This district is intended to accommodate the development of commercial enterprises exclusive of warehousing, manufacturing, storage and industrial uses, such as fabrication of materials and specialized manufacturing and research institutions, all of a non-nuisance type.
(1) 
Use regulations.
(A) 
Uses permitted in the "TC/LMI" district are outlined in the commercial, manufacturing and industrial use chart.
(B) 
Permitted uses shall not disseminate dust, fumes, gas, noxious odor, smoke, glare, or other atmospheric influence.
(C) 
Permitted uses shall produce no noise exceeding in intensity, at the boundary of the property, the average intensity of noise of street traffic.
(D) 
Machine shops and fabrication of metal of not more than ten (10) gauge in thickness.
(E) 
Residential use will follow single-family 1 (SF-1) district regulations.
(2) 
Area regulations.
(A) 
Size of yards.
(i) 
Minimum front yard: Thirty feet (30').
(ii) 
Minimum side yard: Ten feet (10').
(iii) 
Corner lot, street side yard (minimum): Twenty feet (20').
(iv) 
Minimum rear yard: Twenty-five feet (25').
(B) 
Size of lots.
(i) 
Minimum lot size: Twenty-five thousand (25,000) square feet.
(ii) 
Minimum lot width: One hundred fifty feet (150').
(iii) 
Minimum lot depth: One hundred fifty feet (150').
(C) 
Maximum height.
(i) 
[Deleted by Ordinance O-06-2022.]
(ii) 
HVAC equipment, roof gables, vent stakes and chimneys or mechanical rooms may project up to twelve feet (12') beyond maximum building height.
(D) 
Maximum lot coverage.
Seventy-five percent (75%).
(E) 
Minimum landscape area.
(i) 
Ten percent (10%).
(ii) 
See landscaping requirements.
(F) 
Minimum masonry coverage.
Fifty percent (50%) of exterior facade with exposure to a street, unless conforming to branded business franchise building standards.
(G) 
Parking regulations.
See off-street parking and loading standards.
(H) 
Other regulations.
[Reserved.]
(Ordinance O-02-2020, sec. 10-200, adopted 3/23/2020; 1997 Code, sec. 154.46; Ordinance O-06-2022 adopted 8/8/2022)
This district is intended to accommodate all types of industrial and warehousing uses, including oil and gas well servicing companies, and all other uses not prohibited by ordinance.
(1) 
Use regulations.
Uses permitted in the "MI" district are outlined in the commercial, manufacturing and industrial use chart.
(2) 
Area regulations.
(A) 
Size of yards.
(i) 
Minimum front yard: One hundred feet (100').
(ii) 
Minimum side yard: Fifty feet (50').
(iii) 
Corner lot, street side yard (minimum): Seventy-five feet (75').
(iv) 
Minimum rear yard: Fifty feet (50').
(B) 
Size of lots.
(i) 
Minimum lot size: Twenty-five thousand (25,000) square feet.
(ii) 
Minimum lot width: One hundred fifty feet (150').
(iii) 
Minimum lot depth: One hundred fifty feet (150').
(C) 
Maximum height.
(i) 
[Deleted by Ordinance O-06-2022.]
(ii) 
HVAC equipment, roof gables, vent stakes and chimneys or mechanical rooms may project up to twelve feet (12') beyond maximum building height.
(D) 
Maximum lot coverage.
Seventy-five percent (75%).
(E) 
Minimum landscape area.
(i) 
Ten percent (10%).
(ii) 
See landscaping requirements.
(F) 
Minimum masonry coverage.
Fifty percent (50%) of exterior facade with exposure to a street, unless conforming to branded business franchise building standards.
(G) 
Parking regulations.
See off-street parking and loading standards.
(H) 
Other regulations.
[Reserved.]
(Ordinance O-02-2020, sec. 10-300, adopted 3/23/2020; 1997 Code, sec. 154.47; Ordinance O-06-2022 adopted 8/8/2022)