electrical-Missing/improper/deteriorated electrical service
entrance wiring
|
X
| |||
Electrical-Over-fused electrical system
|
X
| |||
Electrical-Tree(s)/vegetation interfering/encroaching upon electric
service entrance
|
X
| |||
Exterior Walls-not weather-tight
|
X
| |||
Exterior Walls-Deteriorated/missing exterior block/brick/stucco/stone
|
X
| |||
Exterior Walls-Deteriorated/missing exterior wall covering
|
X
| |||
Exterior Walls-inadequate weather protection
|
X
| |||
Exterior Walls-structural deterioration
|
X
| |||
Exterior Walls-Structurally unsound block/brick/stone/poured
concrete wall
|
X
| |||
Exterior Walls-Window/building trim-inadequate weather protection
|
X
| |||
Fire Code-Bars/grates/locks on an emergency escape
|
X
| |||
Fire Code-Deteriorated/improperly maintained fire escape(s)
|
X
| |||
Fire Code-Deteriorated/inoperable alarm system
|
X
| |||
Fire Code-Fire door(s) missing/deteriorated/inoperable/blocked
open
|
X
| |||
Fire Code-Fire escape obstructed/blocked
|
X
| |||
Fire Code-Fire exit(s)/stairway(s) obstructed
|
X
| |||
Fire Code-Improper storage of combustible material(s)
|
X
| |||
Fire Code-Improper storage of flammable liquid(s)
|
X
| |||
Fire Code-Improper use of portable unvented heating device/appliance
|
X
| |||
Fire Code-Improper utility room(s)/area(s) storage
|
X
| |||
Fire Code-Improperly located fire extinguisher(s)
|
X
| |||
Fire Code-Inadequate exiting above 2nd floor
| ||||
Fire Code-Lack of 1-hour fire resistive door(s)
| ||||
Fire Code-Lack of 1-hour fire resistive separation
| ||||
Fire Code-Lack of heavy smoke detection in a mixed-use occupancy
| ||||
Fire Code-Lack of required fire alarm system
|
X
| |||
Fire Code-Lack of/improper emergency egress window
|
X
| |||
Fire Code-Lack of/improper illumination of exit signage
|
X
| |||
Fire Code-Lack of/improper/inoperable door closer
|
X
| |||
Fire Code-Lack of/inoperable backup exit lighting
|
X
| |||
Fire Code-Missing/improper building identification
|
X
| |||
Fire Code-Missing/improper separation between dwelling/garage
| ||||
Fire Code-Missing/improper/unapproved fire extinguisher(s)
| ||||
Fire Code-Missing/inoperable smoke detector(s)
|
X
| |||
Fire Code-Outdated fire extinguisher(s)
| ||||
Fire Code-Unprotected dwelling/sleeping room exit
| ||||
Fire Code-Unprotected shared exit below 3rd floor
| ||||
Floors-Deteriorated foundation/floor-Engineer required
|
X
| |||
Floors-Deteriorated/defective subfloor
|
X
| |||
Floors-Deteriorated/improperly sized floor joist(s)
| ||||
Floors-Deteriorated/missing floor covering(s)
|
X
| |||
Floors-Deteriorated/missing/inadequate floor support(s)
|
X
| |||
Floors-Improperly installed floor covering(s)-Trip hazard
| ||||
Foundation-mortar cracked/missing
|
X
| |||
Foundation-Deteriorated building/structure foundation
|
X
| |||
Foundation-Structural failure of the building/structure foundation
|
X
| |||
General/Health-Deteriorated accessory structure(s)
|
X
| |||
General/Health-Deteriorated fence(s)
|
X
| |||
General/Health-Deteriorated flatwork/concrete/slab(s)
|
X
| |||
General/Health-Deteriorated private sidewalk(s)
|
X
| |||
General/Health-Deteriorated/leaning/failing retaining structure
(s)/wall(s)
|
X
| |||
General/Health-Deteriorated/missing cabinet drawer(s)
|
X
| |||
General/Health-Deteriorated/missing cabinet(s)
|
X
| |||
General/Health-Deteriorated/missing countertop material
|
X
| |||
General/Health-Evidence of wood boring insects
|
X
| |||
General/Health-Excessive accumulation of trash/debris
|
X
| |||
General/Health-Illegal increase of occupancy
| ||||
General/Health-Illegally occupying a tagged building(s)/unit(s)
|
X
| |||
General/Health-Improper construction/repair(s)
| ||||
General/Health-Improper garbage storage/removal
|
X
| |||
General/Health-Improper grading/drainage
| ||||
General/Health-Improper maintenance
| ||||
General/Health-Inoperable/unsanitary/hazardous swimming pool(s)
|
X
| |||
General/Health-Insect/vermin/rodent infestation
|
X
| |||
General/Health-Interior moisture problem
|
X
| |||
General/Health-Lack of required light and ventilation
|
X
| |||
General/Health-Lack of required room/space
|
X
| |||
General/Health-Mold/mildew in a dwelling(s) unit(s)
|
X
| |||
General/Health-Raw sewage/waste water-cellar floor(s)
|
X
| |||
General/Health-Scrub trees/vegetation at the building
|
X
| |||
General/Health-Sleeping room(s) in the attic
| ||||
General/Health-Sleeping room(s) in the cellar/basement
| ||||
General/Health-Standing water in the building
|
X
| |||
General/Health-Substandard apartment unit
|
X
| |||
General/Health-Unacceptable repair(s)
|
X
| |||
General/Health-Unsanitary conditions in a dwelling/unit
|
X
| |||
General/Health-Unsanitary conditions-animal feces
|
X
| |||
General/Health-Work being performed without required permit(s)
|
X
| |||
Gutters-Deteriorated gutters/downspouts
|
X
| |||
Gutters-Incomplete gutter system
|
X
| |||
Gutters-Inoperable gutter(s)/gutter system
|
X
| |||
Gutters-Lack of downspouts
|
X
| |||
Gutters-Lack of gutter(s)/gutter system
|
X
| |||
Interior Walls-Deteriorated/improper/missing wall covering(s)
|
X
| |||
Interior Walls -Deteriorated/missing wall plaster/drywall/sheetrock
|
X
| |||
Interior Walls-Deteriorated/peeling interior paint
|
X
| |||
Mechanical-Condition of gas-fired appliance(s) is questionable
|
X
| |||
Mechanical-Deteriorated masonry fireplace
|
X
| |||
Mechanical-Deteriorated/missing gas-fired appliance inspection
cover/panel
| ||||
Mechanical-Deteriorated/missing gas-fired appliance vent pipe(s)
|
X
| |||
Mechanical-Deteriorated/missing heat duct(s)/register(s)
|
X
| |||
Mechanical-Failure to provide an inspection report
|
X
| |||
Mechanical-Gas-fired appliance vent piping improperly connected
to the chimney
|
X
| |||
Mechanical-Gas-fired appliance(s) in a bathroom(s)
|
X
| |||
Mechanical-Gas-fired appliance(s) in a sleeping room(s)
|
X
| |||
Mechanical-Gas-fired heating appliance failed inspection
|
X
| |||
Mechanical-Gas/fuel fired appliance/device no longer in use
|
X
| |||
Mechanical-Improper gas supply line material
|
X
| |||
Mechanical-Improper gas-fired appliance vent pipe rise
|
X
| |||
Mechanical-Improper maintenance of a gas-fired appliance
|
X
| |||
Mechanical-Improper use of flexible gas line/appliance connector
|
X
| |||
Mechanical-Improper venting of a gas-fired appliance(s)
|
X
| |||
Mechanical-Improper/missing gas shut-off valve(s)
|
X
| |||
Mechanical-Improperly installed gas supply line(s)
|
X
| |||
Mechanical-Improperly supported gas/water piping
|
X
| |||
Mechanical-Lack of combustion air supplied to a gas-fired appliance
|
X
| |||
Mechanical-Lack of gas service to dwelling(s)/unit(s)
|
X
| |||
Mechanical-Lack of/improper relief valve drip leg
|
X
| |||
Mechanical-Lack of/inadequate heat supplied to a habitable space
|
X
| |||
Mechanical-Leaking/deteriorated radiator(s) and/or radiator
supply line(s)
|
X
| |||
Mechanical-Leaking/inoperable boiler(s)
|
X
| |||
Mechanical-Leaking/inoperable water heater(s)
|
X
| |||
Mechanical-Missing gas supply line drip leg
|
X
| |||
Mechanical-Missing gas supply line(s) cap/plug
|
X
| |||
Mechanical-Missing/improper fireplace/appliance hearth
|
X
| |||
Mechanical-Missing/improper temperature/pressure relief valve(s)
|
X
| |||
Mechanical-Missing/inoperable carbon monoxide (CO) detector(s)
|
X
| |||
Mechanical-Missing/inoperable thermostat
|
X
| |||
Plumbing-system is questionable
|
X
| |||
Plumbing-Deteriorated bathtub/shower stall
|
X
| |||
Plumbing-Deteriorated/inoperable lavatory(s)/sink(s)
|
X
| |||
Plumbing-Deteriorated/inoperable/leaking toilet(s)
|
X
| |||
Plumbing-Deteriorated/leaking faucet(s)
|
X
| |||
Plumbing-Deteriorated/leaking waste line(s)
|
X
| |||
Plumbing-Deteriorated/leaking/improper potable water pipe(s)
|
X
| |||
Plumbing-Deteriorated/missing plumbing fixture component(s)
|
X
| |||
Plumbing-Deteriorated/missing plumbing fixture trap(s)
|
X
| |||
Plumbing-Directing/discharging sump pit water/ground w
|
X
| |||
Plumbing-Discharging sump pit water/ground water into the public
sanitary sewer
|
X
| |||
Plumbing-Dry plumbing fixture(s) and/or trap(s)
|
X
| |||
Plumbing-Flexible potable water line(s)/piping
| ||||
Plumbing-Improper termination of the plumbing system vent pipino/stack
| ||||
Plumbing-Improperly anchored lavatory(s)/sink(s)
|
X
| |||
Plumbing-Improperly installed fixture(s)/piping
|
X
| |||
Plumbing-Items hanging from/attached to water/gas piping and/or
electrical conduit
|
X
| |||
Plumbing-Lack of a 3-fixture bathroom
|
X
| |||
Plumbing-Lack of a kitchen sink
|
X
| |||
Plumbing-Lack of connection to a sanitary sewage system
|
X
| |||
Plumbing-Lack of hot/cold water supplied to a fixture(s)
|
X
| |||
Plumbing-Lack of water service to a dwelling(s)/unit(s)
|
X
| |||
Plumbing-Lack of/improper slope of drain piping/waste line(s)
|
X
| |||
Plumbing-Lack of/inoperable bathroom vent fan
|
X
| |||
Plumbing-Loose/improperly anchored toilet
|
X
| |||
Plumbing-Obstructed waste line(s)
|
X
| |||
Plumbing-Open waste line(s)
|
X
| |||
Plumbing-Open/uncovered sump pit
|
X
| |||
Porch-Deteriorated ceiling(s)
|
X
| |||
Porch-Deteriorated deck
|
X
| |||
Porch-Deteriorated floor joist(s)
|
X
| |||
Porch-Deteriorated porch(s)
|
X
| |||
Porch-Deteriorated/missing/improper porch/deck support(s)
|
X
| |||
Railing-Deteriorated guardrail(s)/guardrail balusters
|
X
| |||
Railing-Deteriorated/missing/improper handrail(s) for steps
|
X
| |||
Railing-Improper guardrail height
|
X
| |||
Railing-Improper handrail height
|
X
| |||
Railing-Improper separation of guardrail baluster(s)
|
X
| |||
Railing-Lack of handrail(s)-yard steps
|
X
| |||
Railing-Missing guardrail(s) and/or baluster(s)
|
X
| |||
Roof-Deteriorated/missing fascia board(s)
|
X
| |||
Roof-Deteriorated/missing roof sheathing
|
X
| |||
Roof-Deteriorated/missing soffit/roof overhang
|
X
| |||
Roof-Deteriorated/missing/improper roof covering
|
X
| |||
Roof-Deteriorated/missing/improper roof flashing
|
X
| |||
Roof-Deteriorated/missing/improper roof structural components
|
X
| |||
Roof-Evidence of roof leakage(s)
|
X
| |||
Stairways-Deteriorated stair system landing/deck joist(s)
|
X
| |||
Stairways-Deteriorated yardstep(s)
|
X
| |||
Stairways-Deteriorated/improperly installed stair system stringer(s)
|
X
| |||
Stairways-Deteriorated/missing stair system decking and/or landing
decking
|
X
| |||
Stairways-Deteriorated/missing stair system riser(s)
|
X
| |||
Stairways-Deteriorated/missing stair system tread(s)
|
X
| |||
Stairways-Deteriorated/missing stair system(s)
|
X
| |||
Stairways-Deteriorated/missing/improper stair system support/support
post(s)
|
X
| |||
Stairways-Improper construction of a stair system(s)
|
X
| |||
Stairways-Improper rise height within a stair system(s)
|
X
| |||
Stairways-Inadequate stairway headroom clearance
|
X
| |||
Substandard-Deteriorated/missing doors/windows
|
X
| |||
Substandard-Failure to hold a valid Certificate of Compliance
|
X
| |||
Substandard-Failure to hold a valid Rental License
|
X
| |||
Substandard-Failure to provide access to a building(s)/unit(s)
|
X
| |||
Substandard-Fire damaged structure(s)
|
X
| |||
Substandard-Fire damaged structure(s) beyond feasible repair
|
X
| |||
Substandard-Substandard/tagged building(s)/unit(s)
|
X
| |||
Substandard-Vacant building(s)/unit(s)-inspection required
|
X
| |||
Substandard-Vacant/Unfinished/Nuisance building(s)
|
X
| |||
Tenant-Excessive accumulation of debris
|
X
| |||
Tenant-Improper storage in a utility room(s)/area(s)
|
X
| |||
Tenant-Improper storage of combustible material(s)
|
X
| |||
Tenant-Improper storage of flammable liquid(s)
|
X
| |||
Tenant-Improper use of portable unvented gas/oil-fired heating
device(s)
|
X
| |||
Tenant-Inoperable smoke/Carbon monoxide detector(s)
|
X
| |||
Tenant-Obstructed stair(s)/Exit(s)/Fire escape(s)
|
X
| |||
Tenant-Sleeping room(s) in the attic and/or cellar
|
X
| |||
Tenant-Unsanitary conditions within a dwelling(s)/unit(s)
|
X
| |||
Windows-not weather-tight
|
X
| |||
Windows-Broken/missing pane(s)
|
X
| |||
Windows-Deteriorated window(s)
|
X
| |||
Windows-Deteriorated/missing screens
|
X
| |||
Windows-Deteriorated/missing window frame/sill
|
X
| |||
Windows-Exterior window paint deteriorated/peeling/missing
|
X
| |||
Windows-Improper screen(s)
|
X
|
All areas of each dwelling governed by this code shall be inspected.
Should access not be obtained to all areas, a reinspection must be
scheduled and an additional fee may be charged for each subsequent
reinspection of accordance with the established fee schedule.
|
Dwelling Units per Tax Parcel
|
Excessive Response Threshold
|
---|---|
1-3
|
10
|
4-8
|
25
|
9-24
|
50
|
25 or more
|
75
|
Section 202. Definitions. Amended to add a definition for "building
official" and modify the definition of "code official" and "habitable
space":
Building Official. See "Code Official".
Code Official. The officer, officers, or other designated
authorities charged with the administration and enforcement of this
code, or a duly authorized representative.
Any reference to "building official" in this code
refers to "code official".
Habitable Space. Space in a structure for living,
sleeping, or eating. Bathrooms, toilet rooms, closets, halls, storage
or utility spaces, and similar areas are not considered habitable
spaces.
|
Section 302.3. Sidewalks And Driveways. Amended to read:
302.3. Sidewalks And Driveways. Sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be maintained in accordance with chapter 12 of the City of Davenport code of ordinances and the City of Davenports standards for defective sidewalks.
|
Section 302.4. Weeds. Amended to read:
302.4. Weeds. Premises and exterior property shall be maintained in accordance with section 8.14.015 of the City of Davenport code of ordinances.
|
Section 304.2. Protective Treatment. Amended to read:
304.2. Protective Treatment. Exterior surfaces,
including but not limited to, doors, door and window frames, cornices,
porches, trim, balconies, decks and fences, shall be maintained in
good condition. Exterior wood surfaces, other than decay-resistant
woods, shall be protected from the elements and decay by painting
or other protective covering or treatment. Peeling, flaking and chipped
paint shall be eliminated and surfaces repainted. Siding and masonry
joints, as well as those between the building envelope and the perimeter
of windows, doors and skylights, shall be maintained weather resistant
and water tight. Metal surfaces subject to rust or corrosion shall
be coated to inhibit such rust and corrosion. Oxidation stains and
rust shall be removed from exterior surfaces when oxidation stains
or rust compromises the function of the building component to perform
as designed. Surfaces designed for stabilization by oxidation are
exempt from this requirement.
|
Section 304.14. Insect Screens. Insert: May 1 to November 1.
|
Section 304.18.1. Doors. Amended to read:
304.18.1. Doors. Doors providing access to a dwelling
unit, rooming unit or housekeeping unit that is rented, leased or
let shall be equipped with a lock designed to be readily openable
from the side from which egress is to be made without the need for
keys, special knowledge or effort. Such locks shall be installed according
to the manufacturer's specifications and maintained in good working
order.
|
Section 305.3. Interior Surfaces. Amended to read:
305.3. Interior Surfaces.
A. Interior surfaces, including windows and doors,
shall be maintained in good, clean and sanitary condition. Peeling,
chipping, loose, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and other defective
surface conditions shall be corrected.
B. All residential properties receiving federal
assistance must be in compliance with the lead safe housing rule at
24 CFR 35 and the lead based paint poisoning prevention act at 42
U.S.C. § 4822. The owner of federally assisted units must
provide certification that the dwelling is in accordance with said
regulations. If the federally assisted unit was constructed prior
to 1978, upon occupancy a notice must be provided which outlines the
lead based paint regulations, the hazards of lead based paint poisoning,
the symptoms and treatment of lead poisoning, and the precautions
to be taken against lead poisoning.
C. All residential property must comply with the
residential lead-based paint hazard reduction act of 1992, requiring
the disclosure of known information on lead-based paint and lead-based
paint hazards before the sale or lease of certain housing built before
1978
|
Section 404.4.2. Deleted.
|
Section 404.4.3. Water Closet Accessibility. Amended to read
as follows:
404.4.3. Water Closet Accessibility. Every bedroom
in a dwelling unit shall have access to not less than one water closet
and lavatory located in the same story as the bedroom or an adjacent
story.
|
Section 602.3. Heat Supply. Insert: September 15 to May 15.
|
Section 602.4. Occupiable Work Spaces. Insert: September 15
to May 15. Section 602.5. Room Temperature Measurement. Amended to
read:
602.5. Room Temperature Measurement. The required
room temperatures shall be measured three feet above the floor, at
the inside wall.
|
Section 605.2. Receptacles. Amended to add:
Exception: In lieu of every habitable space in a
dwelling containing two separate and remote receptacle outlets, one
receptacle and a separate permanently installed light fixture is allowable.
|