Both the materials and the source of the supply must be approved by the Engineer or the designated representative of the Engineer prior to the delivery of any materials.
(Ordinance 2007-106, App. B, adopted 3/20/07)
Percent by Weight |
Passing the 3/8" sieve..... 100 |
Passing the No. 10 sieve..... 70-100 |
Passing the No. 200 sieve..... 0-15 |
Percent by Weight |
Passing a No. 30 sieve..... 95 to 100 |
Passing a No. 80 sieve, not less than..... 75 |
Passing a No. 200 sieve, not less than..... 55 |
ASPHALT CEMENT | ||
|---|---|---|
Viscosity Grade | AC-20 | |
Property | Min. | Max. |
Viscosity, | ||
140° F, poises | 1600 | 2400 |
275° F, poises | 2.5 | – |
Penetration,77°F | ||
100g, 5 sec | 55 | – |
Flash Point, C.O.C., F | 450 | – |
Solubility in Trichloroethylene, % | 99.0 | – |
Spot Test | Negative | |
Tests on Residue from Thin Film Oven Test: | ||
Viscosity, 140°F, poises | – | 6000 |
Ductility, 77°F,5 cm per min., cm | 70 | –- |
CUTBACK ASPHALT | ||||
|---|---|---|---|---|
Type-Grade | MC-30 | RC-250 | ||
Property | Min. | Max. | Min. | Max. |
Kinematic Viscosity @ 140° F, cst | 30 | 60 | 250 | 400 |
Water, percent | – | 0.2 | – | 0.2 |
Flash Point, T.O.C., F | 100 | – | 80 | – |
Distillation Test: Distillate, percentage by volume of total distillate to 680° F | ||||
to 437°F | – | 25 | 40 | 75 |
to 500°F | 40 | 70 | 65 | 90 |
to 600°F | 75 | 93 | 85 | – |
Residue from distillation, volume % | 50 | – | 70 | – |
Tests on Distillation Residue: | ||||
Penetration, 100 g, 5 sec., 77°F | 120 | 250 | 80 | 120 |
Ductility, 5 cm/min, 77°F, cm | 100* | – | 100 | – |
Solubility in Trichloroethylene, % | 99.0 | – | 99.0 | – |
Spot Test | Negative | Negative | ||
*If the penetration is more than 200 and the ductility at 77° F is less than 100 cm, the material will be acceptable if its ductility at 60° F is more than 100. |
ANIONIC EMULSIONS | ||
|---|---|---|
Type-Grade | SS-1 | |
Property | Min | Max |
Viscosity, Saybolt Furol at 77° F, sec | 20 | 100 |
Sieve Test, % | - | 0.10 |
Miscibilty (Standard Test) | Passing | |
Cement Mixing, % | - | 2.0 |
Storage Stability, 1 day, % | - | 1 |
Freezing Test, 3 cycles* | Passing | |
Distillation Test: | ||
Residue by Distillation, % by weight | 60 | - |
Oil Distillate, % by volume of emulsion | - | 1/2 |
Tests on Residue from Distillation: | ||
Penetration at 77°F, 100g, 5 sec | 120 | 160 |
Solubility in Trichlorethylene, % | 97.5 | - |
Ductility at 77° F, 5 cm/min, cm | 100 | - |
*Applies only when the material is designated for winter use. |
Density % | Stability % | ||
|---|---|---|---|
Min. | Max. | Optimum | Not Less Than |
95 | 99 | 96 | 35 |
Master Grading Requirements for the Aggregates | |
|---|---|
Sieve Sizes | Total Percent Passing, by Weight |
1-1/2 inch | – |
1-1/4 inch | – |
1-inch | 100% |
7/8 -inch | 95 - 100% |
5/8 -inch | 75 - 95% |
1/2-inch | – |
3/8 -inch | 60 - 80% |
1/4-inch | – |
No. 4 | 40 - 60% |
No. 10 | 27 - 40% |
No. 40 | 10 - 25% |
No. 80 | 3 - 13% |
No. 200 | 1 - 6%* |
VMA % Minimum | 12 |
*2 - 8 when Test Method Tex-200-F, Part II (Washed Sieve Analysis) is used. |
Master Grading Requirements for the Aggregates. | |
|---|---|
Sieve Sizes | Total Percent Passing, by Weight |
1-1/2 - inch | – |
1-1/4 - inch | – |
1 - inch | –- |
7/8 - inch | –- |
5/8 - inch | –- |
1/2 - inch | 100% |
3/8 - inch | 85 - 100% |
1/4 - inch | –- |
No. 4 | 50 - 70% |
No. 10 | 32 - 42% |
No. 40 | 11 - 26% |
No. 8 | 04 - 14% |
No. 200 | 1 - 6%* |
VMA % Minimum | 14 |
*2–8 when Test Method Tex-200-F, Part II (Washed Sieve Analysis) is used. |