A. The provisions of the 2018 International Building Code, and Appendixes or portions thereof, except as excluded below, including Appendix with errata as published by the International Code Council, is for all intents and purposes adopted and incorporated by reference in this Chapter as if fully set forth herein, except insofar as the same may be in conflict with this Code of Ordinances, in which case the more restrictive provision shall apply, and except as stated, modified and supplemented in Subsection
(B) hereof.
B. The portions of the 2018 International Building Code identified as
Appendix A, Employee Qualifications; Appendix B, Board of Appeals,
Appendix C, Group U - Agricultural Buildings; Appendix D, Fire Districts;
Appendix E, Supplementary Accessibility Requirements; Appendix F,
Rodentproofing; Appendix G, Flood-resistant Construction; Appendix
H, Signs; Appendix J, Grading; Appendix K, Administrative Provisions;
Appendix L, Earthquake Recording Instrumentation; Appendix M, Tsunami-Generated
Flood Hazard; and Appendix N, Replicable Buildings, are not so included
herein by reference.
C. A copy of the 2018 International Building Code is on file and open
for inspection of the public in the office of the City Clerk of the
City of Excelsior Springs.
[R.O. 2012 §500.025; Ord. No. 98-4-1, 4-20-1998; Ord. No.
2000-10-4 §2, 10-9-2000; Ord. No. 05-6-2 §2, 6-6-2005; Ord. No. 2013-05-07 §2, 5-20-2013; Ord. No. 15-04-02 §1, 4-20-2015; Ord. No. 18-09-09, 9-4-2018; Ord. No. 21-09-02, 12-6-2021]
A. The provisions of the 2018 International Residential Code, as published by the International Code Council, regulating and controlling the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of one- and two-family dwellings and townhouses, is for all intents and purposes adopted and incorporated by reference in this Chapter as if fully set forth herein, except insofar as the same may be in conflict with this Code of Ordinances in which case the more restrictive provision shall apply, and except as stated, modified and supplemented in Subsection
(B) hereof.
B. The following provisions coinciding with provisions of the International
Residential Code supersede or delete, when indicated, the corresponding
provisions of the International Residential Code:
1.
The portions of the 2018 International Residential Code identified
as Appendix E, Manufactured Housing Used as Dwellings; Appendix H,
Patio Covers, and Appendix J, Existing Building and Structures, shall
be included.
2.
R313 Automatic Fire Sprinkler Systems. A builder of a one- or
two-family dwelling or townhouse shall offer to any purchaser on or
before the time of entering into the purchase contract the option,
at the purchaser's cost, to install or equip fire sprinklers in the
dwelling or townhouse. The purchaser shall have the right to choose
or decline to install a fire sprinkler system. This notification requirement
is provided in accordance with, and shall expire in conjunction with,
Section 67.219, RSMo.
3.
E3902.2 (Garage And Accessory Building Receptacles), Exception.
Receptacles utilizing the provisions of this exception shall be permanently
marked to indicate "[Type of equipment] Only-No GFCI Protection."
1.
A dedicated receptacle supplying only a garage door opener.
2.
A dedicated receptacle supplying only a refrigerator and/or
freezer.
4.
E3902.5 (Unfinished Basement Receptacles), Exception. Receptacles
utilizing the provisions of this exception shall be permanently marked
to indicate "[Type of equipment] Only - No GFCI Protection."
1.
A dedicated receptacle supplying only a permanently installed
fire alarm or burglar alarm system.
2.
A dedicated receptacle supplying only a sump pump.
3.
A dedicated receptacle supplying a refrigerator and/or freezer.
5.
E3902.16 Arc-Fault Circuit-Interrupter Protection. All branch
circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets
installed in bedrooms shall be protected by a combination type arc-fault
circuit interrupter installed to provide protection of the entire
branch circuit.
C. A copy of the 2018 International Residential Code is on file and
open for inspection of the public in the office of the City Clerk
of the City of Excelsior Springs.
[Ord. No. 2013-05-07 §3, 5-20-2013; Ord.
No. 21-09-02, 12-6-2021]
A. The
provisions of the 2018 International Existing Building Code, as published
by the International Code Council, is for all intents and purposes
adopted and incorporated by reference in this Chapter as if fully
set forth herein, except insofar as the same may be in conflict with
this Code of Ordinances in which case the more restrictive provision
shall apply.
B. A copy
of the 2018 International Existing Building Code is on file and open
for inspection of the public in the office of the City Clerk of the
City of Excelsior Springs.