Mobile home park plans shall be processed in accordance with Article III, Plan Processing Procedures. The design of mobile home parks shall comply with applicable design standards of this chapter and Chapter 350, Zoning.
A. 
Source. Where feasible, all mobile home parks shall be connected to the public or a community water system. Feasibility shall be established in accordance with § 295-408. Additionally, all water supply systems shall be provided in accordance with § 295-611.
B. 
Connection. All mobile homes and service buildings shall be connected to a public or a community water supply system. Individual water riser pipes having an inside diameter of not less than 3/4 inches shall be provided for each mobile home stand and shall terminate no less than four inches above the ground.
C. 
Protection of water lines. Adequate provisions shall be made to protect water service lines from damage including a shut-off valve installed below the frost line at the curbline for each mobile home space.
D. 
Fire hydrants. Fire hydrants or yard hydrants shall be installed in accordance with the provisions of the Middle Department Association of Fire Underwriters and the Authority regulations, when applicable.
A. 
Approved system. All mobile home parks shall conform to § 295-611 with respect to establishing an acceptable sanitary sewage disposal facility.
B. 
Connection. Where feasible, all mobile homes and service buildings shall be connected to a public or community sewer system. Feasibility shall be established in accordance with § 295-408. Individual riser pipes having a minimum inside diameter of four inches shall be located on each mobile home lot and shall extend four inches above ground level. The sewer riser pipe shall be sealed with a securely fastened plug when the site is unoccupied. Positive surface drainage away from the plug shall be provided to ensure no infiltration of surface water will occur. All sewer lines shall be constructed with materials and by methods approved by the Sewer Authority and DEP.
C. 
Protection. Adequate provision shall be made to protect sanitary sewers from stormwater infiltration and damage.
A. 
Private streets shall be provided in the park as the principal traffic way, and each mobile home lot shall abut and have access to such a street.
B. 
All streets and access drives shall be designed and constructed in accordance with the requirements of Article VI, Design Standards.
A. 
Location. All mobile home parks shall have sidewalks and curbs along parking compounds and private streets, and from mobile home units to service buildings.
B. 
Construction. Sidewalks required by § 295-708A shall comply with the requirements of § 295-602L.
All streets, alleys and parking compounds shall be lighted to provide an average minimum two footcandle level of illumination at an elevation of three feet above the grade for the safe movement of pedestrians and vehicles at night. All lighting shall be so arranged as to reflect the light away from adjoining premises and public rights-of-way.
A. 
Solid waste disposal shall be the responsibility of the mobile home park operator and shall be performed in accordance with the requirements of DEP.
B. 
All solid waste shall be stored in dumpsters located throughout the facility, but in no case more than 300 feet from any unit served.