A.
Lime.
The lime shall meet the requirements of TxDOT Item 264 for Type A - Hydrated Lime, Type B - Commercial Lime Slurry or Type C - Quicklime, Grade DS or S. Type C - Grade S, Quicklime shall not be used for dry placing.
B.
Water.
Water shall be reasonably clear without oil, salt, acid, alkali, organic matter, and other injurious substances. Water shall be tested in accordance with AASHTO T-26. The Engineer or the designated representative of the Engineer may elect to omit the test on the water if it is from a commonly known potable water source such as a public water supply system. All water shall meet with the approval of the Engineer or the designated representative of the Engineer regardless of the source.
C.
Equipment.
The equipment necessary for performing the work shall be on the project site prior to the beginning of construction operations. All machinery, tools and equipment shall be maintained in acceptable working condition. The Contractor shall conduct his operations in a workmanlike manner and shall use approved methods to perform the work.