Water wells, underground cisterns, and pump suction pipes shall be placed no closer than fifty feet (50') from property lines, with minimum well construction requirements met or up to five feet (5') from property lines if the annular space is 3 inches larger than the outside diameter of the casing and pressure cemented or grouted from 100 feet back to the surface or from the top of the water production zone, whichever is shallower; fifty feet (50') from septic tanks; one hundred feet (100') from soil absorption systems or spray areas with minimum well construction specifications met; or twenty feet (20') from a sewer pipe with watertight joints. Provided that public water wells shall be permitted no closer than one hundred fifty feet (150') from any septic tank or fifty feet (50') from any stream, pond, or lake. Septic tanks or holding tanks which are designed for submergence (reinforced monolithic concrete, or equal) may be placed within twenty feet (20') of streams, ponds, water wells, and underground cisterns, provided the influent and effluent lines to and from the tank are constructed using watertight sewer pipe with compression or solvent welded joints.
(Ordinance 15-005 adopted 6/8/15)