| Application form and plans for completeness review (three copies). |
| Application form (15 copies). |
| Plats or plans (15 copies) signed and sealed by a N.J. Professional Engineer and folded into eighths with title block revealed. |
| Scale of not less than one inch equals 20 feet on one of the following standard sheet sizes (8 1/2 inches by 13 inches; 15 inches by 21 inches; 24 inches by 36 inches or 30 inches by 42 inches). |
| Key map no less than one inch equals 1,000 feet. |
| Name, title, address and telephone number of subdivider or developer. |
| Name, title, address and license number of the professional or professionals who prepared the plat or plan. |
| Name, title and address of the owner or owners of record. |
| Scale (written and graphic). |
| Date of original preparation and of each subsequent revision thereof and a list of specific revisions entered on each sheet. |
| Acreage figures, to the nearest tenth of an acre or square footage. |
| North arrow. |
| Certification that the applicant is the owner of the land or his properly authorized agent, or that the owner has given his consent under an option agreement. |
| Place for signature of the Chairperson and Secretary of the Planning Board. |
| Existing tax sheet number(s) and existing block and lot number(s) of the lot(s) to be subdivided or developed as they appear on the Borough Tax map, and the proposed block and lot numbers as provided by the Borough Tax Collector upon written request. |
| The zoning district in which the parcel is located together with the district boundaries included within the boundaries of the parcel or within 200 feet therefrom. |
| Photographs of the property, where necessary, to show any unusual topographic, environmental, or physical aspect of the site. This would include, but not be limited to, vegetation, natural drainageways, wetlands, and existing structures and improvements. |
| The location of existing and required setback lines, streets within 500 feet of the development, the location of existing and proposed buildings, watercourses, railroads, bridges, culverts, drain pipes, and all natural features such as sand dune areas and other vegetation. |
| The location of all proposed permanent monuments. |
| Plans and profiles showing proposed utility layouts (sanitary sewers, storm drains, water, gas, electric, etc.) showing feasible connections to existing or proposed utility systems. Locations of fire hydrants and street lights shall be established with the aid of the Borough Fire Protection Official and the Borough Engineer, respectively. |
| Each block and lot shall be numbered in accordance with the system of numbers which will ultimately be the numbers shown on the Borough Tax Map. |
| Where brook, stream channel, shoreline improvements are proposed or required, the plans for such improvement shall be approved by the State Department of Environmental Protection or the Cape May County Planning Board, where applicable. |
| All proposed lot lines, dimensioned in feet and tenths, and the approximate area of all lots in square feet as well as any open spaces proposed to be dedicated for public use. |
| When the development of the subdivision or improvements are contingent upon improvements outside the boundaries of said subdivision, information shall be supplied by the developer prior to Planning Board consideration for preliminary approval that the improvements outside the development are installed and will be available to the developer. |
| Any open spaces proposed to be dedicated for public use or playgrounds or other public purpose and the location and use of all such property shall be shown on the plat. |
| The names and addresses of all property owners within 200 feet of the extreme limits of the tract as shown on the most recent tax list prepared by the Borough Tax Collector. |
| The existing and proposed contours, referred to U.S. Coast and Geodetic Survey Datum; at a contour interval of not less than two feet. Existing contours are to be indicated by solid lines. Location of existing rock outcroppings, high points, water courses and drainageways, depressions, ponds, marshes, vegetation, wooded areas and other significant existing features. |
| The location and design of all signs, the size, nature of construction, height and orientation, including all identification signs, traffic and directional signs and arrows, free standing facade signs and time controls for sign lighting. |
| The location of all outdoor lighting (free standing or on building), the size, nature of construction, lumens, heights, area and direction of illumination, foot candles produced, typical manufacturer cuts illustrating style, and time controls proposed for outdoor lighting and display. |
| Where brook, stream channel or shoreline improvements are proposed, the following information shall be required: |
| a. | When a stream is proposed for alteration, improvement, or relocation or when a drainage structure or fill is proposed over, under, in or along a running stream, a report shall be submitted on the status of review by the State Department of Environmental Protection, Division of Water Resources. |
| b. | Cross sections of water courses and/or drainage swales at an appropriate scale showing the extent of flood plain, top of bank, normal water levels, and bottom elevations at locations required by the Borough Engineer. |
| c. | The location and extent of drainage and conservation easements; |
| d. | The location and type of adequate drainage provisions to reasonably reduce and minimize exposure to flood damage. |
| Plans for such improvements shall be approved by the State Department of Environmental Protection and/or the Cape May County Planning Board where applicable. |
| All proposed lot lines, dimensioned in feet and tenths, and the approximate area of all lots in square feet as well as acreage calculations for any open spaces proposed to be dedicated for public use. |
| Plans shall depict the location, design, and size of any on or off-site pedestrian parks and bicycle pathways, open space, common open space, plazas and recreation areas, or any other public use areas. |
| The location and species associations of all existing trees or groups of trees having a caliper of five inches or more measured three feet above the ground level. |
| All adopted Master Plan proposals affecting the proposed development. |
| Plans shall include the location, size, elevation, slope, and type of storm drainage structures, above or below grade, whether publicly or privately owned. Design calculations supporting the adequacy of proposed drainage structures and/or surface drainage shall be submitted. These designs shall depict storm water drainage on-site and off-tract, with manholes, inlets, pipe sizes, grades, inverts, and directions of flow. Locations of fire hydrants and street lights shall be established with the aid of the Borough Fire Protection Official and the Borough Engineer, respectively. |
| The proposed use or uses of the land, buildings, and structures. |
| Proposed solid waste and recycling. |
| All landscape strips, landscape buffers, and any deviation from requirements of this Ordinance shall be specifically shown. |
| For site plans, a survey map prepared by a licensed surveyor of New Jersey showing boundaries of the properties, line of all existing streets and roads, easements, rights-of-way, and areas dedicated to public use within 200 feet of the development. These shall be dimensioned and, where applicable, referenced as to direction. |
| Plans and plats shall reference any existing or proposed deed restrictions or exceptions concerning all or any portion of the parcel or plat. A copy of any protective covenants or deed restrictions applying to the land being subdivided or developed shall be submitted with the preliminary plat. |
| The distances measured along the right-of-way lines of existing streets abutting the property to the nearest intersection with other streets. |
| The quantitative aspects of the proposal such as number of units, square feet of construction, density, coverage, number of employees, number of residents and area of land, etc. Specifically identified on the site plan, in tabular form, shall be pertinent zoning data, indicating the bulk/area requirements of the zone in which the proposed development is located and how the proposed development responds to the zoning requirements. |
| The proposed buildings and structures and any existing structures to remain, with dimensions, setbacks, heights (in feet and stories), and first floor or grade elevations. Existing buildings and structures to be removed shall be indicated. Architectural or historic significance of any existing buildings to remain or to be removed shall be indicated. |
| The location and designs of any off-street parking areas, bicycle parking, service, trash or loading areas showing size and location of bays, aisles, barriers, landscaping, planters, maneuvering areas, and traffic patterns. |
| Plans, typical cross sections and details, center line profiles and tentative grades of all proposed streets and of existing streets abutting the tract based on USGS vertical datum or a more specified datum supplied by the Borough Engineer, including curbing, sidewalks, storm drains and drainage structures and utility service lines. Sight triangles, the radius of curb lines, and street sign locations shall be clearly indicated at all intersections. |
| All means of vehicular access to and egress and from the site onto public streets, showing the location of driveways and curb cuts, including the possible utilization of traffic signals, channelization, acceleration and deceleration lanes, additional width, and any other proposed device intended to control traffic. |
| Existing and proposed traffic patterns. |
| Traffic study including, but not limited to: |
| a. | Anticipated traffic volumes. |
| b. | Capacity of existing and proposed roadways. |
| c. | Traffic volume impact from other developments. |
| d. | Roadway network problems, e.g. unsafe intersections, turns, grades. |
| e. | Need for traffic signals and other improvements. |
| Photographs of any unusual topographic, environmental, historic, or physical aspect. |
| Sketches, plans, and photographs of other known similar developments. |
| Sketch of typical building elevations indicating type of materials to be used. |
| The proposed use or uses of the land, buildings, and structures. |
| Schedule of desired development time frame from Borough review function to completion and occupancy. |
| Proposals for soil erosion and sediment control as required by N.J.S.A. 4:24-39 et seq. |
| Scale model of proposed development. |
| Certification by the Borough Tax Collector that all taxes and assessments are paid to date. |
| Environmental Impact Statement. |
| Community Impact Statement. |